Development and validation of a dissolution test method for vitamin A in dietary supplement tablets

被引:11
作者
Davydova, Natalia [1 ]
Stippler, Erika [1 ]
Jin, Ping [1 ]
Giancaspro, Gabriel [1 ]
机构
[1] US Pharmacopeia, Rockville, MD 20852 USA
关键词
Dissolution test; Vitamin A tablets; Retinyl acetate; Retinyl palmitate; Reverse phase HPLC; Dietary supplements; LIQUID-CHROMATOGRAPHY;
D O I
10.1016/j.jpba.2010.03.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A dissolution test method and an analytical procedure by HPLC were developed and validated for evaluation of the dissolution behavior of dietary supplements tablets containing vitamin A in the forms of retinyl acetate or retinyl palmitate. Seven different commercially available products containing retinyl acetate or retinyl palmitate were selected for this study. A dissolution medium containing 1% (w/v) Octoxynol 9 (Triton X-100) and 1% (w/v) (+)-sodium alpha-ascorbate in 005 M phosphate buffer, pH 68, was found suitable to ensure sink conditions and chemical stability for both retinyl acetate and retinyl palmitate Two rotation speeds, 50 and 75 rpm, were evaluated with USP Apparatus 2 and 900 ml dissolution medium. Dissolution profiles were generated over 120 min Dissolution samples were analyzed with a reversed-phase HPLC method with UV detection at 325 nm. Each product was also assayed for vitamin A content according to USP 32-NF 27. The results from 45 min to the last time point of the dissolution tests performed at 75 rpm were consistent with the Assay results The dissolution test described here could be proposed as a pharmacopeial standard to assess the performance of tablet formulations containing vitamin A as retinyl esters. (C) 2010 Elsevier B.V All rights reserved.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 12 条
[1]  
Brown CynthiaK., 2004, Pharmaceutical Technology, P56, DOI [10.14227/DT110204P28, DOI 10.14227/DT110204P28]
[2]   Simultaneous analysis of Vitamins A and E in infant milk-based formulae by normal-phase high-performance liquid chromatography-diode array detection using a short narrow-bore column [J].
Chavez-Servin, Jorge L. ;
Castellote, Ana I. ;
Lopez-Sabater, M. Carmen .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1122 (1-2) :138-143
[3]  
*COUNC EUR, 2009, EUR PHARM 6 5
[4]  
EITENMILLER R, 2008, VITAMIN ANAL HLTH FO, P16
[5]  
HUMAYOUN A, 2008, FOOD CHEM, V111, P255
[6]  
*I MED FOOD NUTR B, 2001, VIT A DIET REF INT V, P65
[7]   A rapid HPLC method used to establish pediatric reference intervals for vitamins A and E [J].
Johnson-Davis, Kamisha L. ;
Moore, Steve J. ;
Owen, William E. ;
Cutler, Jeaneah M. ;
Frank, Elizabeth L. .
CLINICA CHIMICA ACTA, 2009, 405 (1-2) :35-38
[8]  
MARTINDALE, 2005, COMPLETE DRUG REFERE, P1451
[9]   Analysis of all-in-one parenteral nutrition admixtures by liquid chromatography and laser diffraction: study of stability [J].
Sforzini, A ;
Bersani, G ;
Stancari, A ;
Grossi, G ;
Bonoli, A ;
Ceschel, GC .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (5-6) :1099-1109
[10]  
*USP, 2009, OIL WAT SOL VIT MIN, P1105