Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque

被引:162
作者
Brand, JC [1 ]
Pienkowski, D [1 ]
Steenlage, E [1 ]
Hamilton, D [1 ]
Johnson, DL [1 ]
Caborn, DNM [1 ]
机构
[1] Univ Kentucky, Sch Med, Lexington, KY 40536 USA
关键词
D O I
10.1177/03635465000280051501
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to determine whether bone mineral density of the host bone, measured using conventional dual photon absorptiometry techniques, and insertion torque can predict part of the ultimate failure strength of interference screw fixation of quadrupled hamstring tendon grafts. The semitendinosus and gracilis tendons were harvested from 10 human cadaveric knees, mean age 66.5 years (range, 53 to 81). The bone tunnel was sized within 0.5 mm of the graft. The graft was fixed with a biodegradable screw (7 x 25 mm for the femur, and 9 x 25 mm for the tibia) directly against the tendon and at the joint surfaces. Tibial fixation and femoral fixation were tested to failure using a materials testing system. Bone mineral density was measured in the metaphyseal region of the tibia and femur. The results of multiple regression analyses showed that both insertion torque and bone mineral density were related to the maximum load the graft withstood. These two variables explained 77.1% of the maximum load observed. We concluded that bone mineral density measurements of the host bone site are an important determinant of postoperative graft strength and thus have an important, but previously unrecognized, clinical role in establishing individual postsurgery rehabilitation protocols. Insertion torque in this study was a useful predictor of graft fixation strength.
引用
收藏
页码:705 / 710
页数:6
相关论文
共 14 条
  • [1] Is an anterior cruciate ligament reconstruction outcome age dependent?
    Barber, FA
    Elrod, BF
    McGuire, DA
    Paulos, LE
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1996, 12 (06) : 720 - 725
  • [2] Brand JC, 1999, ARTHROSCOPY, V15, P548
  • [3] Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: A comparison between a metal and a bioabsorbable interference screw
    Caborn, DNM
    Coen, M
    Neef, R
    Hamilton, D
    Nyland, J
    Johnson, DL
    [J]. ARTHROSCOPY, 1998, 14 (03): : 241 - 245
  • [4] Current trends in anterior cruciate ligament reconstruction Part II. Operative procedures and clinical correlations
    Fu, FH
    Bennett, CH
    Ma, CB
    Menetrey, J
    Lattermann, C
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) : 124 - 130
  • [5] Madsen O R, 1994, Osteoarthritis Cartilage, V2, P141, DOI 10.1016/S1063-4584(05)80064-0
  • [6] Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts
    Magen, HE
    Howell, SM
    Hull, ML
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (01) : 35 - 43
  • [7] Biomechanical consequences of replacement of the anterior cruciate ligament with a patellar ligament allograft .2. Forces in the graft compared with forces in the intact ligament
    Markolf, KL
    Burchfield, DM
    Shapiro, MM
    Cha, CW
    Finerman, GAM
    Slauterbeck, JL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (11) : 1728 - 1734
  • [8] BIOMECHANICAL ANALYSIS OF HUMAN LIGAMENT GRAFTS USED IN KNEE-LIGAMENT REPAIRS AND RECONSTRUCTIONS
    NOYES, FR
    BUTLER, DL
    GROOD, ES
    ZERNICKE, RF
    HEFZY, MS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (03) : 344 - 352
  • [9] Peine R, 1998, ARTHROSCOPY, V14, P456
  • [10] Comparison of failure strength between metallic and absorbable interference screws - Influence of insertion torque, tunnel-bone block gap, bone mineral density, and interference
    Pena, F
    Grontvedt, T
    Brown, GA
    Aune, AK
    Engebretsen, L
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (03) : 329 - 334