A new real-time personal dosimeter with position monitoring based on a scintillator

被引:0
|
作者
Moon, Sun Young [1 ]
Yoon, Myonggeun [1 ]
Kim, Sun-Young [2 ]
Shin, Dongho [2 ]
机构
[1] Korea Univ, Dept Bioconvergence Engn, Seoul, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang, South Korea
基金
新加坡国家研究基金会;
关键词
Personal dosimeter; Scintillator; Occupational dosimetry; Real-time dosimeter;
D O I
10.1007/s40042-021-00075-5
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Personal dosimeters are used to measure the amount of radiation exposure in individual radiation workers. We aimed to replace existing personal dosimeters and evaluate a real-time scintillator-based dosimeter by monitoring its radiation dose and checking the location exposed to radiation in the workspace. The developed dosimeter measured the radiation dose based on a scintillating fiber (SF) bundle, and comprised a silicon photomultiplier (SiPM), ultra-wide-band (UWB)-based location detecting system, and Bluetooth system. The SF bundle was exposed to radiation-emitted light, and the photons were amplified and converted to electrical signals through the SiPM. These signals were transferred to the user through the Bluetooth system and monitored. To evaluate the feasibility of this mechanism as a dosimeter, we performed characteristic tests, such as dose linearity, dependence on dose rate, energy, exposed angle, and location coordinate mapping. Also, the dose distribution formed in circles around the iso-center was measured to confirm the feasibility of monitoring the exposure dose and location and to enable the radiation worker to move freely in a workspace. We confirmed dose linearity, independence from energy and angle, and accuracy of location monitoring in our device. The user's locations were measured with a difference of - 6 cm and - 4.8 cm on the x- and the y-axes, respectively. The measured doses on our developed dosimeter were 62.7, 32.3, 21.0, and 15.4 mSv at distances of 50, 100, 150, and 200 cm from the iso-center. In other words, all measured doses at several points showed an error within 5% as compared to doses provided by the conventional pocket dosimeter. These results show that the developed SF-based dosimeter is advantageous in monitoring the exposure dose and location in real time, and has significant potential as a new personal dosimeter for radiation workers.
引用
收藏
页码:1133 / 1140
页数:8
相关论文
共 10 条
  • [1] A new real-time personal dosimeter with position monitoring based on a scintillator
    Sun Young Moon
    Myonggeun Yoon
    Sun-Young Kim
    Dongho Shin
    Journal of the Korean Physical Society, 2021, 78 : 1133 - 1140
  • [2] New real-time patient radiation dosimeter for use in radiofrequency catheter ablation
    Kato, Mamoru
    Chida, Koichi
    Nakamura, Masaaki
    Toyoshima, Hideto
    Terata, Ken
    Abe, Yoshihisa
    JOURNAL OF RADIATION RESEARCH, 2019, 60 (02) : 215 - 220
  • [3] Study of Wireless Sensor Network Application for Dosimeter Personal Real Time
    Fardela, Ramacos
    Kusminarto
    Ashari, Ahmad
    2018 INTERNATIONAL CONFERENCE ON ORANGE TECHNOLOGIES (ICOT), 2018,
  • [4] DEVELOPMENT OF PERSONAL DOSIMETER BASED ON NEW MEASUREMENT METHOD
    Wang Min
    Fang Fang
    Duan Xiaojuan
    Zhao Xiang
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 3, 2011, : 229 - +
  • [5] A SiPM based real time dosimeter for radiotherapic beams
    Berra, A.
    Conti, V.
    Lietti, D.
    Milan, L.
    Novati, C.
    Ostinelli, A.
    Prest, M.
    Romano, C.
    Vallazza, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 773 : 72 - 80
  • [6] Measurement of bow tie profiles in CT scanners using a real-time dosimeter
    Whiting, Bruce R.
    Evans, Joshua D.
    Dohatcu, Andreea C.
    Williamson, Jeffrey F.
    Politte, David G.
    MEDICAL PHYSICS, 2014, 41 (10)
  • [7] Characterization of Yb-doped silica optical fiber as real-time dosimeter
    Veronese, Ivan
    Chiodini, Norberto
    Cialdi, Simone
    D'Ippolito, Eduardo
    Fasoli, Mauro
    Gallo, Salvatore
    Mones, Eleonora
    Vedda, Anna
    Loi, Gianfranco
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIX, 2017, 10392
  • [8] New technologies for beam spectrometry, quality assurance, real-time monitoring and microdosimetry in BNCT
    Kumada, Hiroaki
    Masuda, Akihiko
    Tanaka, Hiroki
    Takada, Masashi
    Hu, Naonori
    RADIATION MEASUREMENTS, 2024, 177
  • [9] Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy
    Bruza, Petr
    Gollub, Sarah L.
    Andreozzi, Jacqueline M.
    Tendler, Irwin I.
    Williams, Benjamin B.
    Jarvis, Lesley A.
    Gladstone, David J.
    Pogue, Brian W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (09)
  • [10] Development of a real-time dose monitor with Cr-doped Gd3Ga5O12 infrared scintillator
    Kurosawa, Shunsuke
    Yamaji, Akihiro
    Kochurikhin, Vladimir V.
    Ivanov, Mikhail
    Pejchal, Jan
    Murakami, Rikito
    Shoji, Yasuhiro
    Ohashi, Yuji
    Yokota, Yuui
    Kamada, Kei
    Yoshikawa, Akira
    RADIATION MEASUREMENTS, 2017, 106 : 187 - 191