Real-Time Detection of Incipient Inter-Turn Short Circuit and Sensor Faults in Permanent Magnet Synchronous Motor Drives Based on Generalized Likelihood Ratio Test and Structural Analysis

被引:11
作者
Hasan Ebrahimi, Saeed [1 ]
Choux, Martin [1 ]
Huynh, Van Khang [1 ]
机构
[1] Univ Agder, Dept Engn Sci, N-4879 Grimstad, Norway
关键词
fault diagnosis; inter-turn short circuit; sensor fault; structural analysis; generalized likelihood ratio test; PM synchronous motor; STATOR SHORT CIRCUITS; BRUSHLESS DC MOTORS; RESIDUAL GENERATORS; DIAGNOSIS; PMSM; IDENTIFICATION; MACHINE; FDI;
D O I
10.3390/s22093407
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a robust model-based technique to detect multiple faults in permanent magnet synchronous motors (PMSMs), namely inter-turn short circuit (ITSC) and encoder faults. The proposed model is based on a structural analysis, which uses the dynamic mathematical model of a PMSM in an abc frame to evaluate the system's structural model in matrix form. The just-determined and over-determined parts of the system are separated by a Dulmage-Mendelsohn decomposition tool. Subsequently, the analytical redundant relations obtained using the over-determined part of the system are used to form smaller redundant testable sub-models based on the number of defined fault terms. Furthermore, four structured residuals are designed based on the acquired redundant submodels to detect measurement faults in the encoder and ITSC faults, which are applied in different levels of each phase winding. The effectiveness of the proposed detection method is validated by an in-house test setup of an inverter-fed PMSM, where ITSC and encoder faults are applied to the system in different time intervals using controllable relays. Finally, a statistical detector, namely a generalized likelihood ratio test algorithm, is implemented in the decision-making diagnostic system resulting in the ability to detect ITSC faults as small as one single short-circuited turn out of 102, i.e., when less than 1% of the PMSM phase winding is short-circuited.
引用
收藏
页数:22
相关论文
共 46 条
[21]   Current-Based Inter-Turn Short Circuit Fault Modeling in Permanent Magnet Synchronous Machine using Magnetic Equivalent Circuit Model [J].
Faiz, Jawad ;
Exiri, A. H. ;
Nejadi-Koti, H. .
2016 10TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING (CPE-POWERENG), 2016, :265-270
[22]   Inter-Turn Short Circuit Diagnosis of Permanent Magnet Synchronous Motor Based on Siamese Convolutional Neural Network Under Small Fault Samples [J].
Wu, Xiang ;
Geng, Yanfeng ;
Li, Minglei ;
Wang, Weiliang ;
Tu, Mengyu .
IEEE SENSORS JOURNAL, 2024, 24 (16) :26982-26993
[23]   A Diagnosis Method for Inter-turn Short-circuit Fault of A Nine-phase Permanent Magnet Synchronous Motor Based on Search Coil [J].
Lv, Xinyang ;
Zheng, Xiaoqin .
2022 25TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2022), 2022,
[24]   Fault coil location of inter-turn short-circuit for direct-drive permanent magnet synchronous motor using knowledge graph [J].
Lv, Ke ;
Gao, Caixia ;
Si, Jikai ;
Feng, Haichao ;
Cao, Wenping .
IET ELECTRIC POWER APPLICATIONS, 2020, 14 (09) :1712-1721
[25]   Fault detection of synchronous motor inter-turn short circuit based on current residual harmonic characteristics [J].
Yuan, Junyao ;
Dong, Xun ;
Niu, Gang ;
Ge, Xiaocheng .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2025,
[26]   Real-Time Hardware-in-the-Loop Simulation of Permanent-Magnet Synchronous Motor Drives Under Stator Faults [J].
Alvarez-Gonzalez, Fernando ;
Griffo, Antonio ;
Sen, Bhaskar ;
Wang, Jiabin .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (09) :6960-6969
[27]   Detection of Stator Winding Inter-Turn Short Circuit Faults in Permanent Magnet Synchronous Motors and Automatic Classification of Fault Severity via a Pattern Recognition System [J].
Cira, Ferhat ;
Arkan, Muslum ;
Gumus, Bilal .
JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2016, 11 (02) :416-424
[28]   Fault-tolerant torque control of a three-phase permanent magnet synchronous motor with inter-turn winding short circuit [J].
Forstner, G. ;
Kugi, A. ;
Kemmetmueller, W. .
CONTROL ENGINEERING PRACTICE, 2021, 113
[29]   Inter-Turn Short-Circuit Fault Detection Approach for Permanent Magnet Synchronous Machines Through Stray Magnetic Field Sensing [J].
Liu, Xuyang ;
Miao, Wenchao ;
Xu, Qi ;
Cao, Libing ;
Liu, Chunhua ;
Pong, Philip W. T. .
IEEE SENSORS JOURNAL, 2019, 19 (18) :7884-7895
[30]   Detection and Compensation of Inter-turn Short Circuit in Interior Permanent Magnet Synchronous Machines with 2-level Voltage Source Inverter [J].
Palavicino, Pablo Castro ;
Lee, Woongkul ;
Sarlioglu, Bulent .
2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, :4460-4465