Hybrid Approach to Pulmonary Valve Replacement with Melody Prosthesis Following Pulmonary Banding

被引:14
作者
Abu Saleh, Walid K. [1 ]
Lin, Chun H. [1 ]
Breinholt, John P. [2 ]
Ramlawi, Basel [1 ]
机构
[1] Houston Methodist DeBakey Heart & Vasc Ctr, Houston, TX USA
[2] Univ Texas Hlth Sci Ctr Houston, Houston, TX 77030 USA
关键词
CLINICAL-TRIAL; IMPLANTATION;
D O I
10.1111/jocs.12695
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report the case of a 27-year-old Jehovah's Witness patient with severe pulmonary insufficiency and right ventricular dilatation 16 years after primary repair, who sought transcatheter therapy as a means to avoid surgery and the risk of blood product administration. A hybrid procedure involving pulmonary artery banding to a diameter amenable to fixation of a Melody valve (Medtronic Inc.) via trans-ventricular puncture was performed. doi: 10.1111/jocs.12695 (J Card Surg 2016;31:174-176)
引用
收藏
页码:174 / 176
页数:3
相关论文
共 5 条
[1]   Clinical Outcomes of Surgical Pulmonary Valve Replacement After Repair of Tetralogy of Fallot and Potential Prognostic Value of Preoperative Cardiopulmonary Exercise Testing [J].
Babu-Narayan, Sonya V. ;
Diller, Gerhard-Paul ;
Gheta, Radu R. ;
Bastin, Anthony J. ;
Karonis, Theodoros ;
Li, Wei ;
Pennell, Dudley J. ;
Uemura, Hideki ;
Sethia, Babulal ;
Gatzoulis, Michael A. ;
Shore, Darryl F. .
CIRCULATION, 2014, 129 (01) :18-27
[2]   The Medtronic Melody® Transcatheter Pulmonary Valve Implanted at 24-mm Diameter-It Works [J].
Cheatham, Sharon L. ;
Holzer, Ralf J. ;
Chisolm, Joanne L. ;
Cheatham, John P. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (05) :816-823
[3]   Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve for Conduit Failure in the Pulmonary Position Early Phase 1 Results From an International Multicenter Clinical Trial [J].
Kenny, Damien ;
Hijazi, Ziyad M. ;
Kar, Saibal ;
Rhodes, John ;
Mullen, Michael ;
Makkar, Raj ;
Shirali, Girish ;
Fogel, Mark ;
Fahey, John ;
Heitschmidt, Mary G. ;
Cain, Christopher .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) :2248-2256
[4]  
Suleiman T, 2015, FRONT SURG, V2, DOI [10.3389/tsurg.2C15.CCO22, 10.3389/fsurg.2015.00022]
[5]   Implantation of the Melody Transcatheter Pulmonary Valve in Patients With a Dysfunctional Right Ventricular Outflow Tract Conduit Early Results From the US Clinical Trial [J].
Zahn, Evan M. ;
Hellenbrand, William E. ;
Lock, James E. ;
McElhinney, Doff B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (18) :1722-1729