A new real-time personal dosimeter with position monitoring based on a scintillator

被引:0
|
作者
Moon, Sun Young [1 ]
Yoon, Myonggeun [1 ]
Kim, Sun-Young [2 ]
Shin, Dongho [2 ]
机构
[1] Korea Univ, Dept Bioconvergence Engn, Seoul, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang, South Korea
基金
新加坡国家研究基金会;
关键词
Personal dosimeter; Scintillator; Occupational dosimetry; Real-time dosimeter;
D O I
10.1007/s40042-021-00075-5
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Personal dosimeters are used to measure the amount of radiation exposure in individual radiation workers. We aimed to replace existing personal dosimeters and evaluate a real-time scintillator-based dosimeter by monitoring its radiation dose and checking the location exposed to radiation in the workspace. The developed dosimeter measured the radiation dose based on a scintillating fiber (SF) bundle, and comprised a silicon photomultiplier (SiPM), ultra-wide-band (UWB)-based location detecting system, and Bluetooth system. The SF bundle was exposed to radiation-emitted light, and the photons were amplified and converted to electrical signals through the SiPM. These signals were transferred to the user through the Bluetooth system and monitored. To evaluate the feasibility of this mechanism as a dosimeter, we performed characteristic tests, such as dose linearity, dependence on dose rate, energy, exposed angle, and location coordinate mapping. Also, the dose distribution formed in circles around the iso-center was measured to confirm the feasibility of monitoring the exposure dose and location and to enable the radiation worker to move freely in a workspace. We confirmed dose linearity, independence from energy and angle, and accuracy of location monitoring in our device. The user's locations were measured with a difference of - 6 cm and - 4.8 cm on the x- and the y-axes, respectively. The measured doses on our developed dosimeter were 62.7, 32.3, 21.0, and 15.4 mSv at distances of 50, 100, 150, and 200 cm from the iso-center. In other words, all measured doses at several points showed an error within 5% as compared to doses provided by the conventional pocket dosimeter. These results show that the developed SF-based dosimeter is advantageous in monitoring the exposure dose and location in real time, and has significant potential as a new personal dosimeter for radiation workers.
引用
收藏
页码:1133 / 1140
页数:8
相关论文
共 50 条
  • [31] REAL-TIME MONITORING
    BLACKBUM, JP
    INTENSIVE CARE MEDICINE, 1979, 5 (03) : 158 - 158
  • [32] REAL-TIME MONITORING
    Thayer, Ann M.
    CHEMICAL & ENGINEERING NEWS, 2014, 92 (47) : 8 - 12
  • [33] The design of a real-time accelerometer-based baby sleeping position monitoring and correction system
    Sudharsanan, S.
    Karthikeyan, B.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2013, 12 (02) : 189 - 198
  • [34] Validation of a gyroscope-based wearable device for real-time position monitoring of patients in a hospital
    Lee, Jung Hwan
    Lee, Jae Il
    Kim, Dong Hwan
    Nam, Kyoung Hyup
    Jeon, Tae Jin
    Han, In Ho
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (04) : 843 - 848
  • [35] A real-time applicator position monitoring system for gynecologic intracavitary brachytherapy
    Xia, Junyi
    Waldron, Timothy
    Kim, Yusung
    MEDICAL PHYSICS, 2014, 41 (01)
  • [36] Development of a Real-Time Gamma Dosimeter of High Sensitivity
    Sharma, S. L.
    Maity, T. K.
    Kumar, G. Anil
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 341 - +
  • [37] Optical fiber dosimeter for real-time in-vivo dose monitoring during LDR brachytherapy
    Woulfe, P.
    Sullivan, F. J.
    Kam, W.
    O'Keeffe, S.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (07) : 4027 - 4036
  • [38] Development of a Micro-Sized Dosimeter for Real-Time Dose Monitoring and Small Field Dosimetry
    Volotskova, O.
    Jenkins, C.
    Fahimian, B.
    Xing, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3649 - 3650
  • [39] Characterization of Phosphorescent Strontium Aluminate as a Real-Time Dosimeter
    Drehmel, S.
    Mathew, D.
    Ehler, E.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] A new wireless MEMS-based system for real-time deformation monitoring
    Rensselaer Polytechnic Institute, 110 8th Street, JEC 4049, Troy, NY 12180
    Geotech News, 2008, 1 (36-40):