Mechanical Strength and Rheological Properties of Tissue Adhesives With Regard to Colorectal Anastomosis An Ex Vivo Study

被引:76
|
作者
Vakalopoulos, Konstantinos Aristotelis [1 ]
Wu, Zhouqiao [1 ]
Kroese, Leonard [1 ]
Kleinrensink, Gert-Jan [2 ]
Jeekel, Johannes [2 ]
Vendamme, Richard [3 ]
Dodou, Dimitra [4 ]
Lange, Johan Frederik [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Surg, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Neurosci, NL-3000 CA Rotterdam, Netherlands
[3] Nitto Europe NV, European Res Comm, Genk, Belgium
[4] Delft Univ Technol, Delft, Netherlands
关键词
anastomotic leakage; colorectal surgery; surgical glue; tissue adhesives; SURGICAL ADHESIVE; SEALANTS; SURGERY; GLUE; BIOGLUE;
D O I
10.1097/SLA.0000000000000599
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare mechanical strength and rheology of existing tissue adhesives in a clinically relevant test setup with regard to colorectal anastomosis. Background: Little is known on the mechanical strength of tissue adhesives directly after application. Furthermore, rheological profiling may be important in understanding mechanical performance and explaining differences between adhesives. This study provides new data on the mechanical strength and rheology of a comprehensive list of tissue adhesives with regard to colorectal adhesiveness. Methods: Twelve surgical tissue adhesives were included: 4 cyanoacrylate adhesives (CA), 2 fibrin glues (FG), 3 polyethylene glycol (PEG) adhesives, and 3 albumin-based (AB) adhesives. Tubular rat colonic segments were glued together. Tensile (T), shear (S), and peel (P) strength were measured. Shear storage (G') and shear loss (G '') moduli were also evaluated. Results: CA adhesives were stronger than AB (T: P = 0.017; S: P = 0.064; P: P < 0.001), which, in turn, were stronger than PEG (T: P < 0.001; S: P < 0.001; P: P = 0.018). PEG were stronger than FG for shear (P = 0.013) and comparable for tensile and peel strength (P > 0.05). Within-group variation was smallest for CA. Mechanical strength correlated strongly between performed tests. Rheological properties (G' and G '') correlated strongly with mechanical strength for all adhesives combined. Conclusions: CA adhesives are the strongest and most homogenous group in terms of mechanical strength. Hydrogels (FG, AB) are heterogeneous, with lower mechanical strength than CA. FG are mechanically the weakest adhesives. Rheological profiles correlate to mechanical strength and may be useful for predicting mechanical performance.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 23 条
  • [21] Radiofrequency-induced small bowel thermofusion: an ex vivo study of intestinal seal adequacy using mechanical and imaging modalities
    Arya, Shobhit
    Hadjievangelou, Nancy
    Lei, Su
    Kudo, Hiromi
    Goldin, Robert D.
    Darzi, Ara W.
    Elson, Daniel S.
    Hanna, George B.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (09): : 3485 - 3496
  • [22] Histological and Thermometric Examination of Soft Tissue De-Epithelialization Using Digitally Controlled Er:YAG Laser Handpiece: An Ex Vivo Study
    Grzech-Lesniak, Kinga
    Matys, Jacek
    Jurczyszyn, Kamil
    Ziolkowski, Piotr
    Dominiak, Marzena
    Brugnera, Aldo, Jr.
    Romeo, Umberto
    PHOTOMEDICINE AND LASER SURGERY, 2018, 36 (06) : 313 - 319
  • [23] Pre-Operative Mechanical Bowel Preparation Does Not Affect the Impact of Anastomosis Leakage in Left-Side Colorectal Surgery-A Single Center Observational Study
    Danihel, Ludovit
    Cerny, Marian
    Dropco, Ivor
    Zrnikova, Petra
    Schnorrer, Milan
    Smolar, Marek
    Misanik, Miloslav
    Durdik, Stefan
    LIFE-BASEL, 2024, 14 (09):