Correlation between Myocardial Function and Electric Current Pulsatility of the Sputnik Left Ventricular Assist Device: In-Vitro Study

被引:5
作者
Telyshev, Dmitry V. [1 ,2 ]
Pugovkin, Alexander A. [1 ]
Ephimov, Ivan A. [1 ]
Markov, Aleksandr [2 ]
Leonhardt, Steffen [3 ]
Walter, Marian [3 ]
Karimov, Jamshid H. [4 ]
Selishchev, Sergey V. [1 ]
机构
[1] Natl Res Univ Elect Technol, Inst Biomed Syst, Moscow 124498, Russia
[2] IM Sechenov First Moscow State Med Univ, Inst Bion Technol & Engn, Moscow 119991, Russia
[3] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, D-52074 Aachen, Germany
[4] Cleveland Clin, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 08期
关键词
heart failure; left ventricular assist device; myocardial function; mechanical circulatory support; ROTARY BLOOD PUMP; CARDIAC POWER OUTPUT; FLOW ESTIMATION; PHYSIOLOGICAL CONTROL; HEART; CONTROLLER; PARAMETERS; RECOVERY; DESIGN; INDEX;
D O I
10.3390/app11083359
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study assesses the electric current parameters and reports on the analysis of the associated degree of myocardial function during left ventricular assist device (LVAD) support. An assumption is made that there is a correlation between cardiac output and the pulsatility index of the pump electric current. The experimental study is carried out using the ViVitro Pulse Duplicator System with Sputnik LVAD connected. Cardiac output and cardiac power output are used as a measure of myocardial function. Different heart rates (59, 73, 86 bpm) and pump speeds (7600-8400 rpm in 200 rpm steps) are investigated. In our methodology, ventricular stroke volumes in the range of 30-80 mL for each heart rate at a certain pump speed were used to simulate different levels of contractility. The correlation of the two measures of myocardial function and proposed pulsatility index was confirmed using different correlation coefficients (values >= 0.91). Linear and quadratic models for cardiac output and cardiac power output versus pulsatility index were obtained using regression analysis of measured data. Coefficients of determination for CO and CPO models were in the ranges of 0.914-0.982 and 0.817-0.993, respectively. Study findings suggest that appropriate interpretation of parameters could potentially serve as a valuable clinical tool to assess myocardial therapy using LVAD infrastructure.
引用
收藏
页数:15
相关论文
共 58 条
[1]   Non-invasive flow estimation in an implantable rotary blood pump: a study considering non-pulsatile and pulsatile flows [J].
Ayre, PJ ;
Lovell, NH ;
Woodard, JC .
PHYSIOLOGICAL MEASUREMENT, 2003, 24 (01) :179-189
[2]  
Boes S., 2018, HYDRAULIC CHARACTERI
[3]   Hydraulic Characterization of Implantable Rotary Blood Pumps [J].
Boes, Stefan ;
Thamsen, Bente ;
Haas, Mattia ;
Daners, Marianne Schmid ;
Meboldt, Mirko ;
Granegger, Marcus .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (06) :1618-1627
[4]   LVAD-Induced reverse remodeling: Basic and clinical implications for myocardial recovery [J].
Burkhoff, D ;
Klotz, S ;
Mancini, DM .
JOURNAL OF CARDIAC FAILURE, 2006, 12 (03) :227-239
[5]   Thromboresistance Comparison of the HeartMate II Ventricular Assist Device With the Device Thrombogenicity Emulation-Optimized HeartAssist 5 VAD [J].
Chiu, Wei-Che ;
Girdhar, Gaurav ;
Xenos, Michalis ;
Alemu, Yared ;
Soares, Joao S. ;
Einav, Shmuel ;
Slepian, Marvin ;
Bluestein, Danny .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (02)
[6]  
Choi S, 2005, INT J CONTROL AUTOM, V3, P100
[7]   A sensorless approach to control of a turbodynamic left ventricular assist system [J].
Choi, S ;
Antaki, JF ;
Boston, JR ;
Thomas, D .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2001, 9 (03) :473-482
[8]   Hemodynamic controller for left ventricular assist device based on pulsatility ratio [J].
Choi, Seongjin ;
Boston, J. Robert ;
Antaki, James F. .
ARTIFICIAL ORGANS, 2007, 31 (02) :114-125
[9]   Role of cardiac power in heart failure [J].
Cotter, G ;
Williams, SG ;
Vered, Z ;
Tan, LB .
CURRENT OPINION IN CARDIOLOGY, 2003, 18 (03) :215-222
[10]   A safe automatic driving method for a continuous flow ventricular assist device based on motor current pulsatility:: in vitro evaluation [J].
Endo, G ;
Araki, K ;
Oshikawa, M ;
Kojima, K ;
Nakamura, K ;
Matsuzaki, Y ;
Onitsuka, T .
ASAIO JOURNAL, 2002, 48 (01) :83-89