Determination of 5-fluorouracil in hospital effluents

被引:97
作者
Mahnik, SN
Rizovski, B
Fuerhacker, M
Mader, RM
机构
[1] Med Univ Vienna, Div Clin Oncol, Dept Med 1, A-1090 Vienna, Austria
[2] Univ Nat Resources & Appl Life Sci, BOKU, Inst Sanit Engn & Water Pollut Control, Dept Water Atmosphere Environm, A-1190 Vienna, Austria
关键词
5-fluorouracil; capillary electrophoresis; hospital effluents;
D O I
10.1007/s00216-004-2727-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cytostatic anticancer drugs are an increasingly important issue in the environmental debate, mainly due to the lack of knowledge about the fate of these toxic substances. Over the last decades, 5-fluorouracil (5-FU) has been one of the most frequently used antineoplastic agents and may, therefore, be regarded as one of the pilot substances for environmental contamination. As a prerequisite for these investigations, a method for the determination of 5-FU in hospital effluents has been developed. Waste water samples were enriched by solid-phase extraction on ENV+ columns (concentration factor 500) and analysed by capillary electrophoresis using a buffer containing 80% 160 mM sodium borate buffer (pH 9.5) and 20% acetonitrile (v/v). This method is applicable within the range 5-500 mug 5-FU L-1. The standard curve (correlation coefficient > 0.99) was linear with recovery rates from 80 to 96% and an accuracy from 9.0 to 20% (intra-assay standard deviation 0.7-8.9%; inter-assay standard deviation 2.2-9.5%). Based on the consumption of 5-FU in oncologic departments and the detection limit of 1.7 mug L-1, this method covers the range necessary to evaluate 5-FU in hospital effluents. The applicability of the method was proven by chemical analysis of real hospital waste water samples. Obtained over a time period of 1 month (range 20-122 mug 5-FU L-1), the results were similar to those calculated by an input-output model. The presented method provides an analytical tool necessary to face the monitoring of environmental contamination problems.
引用
收藏
页码:31 / 35
页数:5
相关论文
共 16 条
[1]   Determination of halogens in organic compounds by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) [J].
Bu, XD ;
Wang, TB ;
Hall, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (12) :1443-1451
[2]   Simultaneous HPLC determination of 5-fluorouracil and its metabolites in plasma of cancer patients [J].
Casale, F ;
Canaparo, R ;
Muntoni, E ;
Serpe, L ;
Zara, GP ;
Pepa, CD ;
Berno, E ;
Costa, M ;
Eandi, M .
BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (07) :446-452
[3]   Sensitive liquid chromatographic assay for the simultaneous determination of 5-fluorouracil and its prodrug, tegafur, in beagle dog plasma [J].
Chu, DF ;
Gu, JK ;
Liu, WH ;
Fawcett, JP ;
Dong, QG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (02) :377-382
[4]   A MATHEMATICAL-MODEL OF THE KINETICS OF 5-FLUOROURACIL AND ITS METABOLITES IN CANCER-PATIENTS [J].
COUSTERE, C ;
MENTRE, F ;
SOMMADOSSI, JP ;
DIASIO, RB ;
STEIMER, JL .
CANCER CHEMOTHERAPY AND PHARMACOLOGY, 1991, 28 (02) :123-129
[5]   CLINICAL-PHARMACOLOGY OF 5-FLUOROURACIL [J].
DIASIO, RB ;
HARRIS, BE .
CLINICAL PHARMACOKINETICS, 1989, 16 (04) :215-237
[6]  
DORR RT, 1994, CANC CHEMOTHERAPY BO
[7]  
HEGGIE GD, 1987, CANCER RES, V47, P2203
[8]   Trace enrichment, chromatographic separation and biodegradation of cytostatic compounds in surface water [J].
Kiffmeyer, T ;
Gotze, HJ ;
Jursch, M ;
Luders, U .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (02) :185-191
[9]  
KIFFMEYER TK, 1998, THESIS U BOCHUM
[10]   Biodegradability of the anti-tumour agents 5-fluorouracil, cytarabine, and gemcitabine:: Impact of the chemical structure and synergistic toxicity with hospital effluent [J].
Kümmerer, K ;
Al-Ahmad, A .
ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 1997, 25 (04) :166-172