Quantification of airway diameters and 3D airway tree rendering from dynamic hyperpolarized 3He magnetic resonance imaging

被引:30
作者
Lewis, TA
Tzeng, YS
McKinstry, EL
Tooker, AC
Hong, KS
Sun, YP
Mansour, J
Handler, Z
Albert, MS
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
关键词
hyperpolarized 3He MRI; asthma; airway tree;
D O I
10.1002/mrm.20349
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As another step toward extracting quantitative information from hyperpolarized He-3 MRI, airway diameters in humans were measured from projection images and multislice images of the lungs. Values obtained were in good agreement with the Weibel lung morphometry model. The measurement of airway caliber can now be achieved without the use of ionizing radiation. Furthermore, it was demonstrated that 3D airway tree renderings could be constructed from the multislice data. Both the measurement of airway diameters and the rendering of 3D airway information hold promise for the clinical assessment of bronchoconstrictive diseases such as asthma and the associated evaluation of treatment effectiveness. Work is being done to address the uncertainties of the manually intensive methods we have developed.
引用
收藏
页码:474 / 478
页数:5
相关论文
共 21 条
[11]  
Johnson GA, 2001, MAGN RESON MED, V45, P365, DOI 10.1002/1522-2594(200103)45:3<365::AID-MRM1047>3.0.CO
[12]  
2-0
[13]   Normal and abnormal pulmonary ventilation: Visualization at hyperpolarized He-3 MR imaging [J].
Kauczor, HU ;
Hofmann, D ;
Kreitner, KF ;
Nilgens, H ;
Surkau, R ;
Heil, W ;
Potthast, A ;
Knopp, MV ;
Otten, EW ;
Thelen, M .
RADIOLOGY, 1996, 201 (02) :564-568
[14]   A three-dimensional model of the human airway tree [J].
Kitaoka, H ;
Takaki, R ;
Suki, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (06) :2207-2217
[15]   Alveolar tissue inflammation in asthma [J].
Kraft, M ;
Djukanovic, R ;
Wilson, S ;
Holgate, ST ;
Martin, RJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (05) :1505-1510
[16]   OPTIMIZATION OF COMPUTED-TOMOGRAPHY TECHNIQUE TO DEMONSTRATE THE FINE-STRUCTURE OF THE LUNG [J].
MURATA, K ;
KHAN, A ;
ROJAS, KA ;
HERMAN, PG .
INVESTIGATIVE RADIOLOGY, 1988, 23 (03) :170-175
[17]   Dynamic spiral MRI of pulmonary gas flow using hyperpolarized 3He:: Preliminary studies in healthy and diseased lungs [J].
Salerno, M ;
Altes, TA ;
Brookeman, JR ;
de Lange, EE ;
Mugler, JP .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :667-677
[18]   Study of the three-dimensional geometry of the central conducting airways in man using computed tomographic (CT) images [J].
Sauret, V ;
Halson, RM ;
Brown, IW ;
Fleming, JS ;
Bailey, AG .
JOURNAL OF ANATOMY, 2002, 200 (02) :123-134
[19]   Distal airways in humans:: Dynamic hyperpolarized 3He MR imaging -: Feasibility [J].
Tooker, AC ;
Hong, KS ;
McKinstry, EL ;
Costello, P ;
Jolesz, FA ;
Albert, MS .
RADIOLOGY, 2003, 227 (02) :575-579
[20]   3D airway segmentation via hyperpolarized 3He gas MRI by using scale-based fuzzy connectedness [J].
Wang, BQ ;
Saha, PK ;
Udupa, JK ;
Ferrante, MA ;
Baumgardner, J ;
Roberts, DA ;
Rizi, RR .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2004, 28 (1-2) :77-86