Effects of misalignment between transmission and emission scans on attenuation-corrected cardiac SPECT

被引:0
|
作者
Matsunari, I
Böning, G
Ziegler, SI
Kosa, I
Nekolla, SG
Ficaro, EP
Schwaiger, M
机构
[1] Tech Univ Munich, Nukl Med Klin & Poliklin, Klinikum Rechts Isar, D-81675 Munich, Germany
[2] Univ Michigan, Med Ctr, Dept Internal Med, Div Nucl Med, Ann Arbor, MI 48109 USA
关键词
attenuation correction; SPECT; transmission; emission scans; misalignment;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Misalignment between transmission and emission scans in attenuation-corrected (AC) cardiac SPECT can introduce errors of measured activity, The severity of these errors, however, has not yet been fully elucidated, Methods: We performed a phantom measurement as well as a study of patients with low likelihood of coronary artery disease. Transmission and emission scans were acquired using a triple-head SPECT system with a collimated Am-241 line source and an offset fanbeam collimator, The left ventricular myocardium was divided into five segments, and the mean regional activity was calculated for each segment using a semiquantitative polar map approach. Misalignment between transmission and emission data was created by shifting the emission data along the x, y or z axis, Results: In the heart phantom, a shift between the transmission and emission data produced a decrease or increase in relative regional activity in each segment resulting in heterogeneous activity distribution, A 7-mm (I-pixel) shift produced up to 15% change in relative regional activity, suggesting that even a small misalignment between transmission and emission data can produce serious errors in measured activity, In the clinical data, the effects of misalignment were less significant than those observed in the phantom data but were still measurable and visually identifiable. Conclusion: The results indicate that a small misalignment between the transmission and emission data can produce serious errors in measured activity, and, thus, geometrical precision is essential for accurate diagnosis of AC SPECT images.
引用
收藏
页码:411 / 416
页数:6
相关论文
共 50 条
  • [1] Clinical review of attenuation-corrected cardiac SPECT
    James R. Corbett
    Edward P. Ficaro
    Journal of Nuclear Cardiology, 1999, 6 : 54 - 68
  • [2] A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT introduced by misalignment between emission scan and CT-derived attenuation maps
    Fricke, H
    Fricke, E
    Weise, R
    Kammeier, A
    Lindner, O
    Burchert, W
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (10) : 1619 - 1625
  • [3] Effects of attenuation map accuracy on attenuation-corrected micro-SPECT images
    Chao Wu
    Hugo A Gratama van Andel
    Peter Laverman
    Otto C Boerman
    Freek J Beekman
    EJNMMI Research, 3
  • [4] Effects of attenuation map accuracy on attenuation-corrected micro-SPECT images
    Wu, Chao
    van Andel, Hugo A. Gratama
    Laverman, Peter
    Boerman, Otto C.
    Beekman, Freek J.
    EJNMMI RESEARCH, 2013, 3 : 1 - 11
  • [5] Problems created in attenuation-corrected SPECT images by artifacts in attenuation maps: A simulation study
    Celler, A
    Dixon, KL
    Chang, Z
    Blinder, S
    Powe, J
    Harrop, R
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (02) : 335 - 343
  • [6] Clinical implication of down-scatter in attenuation-corrected myocardial SPECT
    Almquist, H
    Arheden, H
    Arvidsson, AH
    Pahlm, O
    Palmer, J
    JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (04) : 406 - 411
  • [7] Clinical implication of down-scatter in attenuation-corrected myocardial SPECT
    Helén Almquist
    Håkan Arheden
    Ann-Helen Arvidsson
    Olle Pahlm
    John Palmer
    Journal of Nuclear Cardiology, 1999, 6 : 406 - 411
  • [8] Cause of apical thinning on attenuation-corrected myocardial perfusion SPECT
    Okuda, Koichi
    Nakajima, Kenichi
    Matsuo, Shinro
    Wakabayashi, Hiroshi
    Taki, Junichi
    Kinuya, Seigo
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (11) : 1033 - 1039
  • [10] Comparative Accuracy of CT Attenuation-Corrected and Non-Attenuation-Corrected SPECT Myocardial Perfusion Imaging
    Sharma, Punit
    Patel, Chetan D.
    Karunanithi, Sellam
    Maharjan, Sagar
    Malhotra, Arun
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (04) : 332 - 338