A pilot study of high-adsorption hemofiltration in human septic shock

被引:34
作者
Haase, M.
Silvester, W.
Uchino, S.
Goldsmith, D.
Davenport, P.
Tipping, P.
Boyce, N.
Bellomo, R.
机构
[1] Univ Melbourne, Intens Care Unit, Austin Hosp, Heidelberg, Vic 3084, Australia
[2] Monash Med Ctr, Dept Med, Melbourne, Vic, Australia
[3] Univ Melbourne, Australian Red Cross Blood Serv, Melbourne, Vic, Australia
关键词
cytokines; hemofiltration; septic shock; interleukin-6; interleukin-10; multiorgan failure;
D O I
10.1177/039139880703000205
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: To compare the hemodynamic and biological effects of high-adsorption continuous veno-venous hemofiltration (CVVH) with standard CVVH in septic shock. Methods: In a randomized cross-over clinical trial twelve patients with septic shock and multiple organ failure were enrolled at a tertiary intensive care unit. Patients were allocated to either 9 hours of high-adsorption hemofiltration (CVVH with 3 hourly filter change using AN69 hemofilters-3F-CVVH) or 9 hours of standard hemofiltration (CVVH without filter change-1F-CVVH). Results: Changes in hemodynamic variables, dose of noradrenaline required to maintain a mean arterial pressure greater than 75 mmHg and plasma concentrations of cytokines (IL-6, IL-8, IL-10 and IL-18) were measured. A 9-hour period of 3F-CVVH was associated with greater reduction in noradrenaline dose than a similar period of 1F-CVVH (median reduction: 16 vs. 3.5 mu g/min, p=0.036, median percentage reduction: 48.1% vs. 17.5%, p=0.028). Unlike 1F-CVVH, 3F-CVVH was associated with a reduction in the plasma concentration of IL-6, IL-10 and IL-18 at 9 hours and a significant decrease 30 minutes after additional filter changes (IL-6: p < 0.01, p < 0.01; IL-10: p=0.03, p=0.016 and IL-18: p=0.016, p < 0.01, respectively). Both, 3F-CVVH and 1F-CVVH were associated with decreased plasma concentrations of IL-8 at 9 hours (p < 0.01, p < 0.01, respectively). In a confirmatory ex-vivo experiment IL-6 concentrations substantially decreased during 3F-CVVH (at baseline 511pg/mL and at end: 21pg/mL) whereas IL-6 concentrations increased in control blood (at baseline 511pg/mL and at end: 932pg/mL). Conclusions: High-adsorption CVVH appears more effective than standard CVVH in decreasing noradrenaline requirements and plasma concentrations of cytokines in septic shock patients.
引用
收藏
页码:108 / 117
页数:10
相关论文
共 20 条
[1]   DEFINITIONS FOR SEPSIS AND ORGAN FAILURE AND GUIDELINES FOR THE USE OF INNOVATIVE THERAPIES IN SEPSIS [J].
BONE, RC ;
BALK, RA ;
CERRA, FB ;
DELLINGER, RP ;
FEIN, AM ;
KNAUS, WA ;
SCHEIN, RMH ;
SIBBALD, WJ .
CHEST, 1992, 101 (06) :1644-1655
[2]  
CAVAILLON JM, 1992, CIRC SHOCK, V38, P145
[3]   A phase II randomized, controlled trial of continuous hemofiltration in sepsis [J].
Cole, L ;
Bellomo, R ;
Hart, G ;
Journois, D ;
Davenport, P ;
Tipping, P ;
Ronco, C .
CRITICAL CARE MEDICINE, 2002, 30 (01) :100-106
[4]   High-volume haemofiltration in human septic shock [J].
Cole, L ;
Bellomo, R ;
Journois, D ;
Davenport, P ;
Baldwin, I ;
Tipping, P .
INTENSIVE CARE MEDICINE, 2001, 27 (06) :978-986
[5]  
De Vriese AS, 1999, J AM SOC NEPHROL, V10, P846
[6]  
Gasche Y, 1996, NEPHROL DIAL TRANSPL, V11, P117
[7]   THE ROLE OF HEMOFILTRATION IN THE CRITICALLY-III INTENSIVE-CARE UNIT PATIENT - PRESENT AND FUTURE [J].
GROOTENDORST, AF ;
VANBOMMEL, EFH .
BLOOD PURIFICATION, 1993, 11 (04) :209-223
[8]   Cytokine removal and cardiovascular hemodynamics in septic patients with continuous venovenous hemofiltration [J].
Heering, P ;
Morgera, S ;
Schmitz, FJ ;
Schmitz, G ;
Willers, R ;
Schultheiss, HP ;
Strauer, BE ;
Grabensee, B .
INTENSIVE CARE MEDICINE, 1997, 23 (03) :288-296
[9]   Effect of hemofiltration filter adsorption on circulating IL-6 levels in septic rats [J].
Kellum, JA ;
Dishart, MK .
CRITICAL CARE, 2002, 6 (05) :429-433
[10]   Continuous renal replacement therapies: An update [J].
Manns, M ;
Sigler, MH ;
Teehan, BP .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 32 (02) :185-207