A semi-automated, microplate version of the SOS Chromotest for the analysis of complex environmental extracts

被引:33
作者
White, PA
Rasmussen, JB
Blaise, C
机构
[1] MCGILL UNIV, DEPT BIOL, MONTREAL, PQ H3A 1B1, CANADA
[2] ENVIRONM CANADA, ST LAWRENCE CTR, MONTREAL, PQ H2Y 2E7, CANADA
来源
MUTATION RESEARCH-ENVIRONMENTAL MUTAGENESIS AND RELATED SUBJECTS | 1996年 / 360卷 / 01期
基金
加拿大自然科学与工程研究理事会;
关键词
SOS Chromotest; genotoxicity; complex mixture; automation;
D O I
10.1016/S0165-1161(96)90237-X
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Environmental monitoring for genotoxicity requires that a large number of measurements be made across space and time. This requirement demands a rapid and efficient bioassay system. The SOS Chromotest is a rapid, efficient bacterial system for the detection of DNA damaging agents, Over 100 publications have described its use on a variety of samples. Relatively few studies have used the test to examine complex mixtures. Effective testing of complex samples poses a variety of problems. Although solutions have been proposed, few have validated the resulting protocol. In this work we present a semi-automated microplate version of the SOS Chromotest for the examination of complex mixtures, Experiments were conducted to determine the optimal cell concentration, exposure time, substrate conversion time and S9 enzyme concentration. The performance of the method was evaluated using 6 reference genotoxins and 3 complex mixtures. The complex mixtures examined are extracts of diesel particulate matter, urban dust and coal tar. The results obtained indicate that optimal responses often require fewer cells (approximate to 5-10 x 10(6) CFU/ml) and a longer exposure (3 h) than that recommended in the original protocol. Interfering effects of colored and turbid samples are removed using centrifugation and initial optical density readings taken 60 min after cell resuspension and lysis, The performance of the established protocol was evaluated using mitomycin C and benzo[a]pyrene results for 207 microplates and solvent control results for 293 microplates, The results indicate that the established method is accurate, sensitive and precise, Coefficient of variation on mean SOSIP values for mitomycin C and benzol[a]pyrene are < 5%. Solvent control data indicate that the standard threshold for determination of a positive response (induction factor > 1.5) is excessively conservative, All liquid transfers were automated using the Biomek(TM) automated laboratory workstation. Automation permits a throughput of up to 72 samples per day and maintains excellent precision and accuracy.
引用
收藏
页码:51 / 74
页数:24
相关论文
共 121 条
[1]   CARCINOGENS ARE MUTAGENS - SIMPLE TEST SYSTEM COMBINING LIVER HOMOGENATES FOR ACTIVATION AND BACTERIA FOR DETECTION [J].
AMES, BN ;
DURSTON, WE ;
YAMASAKI, E ;
LEE, FD .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1973, 70 (08) :2281-2285
[2]   METHODS FOR DETECTING CARCINOGENS AND MUTAGENS WITH SALMONELLA-MAMMALIAN-MICROSOME MUTAGENICITY TEST [J].
AMES, BN ;
MCCANN, J ;
YAMASAKI, E .
MUTATION RESEARCH, 1975, 31 (06) :347-363
[3]  
[Anonymous], TOXICITY ASSESSMENT, DOI [10.1002/tox.2540020203, DOI 10.1002/TOX.2540020203]
[5]  
ASTHANA RK, 1992, B ENVIRON CONTAM TOX, V48, P45, DOI 10.1007/BF00197482
[6]   GENOTOXIC ACTIVITY OF SOME MYCOTOXINS USING THE SOS CHROMOTEST [J].
AUFFRAY, Y ;
BOUTIBONNES, P .
MYCOPATHOLOGIA, 1987, 100 (01) :49-53
[7]   CHARACTERIZATION OF BETA-GALACTOSIDASES FROM THE GERMINATING-SEEDS OF VIGNA-SINENSIS [J].
BISWAS, TK .
PHYTOCHEMISTRY, 1987, 26 (02) :359-364
[8]   BIOLOGICAL TESTING - DEVELOPMENT, APPLICATION, AND TRENDS IN CANADIAN ENVIRONMENTAL-PROTECTION LABORATORIES [J].
BLAISE, C ;
SERGY, G ;
WELLS, P ;
BERMINGHAM, N ;
VANCOILLIE, R .
TOXICITY ASSESSMENT, 1988, 3 (04) :385-406
[9]   TESTING HUMAN FECAL EXTRACTS FOR GENOTOXIC ACTIVITY WITH THE SOS CHROMOTEST - THE IMPORTANCE OF CONTROLLING FOR FECAL ENZYME-ACTIVITY [J].
BOSWORTH, D ;
VENITT, S .
MUTAGENESIS, 1986, 1 (02) :143-149
[10]   GENOTOXICITY STUDIES IN SEMICONDUCTOR INDUSTRY .1. IN-VITRO MUTAGENICITY AND GENOTOXICITY STUDIES OF WASTE SAMPLES RESULTING FROM PLASMA-ETCHING [J].
BRAUN, R ;
HUTTNER, E ;
MERTEN, H ;
RAABE, F .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1993, 39 (03) :309-322