Feedforward control method for single-phase inverters with non-linear load

被引:3
作者
You, Jiang [1 ]
Vilathgamuwa, Mahinda [2 ]
Ghasemi, Negareh [2 ]
Meng, Fanrong [1 ]
机构
[1] Harbin Engn Univ, Coll Automat, Harbin, Heilongjiang, Peoples R China
[2] Queensland Univ Technol, Sch Elect Engn & Comp Sci, Brisbane, Qld, Australia
基金
中国国家自然科学基金;
关键词
harmonic distortion; electric current control; invertors; feedforward; rectifiers; PI control; predictive control; inverter voltage distortion; pulsating load current; basic inverter control structure; repetitive controller; synchronous reference frame PI controller; PCFF method; single-phase inverter performance; total harmonics distortion; output voltage quality; feedforward control method; single-phase inverters; nonlinear rectifier loads; heavy distortion; pulsating charging current; rectifier direct current link capacitor; predictive load current-based digital feedforward compensation method; REPETITIVE CONTROL; VOLTAGE; DESIGN;
D O I
10.1049/iet-pel.2018.5273
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Non-linear rectifier loads usually cause heavy distortion in the output voltage of single-phase inverters due to pulsating charging current of the rectifier direct current link capacitor. In this article, a predictive load current-based digital feedforward (PCFF) compensation method is proposed to decrease the inverter voltage distortion associated with the pulsating load current. PCFF control scheme works along with the basic inverter control structure that consists of a repetitive controller and a synchronous reference frame PI controller. The PCFF method further improves the single-phase inverter performance by enhancing its compensation dynamics. The simulation and experimental results show that the proposed control strategy can effectively reduce the total harmonics distortion of the inverter voltage and improve the output voltage quality.
引用
收藏
页码:3131 / 3140
页数:10
相关论文
共 26 条
[1]  
Bommegowda KB, 2015, PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON POWER AND ADVANCED CONTROL ENGINEERING (ICPACE), P418, DOI 10.1109/ICPACE.2015.7274984
[2]  
Cai HD, 2014, IEEE INT FUZZY SYST, P707, DOI 10.1109/FUZZ-IEEE.2014.6891682
[3]  
Chattopadhyay R, 2014, IEEE ENER CONV, P3634, DOI 10.1109/ECCE.2014.6953895
[4]   Digital control of single-phase UPS inverters with modified PWM technique [J].
Deng, H ;
Oruganti, R ;
Srinivasan, D .
PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, :1365-1371
[5]   Repetitive. based controller for a UPS inverter to compensate unbalance and harmonic distortion [J].
Escobar, G. ;
Valdez, A. A. ;
Leyva-Ramos, J. ;
Mattavelli, P. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (01) :504-510
[6]   Direct Grid Current Control of LCL-Filtered Grid-Connected Inverter Mitigating Grid Voltage Disturbance [J].
Jia, Yaoqin ;
Zhao, Jiqian ;
Fu, Xiaowei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1532-1541
[7]   Low-THD, Fast-Transient, and Cost-Effective Synchronous-Frame Repetitive Controller for Three-Phase UPS Inverters [J].
Jiang, Shuai ;
Cao, Dong ;
Li, Yuan ;
Liu, Jianfeng ;
Peng, Fang Zheng .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (06) :2994-3005
[8]  
Komurcugil H, 2014, IEEE IND ELEC, P1305, DOI 10.1109/IECON.2014.7048670
[9]   Decoupling Voltage Controller Design with Time Response Specifications for Three-Phase DC/AC Inverter [J].
Lee, Jinmok ;
Choi, Jaeho .
2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, :630-+
[10]  
Lim K, 2017, 2017 IEEE 3RD INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE AND ECCE ASIA (IFEEC 2017-ECCE ASIA), P1920, DOI 10.1109/IFEEC.2017.7992343