Immediate postpartum intrauterine device and implant program outcomes: a prospective analysis

被引:29
作者
Eggebroten, Jennifer L. [1 ]
Sanders, Jessica N. [1 ]
Turok, David K. [1 ]
机构
[1] Univ Utah, Dept Obstet & Gynecol, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
contraception; contraceptive implant; immediate postpartum intrauterine device insertion; intrauterine device expulsion; removals; RANDOMIZED-CONTROLLED-TRIAL; POSTPLACENTAL INSERTION; REVERSIBLE CONTRACEPTION; ETONOGESTREL IMPLANT; PROSPECTIVE COHORT; CESAREAN DELIVERY; VAGINAL DELIVERY; WOMEN; CONTINUATION; LEVONORGESTREL;
D O I
10.1016/j.ajog.2017.03.015
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BACKGROUND: In-hospital placement of intrauterine devices and contraceptive implants following vaginal and cesarean delivery is increasingly popular and responds to maternal motivation for highly effective postpartum contraception. Immediate postpartum intrauterine device insertion is associated with higher expulsion than interval placement, but emerging evidence suggests that the levonorgestrel intrauterine device may have a higher expulsion rate than the copper intrauterine device. OBJECTIVE: This study evaluated in-hospital provision, expulsion, and 6-month continuation of immediate postpartum copper T380 intrauterine devices, levonorgestrel intrauterine devices, and contraceptive implants. STUDY DESIGN: We offered enrollment in this prospective observational trial to women presenting to the University of Utah labor and delivery unit from October 2013 through February 2016 who requested an intrauterine device or implant for postpartum contraception during prenatal care or hospitalization at the time of delivery. Following informed consent, participants completed questionnaires prior to hospital discharge and at 3 and 6 months postpartum. Data on expulsions at 6 months were validated by chart abstraction. RESULTS: During the study period, 639 patients requested a postpartum intrauterine device or implant and 350 patients enrolled in prospective follow-up prior to discharge from the hospital. Among enrollees, 325 (93%) received their preferred contraceptive device prior to hospital discharge: 88 (27%) copper intrauterine device users, 123 (38%) levonorgestrel intrauterine device users, and 114 (35%) implant users. Participants predominantly were Hispanic (90%), were multiparous (87%), reported a household income<$24,000 per year (87%), and underwent a vaginal delivery (77%). At 6 months postpartum, 289 of 325 device recipients (89%) completed follow-up. Among levonorgestrel intrauterine device users 17% reported expulsions relative to 4% of copper intrauterine device users. The adjusted hazard ratio for expulsion was 5.8 (confidence interval, 1.3-26.4). There was no statistically significant difference in expulsions by delivery type or continuation by device type. Among the 21 women who experienced intrauterine device expulsions, 14 (67%) requested a replacement long-acting reversible contraception device for contraception. The 6-month device continuation was >= 80% for all device types. CONCLUSION: An immediate postpartum long-acting reversible contraception program effectively provides women who desire highly effective reversible contraceptive devices with their method of choice prior to hospital discharge. Immediate postplacental levonorgestrel intrauterine device users have higher expulsion rates than copper intrauterine device users, but >8 of 10 women initiating an intrauterine device or implant continue use at 6 months postpartum.
引用
收藏
页码:51.e1 / 51.e7
页数:7
相关论文
共 31 条
[1]  
[Anonymous], 2016, Obstet Gynecol, V128, P422, DOI 10.1097/AOG.0000000000001583
[2]  
[Anonymous], 2015, COCHRANE DB SYST REV
[3]   CHARACTERISTICS AND DETERMINANTS OF POSTPARTUM OVARIAN-FUNCTION IN WOMEN IN THE UNITED-STATES [J].
CAMPBELL, OMR ;
GRAY, RH .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (01) :55-60
[4]   Clinical outcomes of early postplacental insertion of intrauterine contraceptive devices [J].
Çelen, S ;
Möröy, P ;
Sucak, A ;
Aktulay, A ;
Danisman, N .
CONTRACEPTION, 2004, 69 (04) :279-282
[5]   Immediate postplacental insertion of an intrauterine contraceptive device during cesarean section [J].
Celen, Sevki ;
Sucak, Ayhan ;
Yildiz, Yasemin ;
Danisman, Nuri .
CONTRACEPTION, 2011, 84 (03) :240-243
[6]   Postplacental or Delayed Insertion of the Levonorgestrel Intrauterine Device After Vaginal Delivery A Randomized Controlled Trial [J].
Chen, Beatrice A. ;
Reeves, Matthew F. ;
Hayes, Jennifer L. ;
Hohmann, Heather L. ;
Perriera, Lisa K. ;
Creinin, Mitchell D. .
OBSTETRICS AND GYNECOLOGY, 2010, 116 (05) :1079-1087
[7]  
CHI I-C, 1989, Advances in Contraception, V5, P127, DOI 10.1007/BF01849356
[8]   Twelve-month contraceptive continuation and repeat pregnancy among young mothers choosing postdelivery contraceptive implants or postplacental intrauterine devices [J].
Cohen, Rebecca ;
Sheeder, Jeanelle ;
Arango, Natalia ;
Teal, Stephanie B. ;
Tocce, Kristina .
CONTRACEPTION, 2016, 93 (02) :178-183
[9]   Effects of birth spacing on maternal health:: a systematic review [J].
Conde-Agudelo, Agustin ;
Rosas-Bermudez, Anyeli ;
Kafury-Goeta, Ana C. .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 196 (04) :297-308
[10]   IMMEDIATE POSTPLACENTAL IUD PLACEMENT AFTER CESAREAN AND VAGINAL DELIVERIES AT AN ACADEMIC TRAINING CENTER [J].
Curry, C. L. ;
Iverson, R. ;
Rindos, N. ;
Sonalkar, S. .
CONTRACEPTION, 2012, 86 (02) :176-176