Pitch Matching in Cochlear Implant Users With Single-Sided Deafness: Effects of Electrode Position and Acoustic Stimulus Type

被引:18
作者
Adel, Youssef [1 ,3 ]
Nagel, Sharon [1 ]
Weissgerber, Tobias [1 ]
Baumann, Uwe [1 ]
Macherey, Olivier [2 ]
机构
[1] Univ Hosp Frankfurt, Dept Otorhinolaryngol, Audiol Acoust, Frankfurt, Germany
[2] Aix Marseille Univ, LMA, Cent Marseille, CNRS, Marseille, France
[3] Univ Tubingen, Med Ctr, Tubingen Heating Res Ctr, Dept Otorhinolaryngol Head & Neck Surg, Tubingen, Germany
关键词
cochlear implant; pitch perception; single-sided deafness; simulation; pulse-spreading harmonic complex; binary search procedure; non-sensory bias; ELECTRICAL-STIMULATION; SPIRAL GANGLION; PLACE PITCH; FREQUENCY; PERCEPTION; COMPLEX; HEARING; INSERTION; MAP;
D O I
10.3389/fnins.2019.01119
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Previous studies in patients with single-sided deafness (SSD) have reported results of pitch comparisons between electric stimulation of their cochlear implant (CI) and acoustic stimulation presented to their near-normal hearing contralateral ear. These comparisons typically used sinusoids, although the percept elicited by electric stimulation may be closer to a wideband stimulus. Furthermore, it has been shown that pitch comparisons between sounds with different timbres is a difficult task and subjected to various types of range biases. The present study aims to introduce a method to minimize non-sensory biases, and to investigate the effect of different acoustic stimulus types on the frequency and variability of the electric-acoustic pitch matches. Pitch matches were collected from 13 CI users with SSD using the binary search procedure. Electric stimulation was presented at either an apical or a middle electrode position, at a rate of 800 pps. Acoustic stimulus types were sinusoids (SINE), 1/3-octave wide narrow bands of Gaussian noises (NBN), or 1/3-octave wide pulse spreading harmonic complexes (PSHC). On the one hand, NBN and PSHC are presumed to better mimic the spread of excitation produced by a single-electrode stimulation than SINE. On the other hand, SINE and PSHC contain less inherent fluctuations than NBN and may therefore provide a temporal pattern closer to that produced by a constant-amplitude electric pulse train. Analysis of mean pitch match variance showed no differences between stimulus types. However, mean pitch matches showed effects of electrode position and stimulus type, with the middle electrode always matched to a higher frequency than the apical one (p < 0.001), and significantly higher across-subject pitch matches for PSHC compared with SINE (p = 0.017). Mean pitch matches for all stimulus types were better predicted by place-dependent characteristic frequencies (CFs) based on an organ of Corti map compared with a spiral ganglion map. CF predictions were closest to pitch matches with SINE for the apical electrode position, and conversely with NBN or PSHC for the middle electrode position. These results provide evidence that the choice of acoustic stimulus type can have a significant effect on electric-acoustic pitch matching.
引用
收藏
页数:15
相关论文
共 47 条
[1]   The role of intensity upon pitch perception in cochlear implant recipients [J].
Arnoldner, Christoph ;
Kaider, Alexandra ;
Hamzavi, Jafar .
LARYNGOSCOPE, 2006, 116 (10) :1760-1765
[2]   Acoustic to electric pitch comparisons in cochlear implant subjects with residual hearing [J].
Boëx, Colette ;
Baud, Lionel ;
Cosendai, Grégoire ;
Sigrist, Alain ;
Kós, Maria-Izabel ;
Pelizzone, Marco .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2006, 7 (02) :110-124
[3]   Temporal Considerations for Stimulating Spiral Ganglion Neurons with Cochlear Implants [J].
Boulet, Jason ;
White, Mark ;
Bruce, Ian C. .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2016, 17 (01) :1-17
[4]   The psychophysics toolbox [J].
Brainard, DH .
SPATIAL VISION, 1997, 10 (04) :433-436
[5]   Pitch Comparisons between Electrical Stimulation of a Cochlear Implant and Acoustic Stimuli Presented to a Normal-hearing Contralateral Ear [J].
Carlyon, Robert P. ;
Macherey, Olivier ;
Frijns, Johan H. M. ;
Axon, Patrick R. ;
Kalkman, Randy K. ;
Boyle, Patrick ;
Baguley, David M. ;
Briggs, John ;
Deeks, John M. ;
Briaire, Jeroen J. ;
Barreau, Xavier ;
Dauman, Rene .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2010, 11 (04) :625-640
[6]   Further examination of complex pitch perception in the absence of a place-rate match [J].
Deeks, John M. ;
Gockel, Hedwig E. ;
Carlyon, Robert P. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (01) :377-388
[7]   An overview of cochlear implant electrode array designse [J].
Dhanasingh, Anandhan ;
Jolly, Claude .
HEARING RESEARCH, 2017, 356 :93-103
[8]   Implications of deep electrode insertion on cochlear implant fitting [J].
Gani, Mathieu ;
Valentini, Gregory ;
Sigrist, Alain ;
Kos, Maria-Izabel ;
Boex, Colette .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2007, 8 (01) :69-83
[9]   Interaural Pitch-Discrimination Range Effects for Bilateral and Single-Sided-Deafness Cochlear-Implant Users [J].
Goupell, Matthew J. ;
Cosentino, Stefano ;
Stakhovskaya, Olga A. ;
Bernstein, Joshua G. W. .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2019, 20 (02) :187-203
[10]   Frequency selectivity of contralateral residual acoustic hearing in bimodal cochlear implant users, and limitations on the ability to match the pitch of electric and acoustic stimuli [J].
Green, Tim ;
Faulkner, Andrew ;
Rosen, Stuart .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2012, 51 (05) :389-398