Spectral interferences in the determination of rhenium in molybdenum and copper concentrates by inductively coupled plasma optical emission spectrometry (ICP-OES)

被引:19
作者
Karadjov, Metody [1 ]
Velitchkova, Nikolaya [1 ]
Veleva, Olga [1 ]
Velichkov, Serafim [2 ]
Markov, Pavel [2 ]
Daskalova, Nonka [2 ]
机构
[1] Bulgarian Acad Sci, Inst Geol, Acad G Bontchev Str,Bl 24, Sofia 1113, Bulgaria
[2] Bulgarian Acad Sci, Inst Gen & Inorgan Chem, Acad G Bontchev Str,Bl 24, Sofia 1113, Bulgaria
关键词
ICP-OES; Rhenium; Spectral interferences; Detection limits; Cu and Mo concentrates; SEPARATION; EXTRACTION; ELEMENTS; SAMPLES; FUSION; ROCK;
D O I
10.1016/j.sab.2016.03.011
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This paper deals with spectral interferences of complex matrix containing Mo, Al, Ti, Fe, Mg, Ca and Cu in the determination of rhenium in molybdenum and copper concentrates by inductively coupled plasma optical emission spectrometry (ICP-OES). By radial viewing 40.68 MHz ICP equipped with a high resolution spectrometer (spectral bandwidth = 5 pm) the hyperfine structure (HFS) of the most prominent lines of rhenium (Re II 197.248 nm, Re II 221.426 nm and Re II 227.525 nm) was registered. The HFS components under high resolution conditions were used as separate prominent line in order to circumvent spectral interferences. The Q-concept was applied for quantification of spectral interferences. The quantitative databases for the type and the magnitude of the spectral interferences in the presence of above mentioned matrix constituents were obtained by using a radial viewing 40.68 MHz ICP with high resolution and an axial viewing 27.12 MHz ICP with middle resolution. The data for the both ICP-OES systems were collected chiefly with a view to spectrochemical analysis for comparing the magnitude of line and wing (background) spectral interference and the true detection limits with spectroscopic apparatus with different spectral resolution. The sample pretreatment methods by sintering with magnesium oxide and oxidizing agents as well as a microwave acid digestion were applied. The feasibility, accuracy and precision of the analytical results were experimentally demonstrated by certified reference materials. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 33 条
[1]   Selective rhenium recovery from spent reforming catalysts [J].
Angelidis, TN ;
Rosopoulou, D ;
Tzitzios, V .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (05) :1830-1836
[2]  
Boumans P.M.J.M., 1987, INDUCTIVELY COUPLE 1, P358
[3]   Extraction and determination of trace amounts of rhenium in plants [J].
Bozhkov, OD ;
Borisova, LV .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (02) :135-141
[4]   Axially and radially viewed inductively coupled plasmas - a critical review [J].
Brenner, IB ;
Zander, AT .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (08) :1195-1240
[5]  
Buinovsky A.S., 2007, P NEWS POLYTECHNIC U, V311, P92
[6]  
Burch Robert., 1978, Platinum Metals Review, V22, P57
[7]   SUPERCONDUCTIVITY OF RHENIUM [J].
DAUNT, JG ;
SMITH, TS .
PHYSICAL REVIEW, 1952, 88 (02) :309-311
[8]  
Doerffel K., 1984, STAT ANAL CHEM
[9]  
Emsley J., 2001, NATURES BUILDING BLO, P358
[10]  
Evdokimova O.V., 2010, WORKSH P 9 ISR RUSS, P14