The diagnosis of breast implant rupture:: MRI findings compared with findings at explantation
被引:68
作者:
Hölmich, LR
Vejborg, I
Conrad, C
Sletting, S
McLaughlin, JK
机构:
[1] Danish Canc Soc, Inst Canc Epidemiol, DK-2100 Copenhagen, Denmark
[2] Herlev Univ Hosp, Dept Plast Surg, DK-2730 Herlev, Denmark
[3] Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
[4] Hjorring Hosp, Dept Radiol, DK-9800 Hjorring, Denmark
[5] Herlev Univ Hosp, Dept Radiol, DK-2730 Herlev, Denmark
[6] Int Epidemiol Inst, Rockville, MD 20850 USA
[7] Vanderbilt Univ, Med Ctr, Dept Med, Vanderbilt Ingram Canc Ctr, Nashville, TN 37232 USA
关键词:
breast;
MR;
implant;
prosthesis;
silicone;
D O I:
10.1016/j.ejrad.2004.03.012
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Study objective: The aim of this study was to evaluate the accuracy of Magnetic Resonance Imaging (MRI) as performed according to a strict study protocol in diagnosing rupture of silicone breast implants. Material and methods: The study population consisted of 64 women with 118 implants, who had participated in either one or two study MRI examinations, aiming at determining the prevalence and incidence of silent implant rupture, respectively, and who subsequently underwent explantation. Implant rupture status was determined by four independent readers and a consensus diagnosis of either rupture (intracapsular or extracapsular), possible rupture or intact implant was then obtained. Strict predetermined rupture criteria were applied as described in this report and findings at surgery were abstracted in a standardised manner and results compared. Results: At MRI, 66 implants were diagnosed as ruptured, nine as possibly ruptured and 43 as intact. Among the ruptured implants, 27 were categorized as extracapsular. At surgery, on average 297 days after the MRI, 65 of the 66 rupture diagnoses were confirmed, as were 20 of the cases with extracapsular silicone. Eight of the nine possibly ruptured implants were in fact ruptured at surgery. Thirty-four of the 43 intact implants were described as intact at surgery. When categorising possible ruptures as ruptures, there were one false positive and nine false negative rupture diagnoses at MRI yielding an accuracy of 92%, a sensitivity of 89%, and a specificity of 97%. Correspondingly, the predictive value of a positive MRI examination was 99% and the predictive value of a negative MRI examination was 79%. Conclusions: We conclude that MRI is highly accurate for identification of silicone breast implant rupture, with a high sensitivity and specificity when evaluation of images are based on presence of well-defined rupture criteria. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:213 / 225
页数:13