Fiber-optic Mach-Zehnder interferometer measuring electro-optic coefficients of poled polymers

被引:0
|
作者
Wang, YP [1 ]
Chen, JP [1 ]
Li, XW [1 ]
Hong, JX [1 ]
Ye, AL [1 ]
机构
[1] Shanghai Jiao Tong Univ, State Key Lab Local Fiber Opt Commun Networks & A, Shanghai 200030, Peoples R China
关键词
optical communications devices poled polymers; electro-optic coefficient; fiber-optic Mach-Zehnder interferometer;
D O I
10.1117/12.572411
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is proposed and demonstrated that the fiber-optic Mach-Zehnder (MZ) interferometry can measure accurately the elector-optic (EO) coefficients of, not only the polymer thin film. but also the polymer waveguide. Furthermore, the tensor components, both r(13) and r(33), of the EO coefficient can be measured simultaneously. In contrast with the free space MZ interferometer. the fiber-optic MZ interferometer owns some advantages, such as fewer devices, simple experiment configuration, easy operation, and good stability. The most outstanding advantage is that the second electrode need not be fabricated on the top of the polymer thin film. So, the measurement system is especially suitable to measure E-O coefficients of the polymer samples on trial. The closed loop control system of the phase bias of the MZ interferometer decreases the requirement of the environment stability and increases the measurement precision.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 50 条
  • [1] Measuring electro-optic coefficients of poled polymers using fiber-optic Mach-Zehnder interferometer
    Wang, YP
    Chen, JP
    Li, XW
    Hong, JX
    Zhang, XH
    Zhou, JH
    Ye, AL
    APPLIED PHYSICS LETTERS, 2004, 85 (21) : 5102 - 5103
  • [2] Integrated fiber Mach-Zehnder interferometer for electro-optic switching
    Fokine, M
    Nilsson, LE
    Claesson, Å
    Berlemont, D
    Kjellberg, L
    Krummenacher, L
    Margulis, W
    OPTICS LETTERS, 2002, 27 (18) : 1643 - 1645
  • [3] Fiber-optic seismometer on the basis of Mach-Zehnder interferometer
    Kamenev, Oleg T.
    Kulchin, Yuri N.
    Petrov, Yuri S.
    Khiznyak, Ruslan V.
    Romashko, Roman V.
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 244 : 133 - 137
  • [4] Research of Mach-Zehnder interferometer in electro-optic integrated accelerometer
    Zhang Yanjun
    Wei Jianxia
    Chen Caihe
    Wu Bo
    PASSIVE COMPONENTS AND FIBER-BASED DEVICES IV, PTS 1 AND 2, 2007, 6781
  • [5] Intrusion Sensor Using Fiber-Optic Mach-Zehnder Interferometer
    Park, Hyoung Jun
    Song, Minho
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2006, 26 (04) : 255 - 259
  • [6] Mach-Zehnder interferometer based fiber-optic nitrate sensor
    Al Noman, Abdullah
    Dash, Jitendra Narayan
    Cheng, Xin
    Tam, Hwa-Yam
    Yu, Changyuan
    OPTICS EXPRESS, 2022, 30 (21) : 38966 - 38974
  • [7] Distributed fiber-optic sensor with a ring Mach-Zehnder interferometer
    Sun, Qizhen
    Liu, Deming
    Liu, Hairong
    Shum, P.
    PASSIVE COMPONENTS AND FIBER-BASED DEVICES IV, PTS 1 AND 2, 2007, 6781
  • [8] Electro-optic measurements using a Mach-Zehnder interferometer with domain reversals
    Samson, S
    Li, WH
    Tavlykaev, R
    Ramaswamy, R
    PHOTONIC COMPONENT ENGINEERING AND APPLICATIONS, 1996, 2749 : 186 - 194
  • [9] Study on the measurement of the complex electro-optic coefficients of poled dye-doped polymer films using a Mach-Zehnder interferometer
    Cheng, X.M.
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2001, 12 (04): : 361 - 364
  • [10] Polymeric electro-optic Mach-Zehnder switches
    Thackara, JI
    Chon, JC
    Bjorklund, GC
    Volksen, W
    Burland, DM
    APPLIED PHYSICS LETTERS, 1995, 67 (26) : 3874 - 3876