Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry

被引:112
|
作者
Kunert, Kathleen S. [1 ]
Peter, Monika [2 ]
Blum, Marcus [1 ]
Haigis, Wolfgang [3 ]
Sekundo, Walter [4 ]
Schuetze, Juliane [5 ]
Bueehren, Tobias [2 ]
机构
[1] Helios Hosp Erfurt, Dept Ophthalmol, Nordhaeuserstr 74, D-99089 Erfurt, Germany
[2] Carl Zeiss Meditec AG, Jena, Germany
[3] Univ Wurzburg, Univ Eye Clin & Polyclin, D-97070 Wurzburg, Germany
[4] Univ Marburg, Dept Ophthalmol, Marburg, Germany
[5] Univ Appl Sci, Jena, Germany
关键词
CENTRAL CORNEAL THICKNESS; LENS POWER CALCULATION; KERATOMETRY; REPRODUCIBILITY; DEVICE; PRECISION;
D O I
10.1016/j.jcrs.2015.07.039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). SETTING: Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Wurzburg, and Philipps University, Marburg, Germany. DESIGN: Prospective comparative multicenter clinical study. METHODS: Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. RESULTS: One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 mu m +/- 25 (SD), 17 +/- 122 mu m, and -0.001 +/- 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 +/- 122 mu m and 0.15 +/- 4.51 mu m, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 mu m, 9.8 mu m, 2.3 mu m, 19.5 mu m, and 0.1 D, respectively. CONCLUSIONS: Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [31] Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
    Daiki Sakai
    Satoshi Yokota
    Akiko Maeda
    Yasuhiko Hirami
    Makoto Nakamura
    Yasuo Kurimoto
    BMC Ophthalmology, 22
  • [32] Comparison of a new Scheimpflug imaging combined with partial coherence interferometry biometer and a low-coherence reflectometry biometer
    Ruiz-Mesa, Ramon
    Abengozar-Vela, Antonio
    Ruiz-Santos, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (11) : 1406 - 1412
  • [33] Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
    Sakai, Daiki
    Yokota, Satoshi
    Maeda, Akiko
    Hirami, Yasuhiko
    Nakamura, Makoto
    Kurimoto, Yasuo
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [34] Biometry measurements using a new large-coherence-length swept-source optical coherence tomographer
    Shammas, H. John
    Ortiz, Sergio
    Shammas, Maya C.
    Kim, Seong Hwan
    Chong, Changho
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01) : 50 - 61
  • [35] Accuracy and Repeatability of an Anterior Segment Swept-Source Optical Coherence Tomographer
    Peguda, Rajini
    Kang, Pauline
    Maseedupally, Vinod
    Swarbrick, Helen
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S300 - S306
  • [36] Comparative analysis of two optical biometry devices: high wavelength swept source OCT versus partial coherence interferometry
    Szalai, Eszter
    Csutak, Adrienne
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (02) : 627 - 634
  • [37] Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
    Huang, Jinhai
    Zhao, Yuyu
    Savini, Giacomo
    Yu, Guanshun
    Yu, Jinjin
    Chen, Zhongxing
    Tu, Ruixue
    Zhao, Yune
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [38] Comparison of anterior ocular biometry between optical low-coherence reflectometry and anterior segment optical coherence tomography in an adult Chinese population
    Shen, Peiyang
    Ding, Xiaohu
    Congdon, Nathan G.
    Zheng, Yingfeng
    He, Mingguang
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06) : 966 - 970
  • [39] Lower Tear Meniscus Measurements Using a New Anterior Segment Swept-Source Optical Coherence Tomography and Agreement With Fourier-Domain Optical Coherence Tomography
    Arriola-Villalobos, Pedro
    Ignacio Fernandez-Vigo, Jose
    Diaz-Valle, David
    Almendral-Gomez, Jaime
    Fernandez-Perez, Cristina
    Benitez-del-Castillo, Jose M.
    CORNEA, 2017, 36 (02) : 183 - 188
  • [40] Accuracy of a New Swept-Source Optical Coherence Tomography Biometer for IOL Power Calculation and Comparison to IOL Master
    Savini, Giacomo
    Hoffer, Kenneth J.
    Shammas, H. John
    Aramberri, Jaime
    Huang, Jinhai
    Barboni, Piero
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (10) : 690 - 695