Application of contrast-enhanced ultrasonography and ultrasonography scores in rheumatoid arthritis

被引:5
|
作者
Cai, Xiao-Han [1 ]
Yang, Shu-Ping [1 ]
Shen, Hao-Lin [1 ]
Lin, Li-Qing [1 ]
Zhong, Rong [1 ]
Wu, Rui-Ming [1 ]
Lv, Guo-Rong [1 ]
机构
[1] Fujian Med Univ, Affiliated Zhangzhou Hosp, Dept Ultrasound, Zhangzhou 363000, Fujian, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2015年 / 8卷 / 11期
关键词
Rheumatoid arthritis; Contrast-enhanced ultrasonography; ultrasonography scores; Joint; synovial; C-REACTIVE PROTEIN; DISEASE-ACTIVITY; JOINT; ANTIBODIES; KNEE;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To investigate diagnostic value of ultrasonography scores (US) and contrast-enhanced ultrasonography (CEUS) in evaluating rheumatoid arthritis (RA) activity. Methods: 39 patients with RA were included and the metacarpophalangeal, proximal interphalangeal, wrist, elbow and knee joints of them were examined by high frequency ultrasound. The severe joints and the related indexes (synovial thickness, synovial blood flow, joint effusion and bone erosion) were exposed. Then scores (0 similar to 3) were obtained and the sum was calculated. For 12 patients of the 39, 2.4 ml SonoVue was intravenously injected with observation of synovial enhancing. ROIs time-intensity curve (TIC) was obtained and the parameters including area under curve (AUC), peak intensity (PI) and time to peak (TTP) were analyzed. For 39 patients, the relationships among each parameters, ultrasonography scores, DAS28 scores and biochemical examinations (ESR, CRP, RF, anti-CCP) were analyzed. Results: The US were significantly correlated with DAS28 Scores (r = 0.823, P < 0.01=. The correlation between US and CRP was better than that between DAS28 scores and CRP (rUS = 0.692, rDAS28 = 0.526, P < 0.01). The synovial thickness in US were correlated with DAS28 Scores and biochemical examinations (ESR, CRP) (rDAS28 = 0.852, rESR = 0.779, rCRP = 0.587, P < 0.01. The AUC and PI in CEUS were significantly correlated with US (r(AUC) = 0.832, r(PI) = 0.809, P < 0.01=. The correlations among AUC, PI and ESR were better than that between US and ESR (rAUC = 0.907, rPI = 0.851, rUS = 0.836, P < 0.01=. The correlations among AUC, PI and CRP were better than that between US and CRP (rAUC = 0.855, rPI = 0.854, rUS= 0.692, P < 0.01. Conclusions: US was almost identical with DAS28 Scores and biochemical examinations (ESR, CRP) in diagnosis of RA activity, while CEUS was almost identical with DAS28 Scores and biochemical examinations (ESR, CRP). In diagnosis of RA, US may be better than DAS28 Scores, while CEUS better than US. Both of them were useful for evaluation of RA activity.
引用
收藏
页码:20056 / 20064
页数:9
相关论文
共 50 条
  • [22] Contrast-enhanced ultrasonography with Sonazoid for evaluation of renal microcirculation
    Satoshi Okayama
    Toshiko Hirai
    Namiko Yamashita
    Satoshi Somekawa
    Masayuki Iwano
    Shiro Uemura
    Masao Kanauchi
    Yoshihiko Saito
    Journal of Medical Ultrasonics, 2008, 35 : 183 - 189
  • [23] Bleeding in abdominal cavity revealed by contrast-enhanced ultrasonography
    Shuichi Sato
    Hiroshi Tobita
    Tatsuya Miyake
    Tsukasa Saitou
    Yoshikazu Kinoshita
    Journal of Medical Ultrasonics, 2013, 40 : 289 - 291
  • [24] A case of eosinophilic cholangitis: Imaging findings of contrast-enhanced ultrasonography, cholangioscopy, and intraductal ultrasonography
    Matsumoto, Naoki
    Yokoyama, Kiyoshi
    Nakai, Kazuhiko
    Yamamoto, Toshiki
    Otani, Takeshi
    Ogawa, Masahiro
    Tanaka, Naohide
    Iwasaki, Ariyoshi
    Arakawa, Yasuyuki
    Sugitani, Masahiko
    WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (13) : 1995 - 1997
  • [25] Bleeding in abdominal cavity revealed by contrast-enhanced ultrasonography
    Sato, Shuichi
    Tobita, Hiroshi
    Miyake, Tatsuya
    Saitou, Tsukasa
    Kinoshita, Yoshikazu
    JOURNAL OF MEDICAL ULTRASONICS, 2013, 40 (03) : 289 - 291
  • [26] Contrast-enhanced ultrasonography in postoperative renal tumor imaging
    Stamatiou, K.
    Moschouris, I
    Tzamarias, S.
    Zavradinos, D.
    Fokas, K.
    Zioutos, K.
    Politis, V
    SCIENTIFIC CHRONICLES, 2018, 23 (03) : 386 - 399
  • [27] Contrast-enhanced ultrasonography with Sonazoid for diagnosis of gangrenous cholecystitis
    Ryousuke Kawai
    Jiro Hata
    Noriaki Manabe
    Hiroshi Imamura
    Ai Iida
    Rui Nakatou
    Nobuko Koyama
    Toshihiro Hirai
    Yoshito Sadahira
    Journal of Medical Ultrasonics, 2016, 43 : 193 - 199
  • [28] Contrast-enhanced ultrasonography in the diagnosis of solid renal tumors
    Tamai, H
    Takiguchi, Y
    Oka, M
    Shingaki, N
    Enomoto, S
    Shiraki, T
    Furuta, M
    Inoue, I
    Iguchi, M
    Yanaoka, K
    Arii, K
    Shimizu, Y
    Nakata, H
    Shinka, T
    Sanke, T
    Ichinose, M
    JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (12) : 1635 - 1640
  • [29] Contrast-enhanced ultrasonography with Sonazoid for evaluation of renal microcirculation
    Okayama, Satoshi
    Hirai, Toshiko
    Yamashita, Namiko
    Somekawa, Satoshi
    Iwano, Masayuki
    Uemura, Shiro
    Kanauchi, Masao
    Saito, Yoshihiko
    JOURNAL OF MEDICAL ULTRASONICS, 2008, 35 (04) : 183 - 189
  • [30] Contrast-enhanced ultrasonography with Sonazoid™ for the evaluation of bowel ischemia
    Tomoko Kanzaki
    Jiro Hata
    Hiroshi Imamura
    Noriaki Manabe
    Kazuhide Okei
    Hiroaki Kusunoki
    Tomoari Kamada
    Akiko Shiotani
    Ken Haruma
    Journal of Medical Ultrasonics, 2012, 39 : 161 - 167