Analytical Considerations in Nanoscale Flow Cytometry of Extracellular Vesicles to Achieve Data Linearity

被引:39
作者
Gomes, Janice [1 ,2 ]
Lucien, Fabrice [1 ,3 ,4 ]
Cooper, Tyler T. [5 ]
Kim, Yohan [1 ,3 ,4 ]
Williams, Karla C. [3 ,4 ]
Liao, XinYang [4 ]
Kaufman, Lauren [6 ]
Lagugne-Labarthet, Francois [6 ]
Kenyon, Oliver [7 ]
Boysen, Justin [8 ]
Kay, Neil E. [8 ]
McIntyre, Christopher W. [1 ,2 ]
Leong, Hon S. [1 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Pathol & Lab Med, London, ON, Canada
[2] London Hlth Sci Ctr, Kidney Clin Res Unit, London, ON, Canada
[3] Mayo Clin, Dept Urol, 9-01B,Guggenheim Bldg,200 First St SW, Rochester, MN 55905 USA
[4] Lawson Hlth Res Inst, Translat Prostate Canc Res Lab, London, ON, Canada
[5] Univ Western Ontario, Dept Physiol & Pharmacol, London, ON, Canada
[6] Univ Western Ontario, Dept Chem, London, ON, Canada
[7] Apogee Flow Syst Inc, Northwood, Herts, England
[8] Mayo Clin, Div Hematol, Rochester, MN USA
基金
加拿大自然科学与工程研究理事会;
关键词
cancer; microparticles; flow cytometry; NANOPARTICLE TRACKING ANALYSIS; PLATELET-DERIVED MICROPARTICLES; CIRCULATING MICROPARTICLES; ACTIVATED PLATELETS; VASCULAR-DISEASE; CANCER-PATIENTS; HUMAN BLOOD; PLASMA; STANDARDIZATION; EXOSOMES;
D O I
10.1055/s-0038-1668544
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Platelet microparticles (PMPs) and their abundance in the blood are a prognostic biomarker in thrombotic disorders and cancer. Nanoscale flow cytometry (nFC) is ideal for high-throughput analysis of PMPs but these clinical assays have not been developed previously. Objective This article demonstrates that nFC is a suitable technology to enumerate PMPs present in plasma samples in a clinical setting. Materials and Methods nFC was performed using the Apogee A50-Micro instrument. Instrument settings and acquisition parameters were developed with the use of fluorescent beads and plasma samples. Sample preparation and handling was also optimized. Results nFC allows for linear detection of particles between approximately 200 and 1,000 nm based on calibration beads and was dependent on dilution factor and flow rate. Linearity in event analysis as samples became more diluted was lost when events approximately 100 nm were gated while linearity was maintained despite dilution of sample in events larger than 200 nm in diameter. Higher flow rates lead to an under-estimation of events analysed per microlitre of analyte and this was more pronounced when plasma samples were not diluted more than 1/20x. Conclusion nFC offers multi-parametric analysis of PMPs when optimal calibration of acquisition and sample processing settings is performed. Analysis of plasmas from metastatic prostate cancer patients and leukaemia patients revealed that PMP levels were larger than 100 nm and were equally abundant in patients that responded to or failed androgen deprivation therapy or between patients representing different stages of leukaemia.
引用
收藏
页码:1612 / 1624
页数:13
相关论文
共 46 条
  • [41] Single vs. swarm detection of microparticles and exosomes by flow cytometry
    Van der Pol, E.
    Van Gemert, M. J. C.
    Sturk, A.
    Nieuwland, R.
    Van Leeuwen, T. G.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2012, 10 (05) : 919 - 930
  • [42] Absolute sizing and label-free identification of extracellular vesicles by flow cytometry
    van der Pol, Edwin
    de Rond, Leonie
    Coumans, Frank A. W.
    Gool, Elmar L.
    Boing, Anita N.
    Sturk, Auguste
    Nieuwland, Rienk
    van Leeuwen, Ton G.
    [J]. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2018, 14 (03) : 801 - 810
  • [43] Refractive Index Determination of Nanoparticles in Suspension Using Nanoparticle Tracking Analysis
    van der Pol, Edwin
    Coumans, Frank A. W.
    Sturk, Auguste
    Nieuwland, Rienk
    van Leeuwen, Ton G.
    [J]. NANO LETTERS, 2014, 14 (11) : 6195 - 6201
  • [44] Coagulation activation anc microparticle-associated coagulant activity in cancer patients An exploratory prospective study
    van Doormaal, Frederiek F.
    Kleinjan, Ankie
    Berckmans, Rene J.
    Mackman, Nigel
    Manly, David
    Kamphuisen, Pieter W.
    Richel, Dick J.
    Buller, Harry R.
    Sturk, Auguste
    Nieuwland, Rienk
    [J]. THROMBOSIS AND HAEMOSTASIS, 2012, 108 (01) : 160 - 165
  • [45] NATURE AND SIGNIFICANCE OF PLATELET PRODUCTS IN HUMAN PLASMA
    WOLF, P
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1967, 13 (03) : 269 - +
  • [46] Elevated Plasma Endothelial Microparticles in Alzheimer's Disease
    Xue, Shouru
    Cai, Xiuyin
    Li, Wanjun
    Zhang, Zhengchun
    Dong, Wanli
    Hui, Guozhen
    [J]. DEMENTIA AND GERIATRIC COGNITIVE DISORDERS, 2012, 34 (3-4) : 174 - 180