Semi-Automated Hydrophobic Interaction Chromatography Column Scouting Used in the Two-Step Purification of Recombinant Green Fluorescent Protein

被引:5
|
作者
Stone, Orrin J.
Biette, Kelly M.
Murphy, Patrick J. M. [1 ]
机构
[1] Seattle Univ, Interdisciplinary Hlth Sci Res Lab, Coll Nursing, Seattle, WA 98122 USA
来源
PLOS ONE | 2014年 / 9卷 / 09期
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
NITRIC-OXIDE SYNTHASE; GFP FUSION PROTEINS; RAPID PURIFICATION; MOLECULAR-BIOLOGY; ESCHERICHIA-COLI; EXPRESSION; STUDENTS; PURITY; YIELD;
D O I
10.1371/journal.pone.0108611
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Methods and Results: Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A(395)) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 mu m matrix produced the highest degree of target protein capture and separation. Conclusions: Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in development other of HIC-compatible protein purification schemes.
引用
收藏
页数:9
相关论文
共 48 条
  • [1] Development of a robust and semi-automated two-step antibody purification process
    Yang, Xiaomin
    Yuan, Richard
    Garcia, Christopher
    Berry, Jessica
    Foster, Denisa
    He, Dongmei
    Zhang, Gui-Feng
    Jones, Bryan E.
    MABS, 2021, 13 (01)
  • [2] PURIFICATION OF RECOMBINANT GREEN FLUORESCENT PROTEIN FROM ESCHERICHIA COLI USING HYDROPHOBIC INTERACTION CHROMATOGRAPHY
    Noor, Siti Sarah Mohd.
    Tey, Beng Ti
    Tan, Wen Siang
    Ling, Tau Chuan
    Ramanan, Ramakrishnan Nagasundara
    Ooi, Chien Wei
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (13) : 1873 - 1884
  • [3] Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
    Murphy, Patrick J. M.
    Stone, Orrin J.
    Anderson, Michelle E.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (55):
  • [4] Refolding and two-step purification by hydrophobic interaction chromatography of recombinant human bone morphogenetic protein-2 from Escherichia coli
    Guo, Wangming
    Zhu, Xiangcheng
    Cai, Jin
    Huang, Lei
    Cen, Peilin
    Xu, Zhinan
    PROCESS BIOCHEMISTRY, 2012, 47 (06) : 960 - 967
  • [5] Evaluation of recombinant green fluorescent protein, under various culture conditions and purification with HiTrap hydrophobic interaction chromatography resins
    Penna, TCV
    Ishii, M
    Pessoa, A
    De Oliveira, L
    De Souza, LC
    Cholewa, O
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2004, 113 : 453 - 468
  • [6] Evaluation of recombinant green fluorescent protein, under various culture conditions and purification with HiTrap hydrophobic interaction chromatography resins
    Thereza Christina Vessoni Penna
    Marina Ishii
    Adalberto Pessoa Junior
    Laura de Oliveira Nascimento
    Luciana Cambricoli de Souza
    Olivia Cholewa
    Applied Biochemistry and Biotechnology, 2004, 114 (1-3) : 453 - 468
  • [7] Purification of the recombinant green fluorescent protein from tobacco plants using alcohol/salt aqueous two-phase system and hydrophobic interaction chromatography
    Jie Dong
    Xiangzhen Ding
    Sheng Wang
    BMC Biotechnology, 19
  • [8] Purification of the recombinant green fluorescent protein from tobacco plants using alcohol/salt aqueous two-phase system and hydrophobic interaction chromatography
    Dong, Jie
    Ding, Xiangzhen
    Wang, Sheng
    BMC BIOTECHNOLOGY, 2019, 19 (01)
  • [9] RAPID PURIFICATION OF RECOMBINANT GREEN FLUORESCENT PROTEIN USING THE HYDROPHOBIC PROPERTIES OF AN HPLC SIZE-EXCLUSION COLUMN
    DESCHAMPS, JR
    MILLER, CE
    WARD, KB
    PROTEIN EXPRESSION AND PURIFICATION, 1995, 6 (04) : 555 - 558
  • [10] A Rapid, Scalable, Two-Step Column Chromatography Purification of rAAV Vectors
    Wang, Lijun
    Veres, Gabor
    Knop, David R.
    MOLECULAR THERAPY, 2009, 17 : S273 - S273