Seismic performance of three-storey full-scale sub-standard reinforced concrete buildings

被引:7
作者
Comert, Mustafa [1 ]
Demir, Cem [1 ]
Ates, Ali Osman [1 ]
Orakcal, Kutay [2 ]
Ilki, Alper [1 ]
机构
[1] Istanbul Tech Univ, Fac Civil Engn, TR-34469 Istanbul, Turkey
[2] Bogazici Univ, Civil Engn Dept, TR-34342 Istanbul, Turkey
关键词
Building test; Field test; Column; Full scale; Lap-splice; Performance assessment; Reinforced concrete; Seismic behavior; PSEUDODYNAMIC TESTS; BEHAVIOR;
D O I
10.1007/s10518-016-0023-4
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Two three-story full-scale sub-standard reinforced concrete buildings were tested under self-weight and reversed cyclic lateral displacements to examine their behavior during earthquakes. While one of these buildings was a part of an actual existing building (TB1) built in the beginning of 1990's in Istanbul, the other was constructed by the authors as a representative building (TB2) that reflects the most common structural deficiencies of existing building stock in Turkey. Both buildings were constructed with plain bars, low strength concrete and inadequate lateral reinforcement. The differences between these buildings were axial load levels of first story columns, expected location of major structural damages (weak beam-strong column for TB1 and strong beam-weak column for TB2) and connection details of longitudinal bars in columns at the foundation-column interface (continuous for TB1 and lap-spliced with 180A degrees hooks for TB2). Both buildings were pushed and pulled at increasing displacement amplitudes up to near collapse well beyond the life safety performance level. While TB1 was damaged significantly at 1.5 % inter-story drift ratio, TB2 reached near collapse damage at 4.0 % inter-story drift ratio. In this paper, details and test results of these two sub-standard buildings are presented. In addition, the available nonlinear modeling techniques and performance predictions of the Turkish Seismic Design Code (Specification for the buildings to be constructed in disaster areas. Ministry of Public Works and Settlement, Ankara, 2007), ASCE 41-13 (Seismic rehabilitation of existing buildings, ASCE/SEI 41-13. ASCE, Reston, 2014) and Eurocode 8-3 (Eurocode 8: Design of structures for earthquake resistance. Part 3: Assessment and retrofitting of buildings. Comit, Europ,en de Normalisation, Bruxelles, 2005) are compared with the experimental results.
引用
收藏
页码:3293 / 3320
页数:28
相关论文
共 23 条
[1]  
[Anonymous], MOD COD 201 IN PRESS
[2]  
ASCE, 2014, 4113 ASCE SEI
[3]   Seismic behavior of a full-scale RC frame repaired using CFRP laminates [J].
Balsamo, A ;
Colombo, A ;
Manfredi, G ;
Negro, P ;
Prota, A .
ENGINEERING STRUCTURES, 2005, 27 (05) :769-780
[4]   Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragms [J].
Bournas, Dionysios A. ;
Negro, Paolo ;
Molina, Francisco J. .
ENGINEERING STRUCTURES, 2013, 57 :609-627
[5]  
CEN, 2005, CENTC250SC8N388B
[6]  
Computers and Structures Inc, 2011, 3D PERF BAS DES SOFT
[7]   Seismic upgrading of RC buildings by FRP: Full-scale tests of a real structure [J].
Della Corte, Gaetano ;
Barecchia, Enrico ;
Mazzolani, Federico M. .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2006, 18 (05) :659-669
[8]   Seismic Behavior of a full-scale RC structure retrofitted using GFRP laminates [J].
Di Ludovico, M. ;
Manfredi, G. ;
Mola, E. ;
Negro, P. ;
Prota, A. .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (05) :810-821
[9]   Structural models of critical regions in old-type r.c. frames with smooth rebars [J].
Fabbrocino, G ;
Verderame, GM ;
Manfredi, G ;
Cosenza, E .
ENGINEERING STRUCTURES, 2004, 26 (14) :2137-2148
[10]  
Federation Internationale du Beton (FIB), 2012, MOD COD 201 IN PRESS, V2