Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography

被引:91
作者
Holmes, Niall [1 ]
Tierney, Tim M. [2 ]
Leggett, James [1 ]
Boto, Elena [1 ]
Mellor, Stephanie [2 ]
Roberts, Gillian [1 ]
Hill, Ryan M. [1 ]
Shah, Vishal [3 ]
Barnes, Gareth R. [2 ]
Brookes, Matthew J. [1 ]
Bowtell, Richard [1 ]
机构
[1] Univ Nottingham, Sch Phys & Astron, Sir Peter Mansfield Imaging Ctr, Nottingham NG7 2RD, England
[2] UCL, Inst Neurol, Wellcome Ctr Human Neuroimaging, 12 Queen Sq, London WC1N 3AR, England
[3] QuSpin Inc, 331 South 104th St,Suite 130, Louisville, CO 80027 USA
基金
英国工程与自然科学研究理事会; 美国国家卫生研究院; 英国医学研究理事会;
关键词
DESIGN; PERFORMANCE;
D O I
10.1038/s41598-019-50697-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To allow wearable magnetoencephalography (MEG) recordings to be made on unconstrained subjects the spatially inhomogeneous remnant magnetic field inside the magnetically shielded room (MSR) must be nulled. Previously, a large bi-planar coil system which produces uniform fields and field gradients was used for this purpose. Its construction presented a significant challenge, six distinct coils were wound on two 1.6 x 1.6 m(2) planes. Here, we exploit shared coil symmetries to produce coils simultaneously optimised to generate homogenous fields and gradients. We show nulling performance comparable to that of a six-coil system is achieved with this three-coil system, decreasing the strongest field component B-x by a factor of 53, and the strongest gradient dB(x)/dz by a factor of 7. To allow the coils to be used in environments with temporally-varying magnetic interference a dynamic nulling system was developed with a shielding factor of 40 dB at 0.01 Hz. Reducing the number of coils required and incorporating dynamic nulling should allow for greater take-up of this technology. Interactions of the coils with the high-permeability walls of the MSR were investigated using a method of images approach. Simulations show a degrading of field uniformity which was broadly consistent with measured values. These effects should be incorporated into future designs.
引用
收藏
页数:15
相关论文
共 50 条
[41]   Simulation and Verification of Magnetic Field Gradient Waveforms in the Presence of a Metallic Vessel in Magnetic Resonance Imaging [J].
Goora, Frederic G. ;
Hui, Han ;
Colpitts, Bruce G. ;
Balcom, Bruce J. .
IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (09) :2440-2448
[42]   Magnetic Field Analysis of Permanent Magnet Array for Planar Motor Based on Equivalent Magnetic Charge Method [J].
Rui, Huang ;
Jian, Feng .
PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, :3966-3970
[43]   Analytical computation of magnetic field in coil-dominated superconducting quadrupole magnets based on racetrack coils [J].
Shen, Chuang ;
Zhu, Ying-Shun ;
Chen, Fu-San .
NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (04)
[44]   The Magnetic Field Stability of Double-Slit Jointless Stacked Pancake Coils After Thermal Quench [J].
Pan, Yunhao ;
Wu, Wei ;
Qiu, Derong ;
Sheng, Jie ;
Hong, Zhiyong ;
Jin, Zhijian .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
[45]   Computational modeling of magnetic nanoparticle targeting to stent surface under high gradient field [J].
Wang, Shunqiang ;
Zhou, Yihua ;
Tan, Jifu ;
Xu, Jiang ;
Yang, Jie ;
Liu, Yaling .
COMPUTATIONAL MECHANICS, 2014, 53 (03) :403-412
[46]   High-Field Gradient Permanent Micromagnets for Targeted Drug Delivery with Magnetic Nanoparticles [J].
Zablotskii, Vitalii ;
Martin Pastor, Jose ;
Larumbe, Silvia ;
Ignacio Perez-Landazabal, Jose ;
Recarte, Vicente ;
Gomez-Polo, Cristina .
8TH INTERNATIONAL CONFERENCE ON THE SCIENTIFIC AND CLINICAL APPLICATIONS OF MAGNETIC CARRIERS, 2010, 1311 :152-157
[47]   Accuracy of the Magnetic Field Gradient Waveform Monitor Technique and Consequent Accuracy of Pre-Equalized Gradient Waveform [J].
Goora, Frederic G. ;
Balcom, Bruce J. .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2016, 46 (02) :67-80
[48]   Bi-stable magnetoelectric data flip-flop triggered by magnetic field [J].
Li, Kang ;
Zhang, Jitao ;
Zhang, Qingfang ;
Filippov, D. A. ;
Wu, Jie ;
Tao, Jiagui ;
Jiang, Liying ;
Cao, Lingzhi ;
Srinivasan, Gopalan .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2021, 32 (02) :2249-2257
[49]   Magnetic Field Mitigation in Dynamic Wireless Power Transfer Systems by Double Sided LCC Compensation [J].
Campi, Tommaso ;
Cruciani, Silvano ;
Maradei, Francesca ;
Feliziani, Mauro .
IEEE ACCESS, 2024, 12 :109750-109758
[50]   Electrically conducting sandwich cylinder with a planar lattice core under prescribed eigenstrain and magnetic field [J].
Akbarzadeh, A. H. ;
Fu, J. W. ;
Liu, L. ;
Chen, Z. T. ;
Pasini, D. .