共 85 条
Highly sensitive and selective amperometric hydrazine sensor based on Au nanoparticle-decorated conducting polythiophene prepared via oxidative polymerization and photo-reduction techniques
被引:25
作者:
Rashed, Md. A.
[1
]
Faisal, M.
[1
]
Ahmed, Jahir
[1
]
Alsareii, S. A.
[1
,2
]
Jalalah, Mohammed
[1
,3
]
Harraz, Farid A.
[1
,4
]
机构:
[1] Najran Univ, Promising Ctr Sensors & Elect Devices PCSED, Adv Mat & Nanores Ctr, POB 1988, Najran 11001, Saudi Arabia
[2] Najran Univ, Coll Med, Dept Surg, Najran, Saudi Arabia
[3] Najran Univ, Fac Engn, Dept Elect Engn, Najran, Saudi Arabia
[4] Najran Univ, Fac Sci & Arts Sharurah, Dept Chem, Najran, Saudi Arabia
关键词:
AuNPs;
Polythiophene;
Hydrazine sensor;
Amperometry;
Selectivity;
GLASSY-CARBON ELECTRODE;
DOPED POROUS CARBON;
GOLD NANOPARTICLES;
ELECTROCATALYTIC OXIDATION;
PALLADIUM NANOPARTICLES;
MASS-SPECTROMETRY;
SPECTROPHOTOMETRIC DETERMINATION;
ELECTROCHEMICAL OXIDATION;
HYDROGEN-PEROXIDE;
TRACE AMOUNTS;
D O I:
10.1016/j.jscs.2022.101480
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
In this study, gold nanoparticles (AuNPs) decorated polythiophene (Pth) nanocomposite modified glassy carbon electrode (GCE) has been used to fabricate an electrochemical sensor for the sensitive and selective detection of hydrazine. Transmission electron microscope (TEM), Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD) were used to adequately characterize the nanocomposite. The research findings revealed that AuNPs with cubic phase and diameter range 10-22 nm were monodispersed over the polymeric surface. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) investigation demonstrated that the AuNPs decorated Pth greatly improved the electrocatalytic performance compared with pure Pth modified GCE. This extraordinary electrochemical property is attributed to the synergistic coupling effect between AuNPs and Pth. The mechanistic analysis using CV voltammograms measured in varying scan rates revealed irreversible diffusion-controlled kinetics involving four-electron (4e(-)) transfer process of hydrazine oxidation. In amperometric (i-t) detection, the proposed sensor showed high sensitivity 0.1817 lAlMcm(-)2 and a low detection limit 0.77 lM (S/N = 3) over the concentration range 1-963 lM. Moreover, this proposed nanocomposite-based sensor was highly selective toward hydrazine in the presence of common interfering species, especially in high concentrations of sugars (e.g. glucose, sucrose, fructose, and galactose) and exhibited promising analytical results of recovery tests in water samples with acceptable recovery with a relative standard deviation less than 5%.(C) 2022 The Author(s). Published by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页数:13
相关论文