Lyophilization cycle development for a high-concentration monoclonal antibody formulation lacking a crystalline bulking agent

被引:63
作者
Colandene, James D. [1 ]
Maldonado, Linda M. [1 ]
Creagh, Alma T. [1 ]
Vrettos, John S. [1 ]
Goad, Kenneth G. [1 ]
Spitznagel, Thomas M. [1 ]
机构
[1] Human Genome Sci Inc, Dept Pharmaceut Sci, Rockville, MD 20850 USA
关键词
lyophilization; freeze-drying; thermal analysis; calorimetry (DSC); glass transition; proteins; monoclonal antibody; protein formulation; FTIR; collapse;
D O I
10.1002/jps.20812
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
An efficient freeze-dry cycle was developed for a high concentration monoclonal antibody formulation lacking a crystalline bulking agent. The formulation, at multiple protein concentrations, was characterized using differential scanning calorimetry (DSC) and freeze-dry microscopy. At low protein concentrations the glass transition temperature of the maximally freeze-concentrated solution (T-g') determined by DSC was similar to the collapse temperature determined by freeze-dry microscopy. However, at higher protein concentrations, the difference between collapse temperature and T-g' became progressively larger. The difference between the onset temperature for collapse and the complete collapse temperature also became progressively larger as protein concentration increased. JMP (R) Design of Experiment studies were used to assess the effect of freezing rate, primary drying shelf temperature, and chamber pressure on primary drying product temperature, length of primary drying, and product quality attributes. Primary drying was shortened significantly by adjusting to conditions where the product temperature substantially exceeded Tg' without any apparent detrimental effect to the product. (C) 2006 Wiley-Liss, Inc.
引用
收藏
页码:1598 / 1608
页数:11
相关论文
共 13 条