Vascular complications of liver transplantation: Evaluation with gadolinium-enhanced MR angiography

被引:71
|
作者
Stafford-Johnson, DB
Hamilton, BH
Dong, Q
Cho, KJ
Turcotte, JG
Fontana, RJ
Prince, MR
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Med Ctr, Dept Transplant Surg, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Med Ctr, Dept Gastroenterol, Ann Arbor, MI 48109 USA
关键词
gadolinium; liver; transplantation; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.207.1.9530311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate use of gadolinium-enhanced magnetic resonance (MR) angiography in detection of vascular complications of liver transplantation. MATERIALS AND METHODS: Thirteen liver transplant recipients suspected to have vascular complications were evaluated with gadolinium-enhanced MR angiography by using a three-dimensional spoiled gradient-echo breath-hold technique during the arterial and venous phases of;a high-dose (42 mt) bolus injection of gadolinium contrast material. Conventional angiography (n = 11) and surgery (n = 3) were used as the standard of reference. The transplant hepatic artery, celiac trunk, superior mesenteric artery, portal vein, superior mesenteric Vein, splenic vein. hepatic veins, and inferior vena cava (IVC) were evaluated for thrombosis or stenosis is by two radiologists. RESULTS: Ten vascular complications were identified with conventional angiography or surgery: transplant hepatic artery thrombosis (n = 3) or stenosis (n = 3), portal vein stenosis (n = 1) or occlusion (n = 2), and suprahepatic IVC stenosis n = 1, All 10 complications were correctly diagnosed with MR angiography. There was agreement between results of MR angiography and conventional angiography or surgery In 58 of 62 vessels evaluated (94%). There was minor disagreement in four vessels (6%). CONCLUSION: Three-dimensional gadolinium-enhanced MR angiography may have the potential to enable accurate diagnosis of Vascular Complications of liver transplantation.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [1] Potential renal transplant donors: Evaluation with gadolinium-enhanced MR angiography and MR urography
    Low, RN
    Martinez, AG
    Steinberg, SM
    Alzate, GD
    Kortman, KE
    Bower, BB
    Dwyer, WJ
    Prince, SK
    RADIOLOGY, 1998, 207 (01) : 165 - 172
  • [2] Percutaneous vascular intervention based on gadolinium-enhanced MR angiography
    Sharafuddin, MJA
    Wroblicka, JT
    Sun, SL
    Essig, M
    Schoenberg, SO
    Yuh, WTC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (06) : 739 - 746
  • [3] Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography
    Rofsky, NM
    Johnson, G
    Adelman, MA
    Rosen, RJ
    Krinsky, GA
    Weinreb, JC
    RADIOLOGY, 1997, 205 (01) : 163 - 169
  • [4] Gadolinium-enhanced MR angiography of the carotid arteries
    Enochs, WS
    Ackerman, RH
    Kaufman, JA
    Candia, M
    JOURNAL OF NEUROIMAGING, 1998, 8 (04) : 185 - 190
  • [5] Renal artery stenosis: Evaluation with conventional angiography versus gadolinium-enhanced MR angiography
    Gilfeather, M
    Yoon, HC
    Siegelman, ES
    Axel, L
    Stolpen, AH
    Shlansky-Goldberg, RD
    Baum, RA
    Soulen, MC
    Schnall, MD
    RADIOLOGY, 1999, 210 (02) : 367 - 372
  • [6] Determination of optimal injection parameters for intraarterial gadolinium-enhanced MR angiography
    Frayne, R
    Omary, RA
    Unal, O
    Strother, CM
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (10) : 1277 - 1284
  • [7] Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography
    Kim, JK
    Farb, RI
    Wright, GA
    RADIOLOGY, 1998, 206 (01) : 283 - 289
  • [8] GADOLINIUM-ENHANCED MR AORTOGRAPHY
    PRINCE, MR
    RADIOLOGY, 1994, 191 (01) : 155 - 164
  • [9] Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography
    Davis, CP
    Hany, TF
    Wildermuth, S
    Schmidt, M
    Debatin, JF
    RADIOGRAPHICS, 1997, 17 (05) : 1061 - 1077
  • [10] Thoracic aorta: Comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging
    Krinsky, GA
    Rofsky, NM
    DeCorato, DR
    Weinreb, JC
    Earls, JP
    Flyer, MA
    Galloway, AC
    Colvin, SB
    RADIOLOGY, 1997, 202 (01) : 183 - 193