Effect of central hole location in phakic intraocular lenses on visual function under progressive headlight glare sources

被引:19
作者
Martinez-Plaza, Elena [1 ]
Lopez-Miguel, Alberto [1 ,3 ]
Fernandez, Itziar [1 ,2 ]
Blazquez-Arauzo, Francisco [1 ]
Maldonado, Miguel J. [1 ,3 ]
机构
[1] Univ Valladolid, Inst Oftalmobiol Aplicada, Valladolid, Spain
[2] Networking Res Ctr Bioengn Biomat & Nanomed, Valladolid, Spain
[3] Inst Salud Carlos III, Red Temat Invest Colaborat Oftalmol, Madrid, Spain
关键词
IMPLANTABLE COLLAMER LENS; QUALITY-OF-LIFE; HIGH MYOPIA; MODERATE; ICL;
D O I
10.1016/j.jcrs.2019.06.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the effect of the central hole location in the V4c implantable collamer lens (ICL) on the quality of vision, including progressive headlight glare simulation and quality of life. Setting: IOBA-Eye Institute, Valladolid, Spain. Design: Case series. Methods: The central hole location was determined by slitlamp and dual Scheimpflug imaging for 6 months or more postoperatively. The visual acuity, mesopic contrast sensitivity, halogen glare contrast sensitivity, xenon glare contrast sensitivity, photostress recovery time after glare, de Boer scale, and Quality of Life Impact of Refractive Correction (QIRC) questionnaire results were evaluated. Multiple regression models were used to analyze the effect of the central hole location on parameters using the pupil center and visual axis as references based on Cartesian and polar coordinates. Results: The safety index was 1.13 and the efficacy index, 1.12. Under all testing circumstances, central hole decentration did not affect the visual acuity or contrast sensitivity. With the visual axis as a reference, worse QIRC values were associated with greater upward central hole displacement (P = .03) and a lower polar angle value (P = .008); also, halogen glare discomfort was greater with a higher radius (P = .04). Using the pupil center as a reference, greater nasal central hole decentration was associated with longer xenon glare photostress recovery time (P = .002). Conclusions: Implantation of the ICL with a central hole yielded excellent visual outcomes, even under increasing glare sources, regardless of the hole's location. However, hole decentration might affect patient-perceived quality of life, bothersome halogen glare, and longer xenon glare photostress recovery time. Such complaints after the early postoperative period might be managed with discrete ICL centration if the central hole is decentered upward or nasally. (C) 2019 ASCRS and ESCRS
引用
收藏
页码:1591 / 1596
页数:6
相关论文
共 29 条
[1]   Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up [J].
Alfonso, Jose F. ;
Baamonde, Begona ;
Fernandez-Vega, Luis ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) :873-880
[2]   Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Palacios, Ana ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :978-983
[3]  
Bullough J, 2002, SAE TECHNICAL PAPER
[4]   Dependability of Posterior-Segment Spectral Domain Optical Coherence Tomography for Measuring Central Corneal Thickness [J].
Correa-Perez, Maria E. ;
Olmo, Natalia ;
Lopez-Miguel, Alberto ;
Fernandez, Itziar ;
Coco-Martin, Mara B. ;
Maldonado, Miguel J. .
CORNEA, 2014, 33 (11) :1219-1224
[5]  
deBoer J.B., 1967, T ILLUMINATING ENG S, V32, P117, DOI [10.1177/147715356703200205, DOI 10.1177/147715356703200205]
[6]   Ring-shaped dysphotopsia associated with posterior chamber phakic implantable collamer lenses with a central hole [J].
Eom, Youngsub ;
Kim, Dae Wook ;
Ryu, Dongok ;
Kim, Jun-Heon ;
Yang, Seul Ki ;
Song, Jong Suk ;
Kim, Sug-Whan ;
Kim, Hyo Myung .
ACTA OPHTHALMOLOGICA, 2017, 95 (03) :E170-E178
[7]   Ghost-image analysis in phakic intraocular lenses with central hole as a potential cause of dysphotopsia [J].
Eppig, Timo ;
Spira, Corinna ;
Tsintarakis, Themistoklis ;
El-Husseiny, Moatasem ;
Cayless, Alan ;
Mueller, Marc ;
Seitz, Berthold ;
Langenbucher, Achim .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (11) :2552-2559
[8]   Intra-eye Visual Function Comparison With and Without a Central Hole Contact Lens-Based System: Potential Applications to ICL Design [J].
Ferrer-Blasco, Teresa ;
Garcia-Lazaro, Santiago ;
Belda-Salmeron, Lurdes ;
Albarran-Diego, Cesar ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (10) :702-707
[9]   The nature of foveal dark adaptation. [J].
Hecht, S .
JOURNAL OF GENERAL PHYSIOLOGY, 1921, 4 (02) :113-139
[10]   Intraocular Pressure after Implantation of the Visian Implantable Col lamer Lens With CentraFLOW Without Iridotomy [J].
Higueras-Esteban, Alejandro ;
Ortiz-Gomariz, Amanda ;
Gutierrez-Ortega, Ramon ;
Villa-Collar, Cesar ;
Abad-Montes, Juan P. ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (04) :800-805