A Numerical Investigation on Thermal Gradients and Stresses in High Temperature PEM Fuel Cell During Start-up

被引:26
作者
Varghese, Geethu [1 ]
Babu, Venkatesh K. P. [1 ]
Joseph, Thadathil Varghese [1 ]
Chippar, Purushothama [2 ]
机构
[1] CHRIST Deemed Be Univ, Bengaluru 560029, India
[2] Affiliated Visvesvaraya Technol Univ, St Joseph Engn Coll, Vamanjoor 575028, Mangaluru, India
关键词
Fuel cell; Start-up; Thermal stress; Finite element analysis; Fluid-structure interaction; PERFORMANCE; MEMBRANES; RESISTANCE; MIGRATION; DIESEL; MODEL;
D O I
10.1016/j.ijheatmasstransfer.2021.121365
中图分类号
O414.1 [热力学];
学科分类号
摘要
The High Temperature Polymer Electrolyte Fuel Cell (HT-PEMFC) stacks using polybenzimidazole (PBI) based membranes have an inability to internally heat up at low temperatures to their nominal operating temperature (160 degrees C-180 degrees C) during the start-up process. Several strategies, such as direct electrical heating, coolant/gas channel heating, catalytic hydrogen-oxygen combustion, etc., are proposed in the literature to assist the heating for quick start-up situations. However, little knowledge exists on the transient thermomechanical stresses induced during the start-up heating process due to non-uniformity in heat supply and disparity in thermal properties of the cell components. The objective of the present research is to analyze the thermal gradients and thermal stresses developed in the HT-PEMFC structure during the start-up with various heating methods discussed in the literature, as well as during the cell operation by exploiting the Fluid-Structure Interaction (FSI) approach. The use of polyalkylene glycol (Fragoltherm S-15-A) based Heat Transfer Fluid (HTF) in the coolant channel has substantially improved the start-up time due to the high Nusselt number. However, a significant gradient in temperature distribution is observed during the preheating process, which resulted in great inhomogeneous stresses in the membrane, particularly in the in-plane direction. Interestingly, the degree of uniformity in membrane current density distribution during cell operation is increased. A detailed heat analysis in the cell showed that the heat generated in the cell due to electrochemical reactions is sufficient to raise the cell temperature from 120 degrees C to operating temperature in a short time. Being subjected to a compressive stress of above 40 MPa, which is higher than the ultimate strength of a typical acid doped PBI membrane, the electrolyte is the most vulnerable component during the start-up. Hence, to inhibit the concomitant effect on cell performance and degradation, a novel start-up strategy should be implemented. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:14
相关论文
共 51 条
[1]   Modelling and evaluation of heating strategies for high temperature polymer electrolyte membrane fuel cell stacks [J].
Andreasen, Soren Juhl ;
Kaer, Soren Knudsen .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (17) :4655-4664
[2]  
[Anonymous ASM International ASM International], ASM Ready Reference: Thermal Properties of Metals, P9
[3]   A comprehensive review of PBI-based high temperature PEM fuel cells [J].
Araya, Samuel Simon ;
Zhou, Fan ;
Liso, Vincenzo ;
Sahlin, Simon Lennart ;
Vang, Jakob Rabjerg ;
Thomas, Sobi ;
Gao, Xin ;
Jeppesen, Christian ;
Kaer, Soren Knudsen .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (46) :21310-21344
[4]   Modelling CO poisoning and O2 bleeding in a PEM fuel cell anode [J].
Baschuk, JJ ;
Li, XG .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (12) :1095-1116
[5]   Determination of Anion Transference Number and Phosphoric Acid Diffusion Coefficient in High Temperature Polymer Electrolyte Membranes [J].
Becker, Hans ;
Reimer, Uwe ;
Aili, David ;
Cleemann, Lars N. ;
Jensen, Jens Oluf ;
Lehnert, Werner ;
Li, Qingfeng .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (10) :F863-F869
[6]   Probing phosphoric acid redistribution and anion migration in polybenzimidazole membranes [J].
Becker, Hans ;
Cleemann, Lars Nilausen ;
Aili, David ;
Jensen, Jens Oluf ;
Li, Qingfeng .
ELECTROCHEMISTRY COMMUNICATIONS, 2017, 82 :21-24
[7]   Micro-cogeneration application of a high-temperature PEM fuel cell stack operated with polybenzimidazole based membranes [J].
Budak, Yagmur ;
Devrim, Yilser .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (60) :35198-35207
[8]  
C. A. P. E. M. F. Cell and P. Classification, 2005, METHOD APPARATUS COL
[9]  
Cary W., 2002, COLD START PEM FUEL
[10]   A two-phase model of an intermediate temperature PEM fuel cell [J].
Cheddie, Denver F. ;
Munroe, Norman D. H. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (07) :832-841