A fluorescent immunochromatographic test using immunoliposomes for detecting microcystins and nodularins

被引:36
作者
Khreich, Nathalie [6 ]
Lamourette, Patricia [6 ]
Lagoutte, Bernard [5 ]
Ronco, Cyril [2 ,3 ,4 ]
Franck, Xavier [3 ,4 ]
Creminon, Christophe [6 ]
Volland, Herve [1 ,6 ]
机构
[1] CEA Saclay, DSV iBiTec S SPI, Lab Etud & Rech Immunoanal, F-91191 Gif Sur Yvette, France
[2] Univ Rouen, IRCOF, F-76130 Mont St Aignan, France
[3] CNRS, COBRA, Equipe Chim Bioorgan, UMR 6014, F-76130 Mont St Aignan, France
[4] CNRS, COBRA, Equipe Chim Bioorgan, FR 3038, F-76130 Mont St Aignan, France
[5] CEA, iBiTeC S, CNRS, URA 2096, F-91191 Gif Sur Yvette, France
[6] CEA, iBiTeC S, Serv Pharmacol & Immunoanal, Lab Etud & Rech Immunoanal, F-91191 Gif Sur Yvette, France
关键词
Microcystins; Nodularins; Monoclonal antibody; Immunoliposomes; Immunochromatographic test; Enzyme immunoassay; GANGLIOSIDE-LIPOSOME IMMUNOASSAY; CYANOBACTERIAL HEPATOTOXINS; ALACHLOR DETERMINATION; PROTEIN PHOSPHATASE-1; MASS-SPECTROMETRY; WATER SAMPLES; ASSAY; LR; CHROMATOGRAPHY; TOXIN;
D O I
10.1007/s00216-009-3348-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microcystins (MCs), a group of cyclic heptapeptides produced by common cyanobacteria (blue green algae), cause both acute and chronic toxicity. Due to their toxicity, constant monitoring in drinking water, recreational waters as well as other potential exposure through ingestion of contaminated sea food, is very important. In this context, an immunochromatographic test (ICT) using a monoclonal antibody labeled with fluorescent liposomes (immunoliposomes) as tracer was developed, allowing a rapid and simple detection of a large number of MC and nodularin variants in field samples. The present ICT using immunoliposomes proved to be ten times more sensitive than the ICT using colloidal gold for labeling. To achieve quantitative measurement, this ICT was improved by including a stable signal on the control band allowing the expression of the results as a ratio of the fluorescence signals of the specific band versus the control band (SB/CB). Very low concentrations of MC-LR were detected in the analysis buffer (0.06 ng/ml), well below the guideline value of 1 ng/ml proposed by the World Health Organization (WHO), with a dynamic range from 0.06 to 1.5 ng/ml of MC-LR. This method was also validated using a hand-held commercial fluorometer (from ESE (R)), providing the same performances obtained via the analysis station (from Kodak (R)) used in our laboratory. Repeatability tests performed with both devices showed good accuracy (CV<13%). Furthermore, quantification of MCs in natural samples (water bloom and Microcystis culture) was achieved using ICT, leading to similar results obtained via an EIA previously described. All these results demonstrate that this new fluorescent ICT could be used not only as a sensitive detection tool but also to quantify MCs in field samples.
引用
收藏
页码:1733 / 1742
页数:10
相关论文
共 33 条
[1]   Ganglioside-liposome immunoassay for the ultrasensitive detection of cholera toxin [J].
Ahn-Yoon, S ;
DeCory, TR ;
Baeumner, AJ ;
Durst, RA .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2256-2261
[2]   Ganglioside-liposome immunoassay for the detection of botulinum toxin [J].
Ahn-Yoon, S ;
DeCory, TR ;
Durst, RA .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (01) :68-75
[3]   Analysis of cyanobacterial hepatotoxins in water samples by microbore reversed-phase liquid chromatography-electrospray ionisation mass spectrometry [J].
Barco, M ;
Rivera, J ;
Caixach, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 959 (1-2) :103-111
[4]   CYANOBACTERIA SECONDARY METABOLITES - THE CYANOTOXINS [J].
CARMICHAEL, WW .
JOURNAL OF APPLIED BACTERIOLOGY, 1992, 72 (06) :445-459
[5]  
CARMICHAEL WW, 1997, ADV BOT RES INCORPOR
[6]   Recovery of MC-LR in fish liver tissue [J].
Ernst, B ;
Dietz, L ;
Hoeger, SJ ;
Dietrich, DR .
ENVIRONMENTAL TOXICOLOGY, 2005, 20 (04) :449-458
[7]   The toxicity of cyanobacterial toxins in the mouse: I Microcystin-LR [J].
Fawell, JK ;
Mitchell, RE ;
Everett, DJ ;
Hill, RE .
HUMAN & EXPERIMENTAL TOXICOLOGY, 1999, 18 (03) :162-167
[8]   Determination of cyanobacterial hepatotoxins directly in water using a protein phosphatase inhibition assay [J].
Heresztyn, T ;
Nicholson, BC .
WATER RESEARCH, 2001, 35 (13) :3049-3056
[9]   Detection of Staphylococcus enterotoxin B using fluorescent immunoliposomes as label for immunochromatographic testing [J].
Khreich, Nathalie ;
Lamourette, Patricia ;
Boutal, Herve ;
Devilliers, Karine ;
Creminon, Christophe ;
Volland, Herve .
ANALYTICAL BIOCHEMISTRY, 2008, 377 (02) :182-188
[10]   A highly sensitive competitive enzyme immunoassay of broad specificity quantifying microcystins and nodularins in water samples [J].
Khreich, Nathalie ;
Lamourette, Patricia ;
Renard, Pierre-Yves ;
Clave, Guillaume ;
Fenaille, Francois ;
Creminon, Christophe ;
Volland, Herve .
TOXICON, 2009, 53 (05) :551-559