Base-load thermoelectric power generation using evacuated tube solar collector and water storage tank

被引:21
作者
Faraji, Amir Yadollah [1 ]
Date, Abhijit [1 ]
Singh, Randeep [2 ]
Akbarzadeh, Aliakbar [1 ]
机构
[1] RMIT Univ, Renewable Energy Grp, Sch Aero Mech & Manuf Engn, Melbourne, Vic, Australia
[2] Fujikura Ltd, R&D Dept, Thermal Technol Div, Koto Ku, Tokyo 1358512, Japan
来源
2013 ISES SOLAR WORLD CONGRESS | 2014年 / 57卷
关键词
Base-load electricity generation; thermoelectric; evacuated tube solar collector; thermal storage;
D O I
10.1016/j.egypro.2014.10.178
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The concept of using low temperature solar heated water to produce electricity is not new but so far very few attempts have been made to produce continuous power (24 hours - 7days) from low grade solar thermal systems. In this study we are looking at continuous electricity production during not only sunny days but also night times and or cloudy days. Thermoelectric technology has a good potential for reliable electricity generation form low temperature heat source like solar heated hot water. A series of "electricity generation apparatus inside thermoelectric" abbreviated as ELEGANT have been designed and fabricated and the latest, ELEGANT-24 which produces almost 22 W(e) and comprises 24 market-available Peltier module, operating as generator, successfully operated for two months. Eight evacuated tube solar collectors are used to heat the water up and then store into an insulated storage tank during day time. In this period ELEGANT-24 uses outlet hot water of solar collectors, as a source of heat. Cold water from a non-insulated storage tank passes ELEGANT-24 in as coolant and gets preheated and then enters the solar collectors thru same non-insulated tank. This pre-heated water entered into the collector helps to improve the overall energy conversion efficiency of the whole system. Through this process heat is converted to electricity with minimum heat loss. This process can be continued during night time while hot water is supplied through circulating of insulated storage tank. As well as addressing base load power production, above configuration dramatically increases the efficiency of heat to electricity conversion via thermoelectric technology. This is due to that dissipated heat from cold side of TEGs would not be wasted and goes back to the heating circle. It means that except very small heat loss through walls of ELEGANT-24 and piping, there is no other heat loss.
引用
收藏
页码:2112 / +
页数:2
相关论文
共 11 条
[1]  
Brandstetter A., 1974, HOT DEEPS RED SEA PO, P277
[2]   STUDIES OF A THERMOELECTRIC GENERATOR OPERATING FROM TUBULAR SOLAR COLLECTORS [J].
DURST, T ;
HARRIS, LB ;
GOLDSMID, HJ .
SOLAR ENERGY, 1983, 31 (04) :421-425
[3]  
Goldsmid H.J., 2005, THERMOELECTRICS HDB
[4]   Advances in solar thermal electricity technology [J].
Mills, D .
SOLAR ENERGY, 2004, 76 (1-3) :19-31
[5]   Experimental study on low-temperature waste heat thermoelectric generator [J].
Niu, Xing ;
Yu, Jianlin ;
Wang, Shuzhong .
JOURNAL OF POWER SOURCES, 2009, 188 (02) :621-626
[6]  
Rawe D. M., 2005, THERMOELECTRICS HDB
[7]   Thermoelectrics: a review of present and potential applications [J].
Riffat, SB ;
Ma, XL .
APPLIED THERMAL ENGINEERING, 2003, 23 (08) :913-935
[8]  
Rowe D M, 2012, MODULES SYSTEMS APPL, P581
[9]  
Rowe D. M., 1998, NEDO CARDIFF THERMOE, P18
[10]   Evaluation of thermoelectric modules for power generation [J].
Rowe, DM ;
Min, G .
JOURNAL OF POWER SOURCES, 1998, 73 (02) :193-198