Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry

被引:112
|
作者
Kunert, Kathleen S. [1 ]
Peter, Monika [2 ]
Blum, Marcus [1 ]
Haigis, Wolfgang [3 ]
Sekundo, Walter [4 ]
Schuetze, Juliane [5 ]
Bueehren, Tobias [2 ]
机构
[1] Helios Hosp Erfurt, Dept Ophthalmol, Nordhaeuserstr 74, D-99089 Erfurt, Germany
[2] Carl Zeiss Meditec AG, Jena, Germany
[3] Univ Wurzburg, Univ Eye Clin & Polyclin, D-97070 Wurzburg, Germany
[4] Univ Marburg, Dept Ophthalmol, Marburg, Germany
[5] Univ Appl Sci, Jena, Germany
关键词
CENTRAL CORNEAL THICKNESS; LENS POWER CALCULATION; KERATOMETRY; REPRODUCIBILITY; DEVICE; PRECISION;
D O I
10.1016/j.jcrs.2015.07.039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). SETTING: Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Wurzburg, and Philipps University, Marburg, Germany. DESIGN: Prospective comparative multicenter clinical study. METHODS: Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. RESULTS: One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 mu m +/- 25 (SD), 17 +/- 122 mu m, and -0.001 +/- 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 +/- 122 mu m and 0.15 +/- 4.51 mu m, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 mu m, 9.8 mu m, 2.3 mu m, 19.5 mu m, and 0.1 D, respectively. CONCLUSIONS: Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [1] Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer
    Arriola-Villalobos, P.
    Almendral-Gomez, J.
    Garzon, N.
    Ruiz-Medrano, J.
    Fernandez-Perez, C.
    Martinez-de-la-Casa, J. M.
    Diaz-Valle, D.
    EYE, 2017, 31 (03) : 437 - 442
  • [2] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Dominguez-Vicent, Alberto
    Venkataraman, Abinaya Priya
    Dalin, Amanda
    Brautaset, Rune
    Montes-Mico, Robert
    EYE AND VISION, 2023, 10 (01)
  • [3] Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry
    Hoffer, Kenneth J.
    Hoffmann, Peter C.
    Savini, Giacomo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) : 1165 - 1172
  • [4] Repeatability and reproducibility of a new spectral-domain optical coherence tomography biometer and agreement with swept-source optical coherence tomography based biometer
    Li, Xin
    Lei, Chak Seng
    Ning, Rui
    Liu, Luze
    Chen, Aodong
    Yang, Xinning
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    EYE AND VISION, 2025, 12 (01)
  • [5] Repeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes
    Ardoy, Elisa Garcia
    Mateos, Nuria
    Roda, Laura
    Sierra, Oscar Torrado
    Baptista, Antonio M.
    Serra, Pedro M.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2023, 106 (07) : 783 - 792
  • [6] Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer
    Fisus, Andreea D.
    Hirnschall, Nino D.
    Ruiss, Manuel
    Pilwachs, Caroline
    Georgiev, Stefan
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (10) : 1302 - 1307
  • [7] Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
    Srivannaboon, Sabong
    Chirapapaisan, Chareenun
    Chonpimai, Pratuangsri
    Loket, Siriwan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10) : 2224 - 2232
  • [8] Ocular measurements of a swept-source biometer: Repeatability data and comparison with an optical low-coherence interferometry biometer
    Nemeth, Gabor
    Modis, Laszlo, Jr.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06) : 789 - 797
  • [9] Measurement agreement between a new biometer based on partial coherence interferometry and a validated biometer based on optical low-coherence reflectometry
    Li, Junhua
    Chen, Hao
    Savini, Giacomo
    Lu, Weicong
    Yu, Xinxin
    Bao, Fangjun
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01) : 68 - 75
  • [10] Comparison of a New Optical Biometer That Combines Scheimpflug Imaging With Partial Coherence Interferometry With That of an Optical Biometer Based on Swept-Source Optical Coherence Tomography and Placido-Disk Topography
    Chen, Shihao
    Zhang, Qiaoyue
    Savini, Giacomo
    Zhang, Shuangzhe
    Huang, Xiaomin
    Yu, Jinjin
    Wang, Yirang
    Ning, Rui
    Huang, Jinhai
    Tu, Ruixue
    FRONTIERS IN MEDICINE, 2022, 8