Detection of hepatic metastases: Ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography

被引:247
作者
Seneterre, E
Taourel, P
Bouvier, Y
Pradel, J
VanBeers, B
Daures, JP
Pringot, J
Mathieu, D
Bruel, JM
机构
[1] HOP ST LUC,DEPT RADIOL & MED IMAGING,BRUSSELS,BELGIUM
[2] HOP G DOUMERGUE,DEPT MED INFORMAT,F-30000 NIMES,FRANCE
[3] HOP HENRI MONDOR,DEPT MED IMAGING,F-94010 CRETEIL,FRANCE
关键词
computed tomography (CT); comparative studies; iron; liver neoplasms; CT; MR; magnetic resonance (MR); contrast enhancement; portography;
D O I
10.1148/radiology.200.3.8756932
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively compare the diagnostic accuracy of computed tomography (CT) during arterial portography (CTAP) with that of unenhanced and ferumoxides-enhanced magnetic resonance (MR) imaging at 0.5 T in the detection of hepatic metastases. MATERIALS AND METHODS: Four pairs of radiologists independently assessed the metastatic involvement of 134 hepatic segments (31 with and 103 without metastasis) in 17 patients at unenhanced and ferumoxides-enhanced spin-echo and gradient-echo MR imaging (alone and in combination) and at CTAP. The diagnostic performance of the various imaging modalities was assessed by means of receiver operating characteristic analysis. RESULTS: The accuracy of CTAP, unenhanced MR imaging (combined unenhanced sequences), and ferumoxides-enhanced MR imaging (combined contrast material-enhanced sequences) was 0.925, 0.908, and 0.951, respectively. Ferumoxides-enhanced MR imaging was significantly more accurate (P < .05) than unenhanced MR imaging and CTAP. When 14 segments containing cysts were excluded, the difference between ferumoxides-enhanced MR imaging and CTAP was no longer statistically significant (P = .1). CONCLUSION: Ferumoxides-enhanced MR imaging is more accurate than unenhanced MR imaging and at least as accurate as CTAP for the detection of hepatic metastases.
引用
收藏
页码:785 / 792
页数:8
相关论文
共 38 条
  • [1] ASSESSMENT OF RADIOLOGIC TESTS - CONTROL OF BIAS AND OTHER DESIGN CONSIDERATIONS
    BEGG, CB
    MCNEIL, BJ
    [J]. RADIOLOGY, 1988, 167 (02) : 565 - 569
  • [2] LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING
    BELLIN, MF
    ZAIM, S
    AUBERTON, E
    SARFATI, G
    DURON, JJ
    KHAYAT, D
    GRELLET, J
    [J]. RADIOLOGY, 1994, 193 (03) : 657 - 663
  • [3] BRUEL JM, 1993, RADIOLOGY, V189, P273
  • [4] DETECTION OF COLORECTAL LIVER METASTASES USING INTRAOPERATIVE ULTRASONOGRAPHY
    CHARNLEY, RM
    MORRIS, DL
    DENNISON, AR
    AMAR, SS
    HARDCASTLE, JD
    [J]. BRITISH JOURNAL OF SURGERY, 1991, 78 (01) : 45 - 48
  • [5] Couinaud C., 1957, FOIE ETUDES ANATOMIQ
  • [6] MR-IMAGING OF THE LIVER - BREATH-HOLD T1-WEIGHTED MP-GRE COMPARED WITH CONVENTIONAL T2-WEIGHTED SE IMAGING - LESION DETECTION, LOCALIZATION, AND CHARACTERIZATION
    DELANGE, EE
    MUGLER, JP
    BOSWORTH, JE
    DEANGELIS, GA
    GAY, SB
    HURT, NS
    BERR, SS
    ROSENBLATT, JM
    MERICKEL, LW
    HARRIS, EK
    [J]. RADIOLOGY, 1994, 190 (03) : 727 - 736
  • [7] DENYS A, 1994, RADIOLOGY, V193, P663
  • [8] AN AMERICANS GUIDE TO COUINAUD NUMBERING SYSTEM
    DODD, GD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (03) : 574 - 575
  • [9] DYNAMIC MR IMAGING OF THE LIVER WITH GD-DTPA - INITIAL CLINICAL-RESULTS
    EDELMAN, RR
    SIEGEL, JB
    SINGER, A
    DUPUIS, K
    LONGMAID, HE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) : 1213 - 1219
  • [10] SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER
    FRETZ, CJ
    ELIZONDO, G
    WEISSLEDER, R
    HAHN, PF
    STARK, DD
    FERRUCCI, JT
    [J]. RADIOLOGY, 1989, 172 (02) : 393 - 397