We have researched scintillation materials for neutron imaging detectors with a photon counting method. The aim of the research was to develop optimal scintillators, which have the well-balanced performances in detection efficiency, counting rate, n/gamma ratio, multi-counting rate, and neutron/gamma ratio for neutron scattering equipments using high-intensity pulsed neutron sources. The following scintillation materials were researched: ZnS-series phosphors with neutron converters, short-life-time phosphors with neutron converters, short-life-time phosphors containing B-10, glass scintillators containing B-10 or Li-6, Li-6-loaded plastic scintillators and organic phosphors containing B-10. The detection-characteristics of these scintillators were discussed, mainly for their detection efficiency. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:274 / 279
页数:6
相关论文
共 5 条
[1]   Position sensitive scintillation neutron detectors using a crossed-fiber optic readout array [J].
Hutchinson, DP ;
Richards, RK ;
Holcomb, DE ;
Ramsey, JA .
PENETRATING RADIATION SYSTEMS AND APPLICATIONS, 1999, 3769 :88-91
[2]  
*ISIS FAC, RALTR2003050
[3]   High-counting-rate and high-position-resolution neutron imaging detectors using short-lifetime phosphors with crossed-fiber readout [J].
Katagiri, M ;
Sakasai, K ;
Matsubayashi, M ;
Takahashi, H ;
Nakazawa, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2) :374-378
[4]   High-position-resolution scintillation neutron-imaging detector by crossed-fiber readout with novel centroid-finding method [J].
Katagiri, M ;
Toh, K ;
Sakasai, K ;
Matsubayashi, M ;
Birumachi, A ;
Takahashi, H ;
Nakazawa, M .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1) :S1604-S1606
[5]   Inorganic-scintillator development [J].
van Eijk, CWE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (01) :1-14