Dynamics Reconstruction of Remote Photoplethysmography

被引:0
作者
He, Lin [1 ]
Alam, Kazi Shafiul [1 ]
Ma, Jiachen [1 ]
Povinelli, Richard [1 ]
Ahamed, Sheikh Iqbal [1 ]
机构
[1] Marquette Univ, Milwaukee, WI 53233 USA
来源
PERVASIVE COMPUTING TECHNOLOGIES FOR HEALTHCARE, PERVASIVE HEALTH 2021 | 2022年 / 431卷
关键词
Remote photoplethysmography; Phase space reconstruction; Heart rate; Heart rate variability;
D O I
10.1007/978-3-030-99194-4_8
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Photoplethysmography based medical devices are widely used for cardiovascular status monitoring. In recent years, many algorithms have been developed to achieve cardiovascular monitoring results comparable to the medical device from remote photoplethysmography (rPPG). rPPG is usually collected from the region of interest of the subject face and has been used for heart rate detection. Though there were many works on the study of chaos dynamics of PPG, very few are on the characteristics of the rPPG signal. The main purpose of this study is to discover rPPG dynamics from nonlinear signal processing techniques, which may provide insight for improving the accuracy of cardiovascular status monitoring. Univ. Bourgogne Franche-Comt ' e Remote Photo-PlethysmoGraphy dataset is used for the experiment. The results show rPPG is considered as chaotic. The best-estimated embedding dimension for the rPPG signal is between 3 to 4. The time delay is 10 for an interpolated 240 Hz rPPG signal. The interpolation process will increase the complexity level and reduce the correlation dimension of the rPPG. The bandpass filtering process will reduce the complexity level and the correlation dimension of the rPPG. Introducing the features derived from reconstructed phase space such as Lyanpunov exponent, correlation dimension and approximate entropy, could improve the accuracy of heart rate variability detection from rPPG.
引用
收藏
页码:96 / 110
页数:15
相关论文
共 50 条
[41]   A Novel Framework for Remote Photoplethysmography Pulse Extraction on Compressed Videos [J].
Zhao, Changchen ;
Lin, Chun-Liang ;
Chen, Weihai ;
Li, Zhengguo .
PROCEEDINGS 2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS (CVPRW), 2018, :1380-1389
[42]   Pulse Rate Variability Analysis Using Remote Photoplethysmography Signals [J].
Yu, Su-Gyeong ;
Kim, So-Eui ;
Kim, Na Hye ;
Suh, Kun Ha ;
Lee, Eui Chul .
SENSORS, 2021, 21 (18)
[43]   Remote Photoplethysmography Is an Accurate Method to Remotely Measure Respiratory Rate: A Hospital-Based Trial [J].
Allado, Edem ;
Poussel, Mathias ;
Renno, Justine ;
Moussu, Anthony ;
Hily, Oriane ;
Temperelli, Margaux ;
Albuisson, Eliane ;
Chenuel, Bruno .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (13)
[44]   Remote photoplethysmography with constrained ICA using periodicity and chrominance constraints [J].
Macwan, Richard ;
Benezeth, Yannick ;
Mansouri, Alamin .
BIOMEDICAL ENGINEERING ONLINE, 2018, 17
[45]   Depression Recognition Using Remote Photoplethysmography From Facial Videos [J].
Casado, Constantino Alvarez ;
Canellas, Manuel Lage ;
Lopez, Miguel Bordallo .
IEEE TRANSACTIONS ON AFFECTIVE COMPUTING, 2023, 14 (04) :3305-3316
[46]   Remote photoplethysmography with constrained ICA using periodicity and chrominance constraints [J].
Richard Macwan ;
Yannick Benezeth ;
Alamin Mansouri .
BioMedical Engineering OnLine, 17
[47]   Robust and Remote Photoplethysmography Based on Smartphone Imaging of the Human Palm [J].
Lian, Chao ;
Yang, Yiming ;
Yu, Xiaodong ;
Sun, Hui ;
Zhao, Yuliang ;
Zhang, Guanglie ;
Li, Wen Jung .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
[48]   Remote photoplethysmography device with adaptive illumination for skin microcirculation assessment [J].
Kviesis-Kipge, Edgars ;
Rubins, Uldis .
BIOPHOTONICS-RIGA 2020, 2020, 11585
[49]   Remote photoplethysmography for skin perfusion monitoring using narrowband illumination [J].
Marcinkevics, Z. ;
Rubins, U. ;
Aglinska, A. ;
Caica, A. ;
Grabovskis, A. .
CLINICAL AND PRECLINICAL OPTICAL DIAGNOSTICS II, 2019, 11073
[50]   Remote Photoplethysmography System for Unsupervised Monitoring Regional Anesthesia Effectiveness [J].
Rubins, U. ;
Miscuks, A. ;
Marcinkevics, Z. ;
Lange, M. .
BIOPHOTONICS-RIGA 2017, 2017, 10592