Paper spray mass spectrometry applied in the monitoring of a chemical system in dynamic chemical equilibrium: the redox process of methylene blue

被引:9
作者
Almeida de Paula, Camila Cristina [1 ]
Valadares, Alberto [1 ]
Jurisch, Marina [1 ]
Piccin, Evandro [1 ]
Augusti, Rodinei [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Quim, BR-31270901 Belo Horizonte, MG, Brazil
关键词
IONIZATION; RESIDUES; COCAINE;
D O I
10.1002/rcm.7546
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleThe monitoring of chemical systems in dynamic equilibrium is not an easy task. This is due to the high rate at which the system returns to equilibrium after being perturbed, which hampers the possibility of following the aftereffects of the disturbance. In this context, it is necessary to use a fast analytical technique that requires no (or minimal) sample preparation, and which is capable of monitoring the species constituting the system in equilibrium. Paper spray ionization mass spectrometry (PS-MS), a recently introduced ambient ionization technique, has such characteristics and hence was chosen for monitoring a model system: the redox process of methylene blue. MethodsThe model system evaluated herein was composed of three cationic species of methylene blue (MB), which coexist in a dynamic redox system: (1) [MB](+) of m/z 284 (cationic MB); (2) [MB + H + e](+center dot) of m/z 285 (the protonated form of a transient species resulting from the reduction of [MB](+)); (3) [MB + 2H + 2e](+) or [leuco-MB + H](+) of m/z 286 (the protonated leuco form of MB). Aliquots of a MB solution were collected before and after the addition of a reducing agent (metallic zinc) and directly analyzed by PS-MS for identification of the predominant cationic species at different conditions. ResultsThe mass spectra revealed that before the addition of the reducing agent the ion of m/z 284 (cationic MB) is the unique species. Upon the addition of the reducing agent and acid, however, the solution continuously undergo discoloration while reduced species derived directly from cationic MB (m/z 285 and 286) are detected in the mass spectra with increasing intensities. Fragmentation patterns obtained for each ionic species, i.e. [MB](+), [MB + H + e](+center dot) and [leuco-MB + H](+), shown to be consistent with the proposed structures. ConclusionsThe PS-MS technique proved to be suitable for an in situ and 'near' real-time analysis of the dynamic equilibrium involving the redox of MB in aqueous medium. The data clearly demonstrated how the redox equilibrium shifts depending on the disturbance caused to the system. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:1176 / 1180
页数:5
相关论文
共 23 条
[1]  
de Paula CCA, 2015, ANAL METHODS-UK, V7, P9145, DOI [10.1039/C5AY02263K, 10.1039/c5ay02263k]
[2]   Chemical fingerprint analysis for quality assessment and control of Bansha herbal tea using paper spray mass spectrometry [J].
Deng, Jiewei ;
Yang, Yunyun .
ANALYTICA CHIMICA ACTA, 2013, 785 :82-90
[3]   Spray mechanism in paper spray ionization [J].
Espy, Ryan D. ;
Muliadi, Ariel R. ;
Ouyang, Zheng ;
Cooks, R. Graham .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 325 :167-171
[4]   DNA interactions with a Methylene Blue redox indicator depend on the DNA length and are sequence specific [J].
Farjami, Elaheh ;
Clima, Lilia ;
Gothelf, Kurt V. ;
Ferapontova, Elena E. .
ANALYST, 2010, 135 (06) :1443-1448
[5]   Forensic analysis of ballpoint pen inks using paper spray mass spectrometry [J].
Ferreira, Priscila da Silva ;
de Abreu e Silva, Debora Fernandes ;
Augusti, Rodinei ;
Piccin, Evandro .
ANALYST, 2015, 140 (03) :811-819
[6]   Coffee origin discrimination by paper spray mass spectrometry and direct coffee spray analysis [J].
Garrett, Rafael ;
Rezende, Claudia M. ;
Ifa, Demian R. .
ANALYTICAL METHODS, 2013, 5 (21) :5944-5948
[7]   In situ analysis of corrosion inhibitors using a portable mass spectrometer with paper spray ionization [J].
Jjunju, Fred. P. M. ;
Li, Anyin ;
Badu-Tawiah, Abraham ;
Wei, Pu ;
Li, Linfan ;
Ouyang, Zheng ;
Roqan, Iman S. ;
Cooks, R. Graham .
ANALYST, 2013, 138 (13) :3740-3748
[8]   Direct analysis of 4-methylimidazole in foods using paper spray mass spectrometry [J].
Li, Anyin ;
Wei, Pu ;
Hsu, Hsu-Chen ;
Cooks, R. Graham .
ANALYST, 2013, 138 (16) :4624-4630
[9]   Rapid, in situ detection of cocaine residues based on paper spray ionization coupled with ion mobility spectrometry [J].
Li, Ming ;
Zhang, Jingjing ;
Jiang, Jie ;
Zhang, Jing ;
Gao, Jing ;
Qiao, Xiaolin .
ANALYST, 2014, 139 (07) :1687-1691
[10]   Development, Characterization, and Application of Paper Spray Ionization [J].
Liu, Jiangjiang ;
Wang, He ;
Manicke, Nicholas E. ;
Lin, Jin-Ming ;
Cooks, R. Graham ;
Ouyang, Zheng .
ANALYTICAL CHEMISTRY, 2010, 82 (06) :2463-2471