Capsular Ligament Function After Total Hip Arthroplasty

被引:23
作者
van Arkel, Richard J. [1 ,2 ]
Ng, K. C. Geoffrey [1 ,2 ]
Muirhead-Allwood, Sarah K. [1 ,3 ]
Jeffers, Jonathan R. T. [1 ,2 ]
机构
[1] Imperial Coll London, London, England
[2] Imperial Coll London, Dept Mech Engn, London, England
[3] London Hip Unit, London, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
DIRECT ANTERIOR APPROACH; FINITE-ELEMENT-ANALYSIS; SOFT-TISSUE REPAIR; POSTERIOR-APPROACH; POSTEROLATERAL APPROACH; COORDINATE SYSTEM; SURGICAL APPROACH; FEMORAL-HEAD; SAFE ZONE; IN-VITRO;
D O I
10.2106/JBJS.17.00251
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The hip joint capsule passively restrains extreme range of motion, protecting the native hip against impingement, dislocation, and edge-loading. We hypothesized that following total hip arthroplasty (THA), the reduced femoral head size impairs this protective biomechanical function. Methods: In cadavers, THA was performed through the acetabular medial wall, preserving the entire capsule, and avoiding the targeting of a particular surgical approach. Eight hips were examined. Capsular function was measured by rotating the hip in 5 positions. Three head sizes (28, 32, and 36 mm) with 3 neck lengths (anatomical 0, 15, and 110 mm) were compared. Results: Internal and external rotation range of motion increased following THA, indicating late engagement of the capsule and reduced biomechanical function (p < 0.05). Internal rotation was affected more than external. Increasing neck length reduced this hypermobility, while too much lengthening caused nonphysiological restriction of external rotation. Larger head sizes only slightly reduced hypermobility. Conclusions: Following THA, the capsular ligaments were unable to wrap around the reduced-diameter femoral head to restrain extreme range of motion. The posterior capsule was the most affected, indicating that native posterior capsule preservation is not advantageous, at least in the short term. Insufficient neck length could cause capsular dysfunction even if native ligament anatomy is preserved, while increased neck length could overtighten the anterior capsule.
引用
收藏
页数:10
相关论文
共 50 条
[1]   Clinical biomechanics of instability related to total knee arthroplasty [J].
Athwal, Kiron K. ;
Hunt, Nicola C. ;
Davies, Andrew J. ;
Deehan, David J. ;
Amis, Andrew A. .
CLINICAL BIOMECHANICS, 2014, 29 (02) :119-128
[2]   Prospective Randomized Study of Direct Anterior vs Postero-Lateral Approach for Total Hip Arthroplasty [J].
Barrett, William P. ;
Turner, Shelly E. ;
Leopold, John P. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (09) :1634-1638
[3]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[4]   Standardized Loads Acting in Hip Implants [J].
Bergmann, Georg ;
Bender, Alwina ;
Dymke, Joern ;
Duda, Georg ;
Damm, Philipp .
PLOS ONE, 2016, 11 (05)
[5]   Dislocation following total hip replacement CAUSES AND CURES [J].
Brooks, P. J. .
BONE & JOINT JOURNAL, 2013, 95B (11) :67-69
[6]   Surgical Technique: A Simple Soft-tissue-only Repair of the Capsule and External Rotators in Posterior-approach THA [J].
Browne, James A. ;
Pagnano, Mark W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :511-515
[7]   Effect of Head Diameter on Passive and Active Dynamic Hip Dislocation [J].
Bunn, Adam ;
Colwell, Clifford W., Jr. ;
D'Lima, Darryl D. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (11) :1525-1531
[8]   Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[9]  
Charles Mark N, 2005, Instr Course Lect, V54, P131
[10]   The effect of posterior capsulorrhaphy in primary total hip arthroplasty - A prospective randomized study [J].
Chiu, FY ;
Chen, CM ;
Chung, TY ;
Lo, WH ;
Tain-Hsiung-Chen .
JOURNAL OF ARTHROPLASTY, 2000, 15 (02) :194-199