Mechanical Strength and Rheological Properties of Tissue Adhesives With Regard to Colorectal Anastomosis An Ex Vivo Study

被引:76
|
作者
Vakalopoulos, Konstantinos Aristotelis [1 ]
Wu, Zhouqiao [1 ]
Kroese, Leonard [1 ]
Kleinrensink, Gert-Jan [2 ]
Jeekel, Johannes [2 ]
Vendamme, Richard [3 ]
Dodou, Dimitra [4 ]
Lange, Johan Frederik [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Surg, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Neurosci, NL-3000 CA Rotterdam, Netherlands
[3] Nitto Europe NV, European Res Comm, Genk, Belgium
[4] Delft Univ Technol, Delft, Netherlands
关键词
anastomotic leakage; colorectal surgery; surgical glue; tissue adhesives; SURGICAL ADHESIVE; SEALANTS; SURGERY; GLUE; BIOGLUE;
D O I
10.1097/SLA.0000000000000599
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare mechanical strength and rheology of existing tissue adhesives in a clinically relevant test setup with regard to colorectal anastomosis. Background: Little is known on the mechanical strength of tissue adhesives directly after application. Furthermore, rheological profiling may be important in understanding mechanical performance and explaining differences between adhesives. This study provides new data on the mechanical strength and rheology of a comprehensive list of tissue adhesives with regard to colorectal adhesiveness. Methods: Twelve surgical tissue adhesives were included: 4 cyanoacrylate adhesives (CA), 2 fibrin glues (FG), 3 polyethylene glycol (PEG) adhesives, and 3 albumin-based (AB) adhesives. Tubular rat colonic segments were glued together. Tensile (T), shear (S), and peel (P) strength were measured. Shear storage (G') and shear loss (G '') moduli were also evaluated. Results: CA adhesives were stronger than AB (T: P = 0.017; S: P = 0.064; P: P < 0.001), which, in turn, were stronger than PEG (T: P < 0.001; S: P < 0.001; P: P = 0.018). PEG were stronger than FG for shear (P = 0.013) and comparable for tensile and peel strength (P > 0.05). Within-group variation was smallest for CA. Mechanical strength correlated strongly between performed tests. Rheological properties (G' and G '') correlated strongly with mechanical strength for all adhesives combined. Conclusions: CA adhesives are the strongest and most homogenous group in terms of mechanical strength. Hydrogels (FG, AB) are heterogeneous, with lower mechanical strength than CA. FG are mechanically the weakest adhesives. Rheological profiles correlate to mechanical strength and may be useful for predicting mechanical performance.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 23 条
  • [11] Detecting colorectal cancer using electrical impedance spectroscopy: an ex vivo feasibility study
    Pathiraja, Angela
    Ziprin, Paul
    Shiraz, Arsam
    Mirnezami, Reza
    Tizzard, Andrew
    Brown, Brian
    Demosthenous, Andreas
    Bayford, Richard
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (06) : 1278 - 1288
  • [12] Temporary percutaneous ileostomy versus conventional loop ileostomy in mechanical extraperitoneal colorectal anastomosis: A retrospective study
    Rondelli, F.
    Balzarotti, R.
    Bugiantella, W.
    Mariani, L.
    Pugliese, R.
    Mariani, E.
    EJSO, 2012, 38 (11): : 1065 - 1070
  • [13] Radiation absorption in different kinds of tissue analysis: ex vivo study with supercontinuum laser source
    Fornaini, Carlo
    Merigo, Elisabetta
    Selleri, Stefano
    Cucinotta, Annamaria
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXVII, 2016, 9706
  • [14] Effects on Bone Tissue After Osteotomy with Different High-Energy Lasers: An Ex Vivo Study
    Pimentel Lopes de Oliveira, Guilherme Jose
    Campelo Rodrigues, Conrado Nogueira
    Perussi, Livia Rodrigues
    de Souza Rastelli, Alessandra Nara
    Chierici Marcantonio, Rosemary Adriana
    Camargo Villela Berbert, Fabio Luiz
    PHOTOMEDICINE AND LASER SURGERY, 2016, 34 (07) : 291 - 296
  • [15] Compatibility of temporary pacemaker myocardial pacing leads with magnetic resonance imaging: an ex vivo tissue study
    Pfeil, Alexander
    Drobnik, Stefanie
    Rzanny, Reinhard
    Aboud, Anas
    Boettcher, Joachim
    Schmidt, Peter
    Ortmann, Christian
    Mall, Gita
    Hekmat, Khosro
    Brehm, Bernhard
    Reichenbach, Juergen
    Mayer, Thomas E.
    Wolf, Gunter
    Hansch, Andreas
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (02) : 317 - 326
  • [16] Photothermal ablation of liver tissue with 1940-nm thulium fiber laser: an ex vivo study on lamb liver
    Alagha, Heba Z.
    Gulsoy, Murat
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (01)
  • [17] Combined center of rotation of angulation-based leveling osteotomy and tibial tuberosity transposition: An ex vivo mechanical study
    Clough, W. Tyler
    Dycus, David L.
    Barnhart, Matthew D.
    Hulse, Don A.
    Litsky, Alan S.
    VETERINARY SURGERY, 2022, 51 (03) : 489 - 496
  • [18] In vivo characterization of mechanical tissue properties of internal organs using endoscopic microscopy and inverse finite element analysis
    Schwenninger, David
    Schumann, Stefan
    Guttmann, Josef
    JOURNAL OF BIOMECHANICS, 2011, 44 (03) : 487 - 493
  • [19] Digital image correlation and finite element modelling as a method to determine mechanical properties of human soft tissue in vivo
    Moerman, Kevin M.
    Holt, Cathy A.
    Evans, Sam L.
    Simms, Ciaran K.
    JOURNAL OF BIOMECHANICS, 2009, 42 (08) : 1150 - 1153
  • [20] Imaging high-intensity focused ultrasound-induced tissue denaturation by multispectral photoacoustic method: an ex vivo study
    Sun, Yao
    O'Neill, Brian
    APPLIED OPTICS, 2013, 52 (08) : 1764 - 1770