Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates: V. Effects of electrode surface area

被引:16
作者
Huang, CQ [1 ]
Shepherd, RK [1 ]
机构
[1] Univ Melbourne, Dept Otolaryngol, CRC Cochlear Implant & Hearing Aid Innovat, Melbourne, Vic 3002, Australia
关键词
auditory nerve; high rate electrical stimulation; electrically evoked auditory brainstem response; cochlear implant; large surface area electrode; charge density;
D O I
10.1016/S0378-5955(00)00100-3
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
High rate intracochlear electrical stimulation at high intensities can induce significant reductions in the excitability of the auditory nerve as measured by a decrement in the amplitude of the electrically evoked auditory brainstem response (EABR). Such changes are primarily associated with stimulus induced neuronal activity, although direct current (DC) can also contribute. We examined the extent of stimulus induced change in auditory nerve excitability using large surface area platinum electrodes ('high-Q' electrodes). These electrodes have a surface area similar to 70 times greater than standard Pt electrodes of the same geometric area, resulting in lower DC and charge density (charge/electrode surface area) for a common stimulus. Guinea pigs were bilaterally implanted with either high-Q or standard Pt electrodes, and unilaterally stimulated for 2 h using stimulus intensities of 12 dB or 20-30 dB above EABR threshold (0.34 mu C/phase) at stimulus rates of 200, 400, or 1000 pulses per second (pps). EABRs were recorded before and following the acute stimulation. While there were significant reductions in EABR amplitudes and elevated EABR thresholds following stimulation at 12 dB above threshold using 400 and 1000 pps delivered to standard Pt electrodes, there were fewer or no significant changes in the post-stimulus EABR amplitude and threshold using high-Q electrodes under equivalent stimulus conditions. At a higher stimulus intensity (20-30 dB above EABR threshold), no reduction in EABR amplitude was observed at 200 pps for both stimulating electrodes. However, EABRs were reduced significantly at 400 and 1000 pps. There was significantly greater EABR recovery following stimulation using high-Q electrodes compared with standard Pt electrodes at 400 (P<0.05) and 1000 pps (P < 0.05). These data indicate that large surface area electrodes can significantly reduce stimulus induced changes in auditory nerve excitability, and may therefore have important clinical application. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:57 / 71
页数:15
相关论文
共 60 条
[1]  
Agnew W F, 1975, Surg Neurol, V4, P438
[2]  
Agnew W. F., 1990, NEURAL PROSTHESES FU, P225
[3]   HISTOPATHOLOGIC EVALUATION OF PROLONGED INTRACORTICAL ELECTRICAL-STIMULATION [J].
AGNEW, WF ;
YUEN, TGH ;
MCCREERY, DB ;
BULLARA, LA .
EXPERIMENTAL NEUROLOGY, 1986, 92 (01) :162-185
[4]   MORPHOLOGIC CHANGES AFTER PROLONGED ELECTRICAL-STIMULATION OF THE CATS CORTEX AT DEFINED CHARGE-DENSITIES [J].
AGNEW, WF ;
YUEN, TGH ;
MCCREERY, DB .
EXPERIMENTAL NEUROLOGY, 1983, 79 (02) :397-411
[5]   LOCAL-ANESTHETIC BLOCK PROTECTS AGAINST ELECTRICALLY-INDUCED DAMAGE IN PERIPHERAL-NERVE [J].
AGNEW, WF ;
MCCREERY, DB ;
YUEN, TGH ;
BULLARA, LA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (04) :301-308
[6]   ELECTROPHYSIOLOGICAL STUDIES OF LONG-TERM ELECTRICAL-STIMULATION OF CEREBELLUM IN MONKEYS [J].
BABB, TL ;
SOPER, HV ;
LIEB, JP ;
BROWN, WJ ;
OTTINO, CA ;
CRANDALL, PH .
JOURNAL OF NEUROSURGERY, 1977, 47 (03) :353-365
[7]  
Black R C, 1983, Acta Otolaryngol Suppl, V399, P5
[8]   POSTTETANIC EXCITABILITY CHANGES AND ECTOPIC DISCHARGES IN A HUMAN MOTOR AXON [J].
BOSTOCK, H ;
BERGMANS, J .
BRAIN, 1994, 117 :913-928
[9]   TISSUE-REACTIONS TO LONG-TERM ELECTRICAL-STIMULATION OF CEREBELLUM IN MONKEYS [J].
BROWN, WJ ;
BABB, TL ;
SOPER, HV ;
LIEB, JP ;
OTTINO, CA ;
CRANDALL, PH .
JOURNAL OF NEUROSURGERY, 1977, 47 (03) :366-379
[10]   ELECTRICAL-STIMULATION WITH PT ELECTRODES .2. ESTIMATION OF MAXIMUM SURFACE REDOX (THEORETICAL NON-GASSING) LIMITS [J].
BRUMMER, SB ;
TURNER, MJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1977, 24 (05) :440-443