The efficient operation of a solar cooling system strongly depends on the chiller behavior under part load conditions, since driving energy and cooling load are never constant. For this reason, the performance of a single stage, hot water driven 30 kW H(2)O/LiBr-absorption chiller employed in a solar cooling system with a field of 350 m(2) evacuated tube collector has been analyzed under part load conditions with both simulations and experiments. A simulation model has been developed for the whole absorption chiller (Type Yazaki WFC-10), where all internal mass and energy balances are solved. The connection to the external heat reservoirs of hot, chilled, and cooling water is done by lumped and distributed UA values for the main heat exchangers. In addition to an analytical evaporator model-which is described in detail-experimental correlations for UA values have been used for the condenser, generator, and solution heat exchanger. For the absorber, a basic model based on the Nusselt theory has been employed. The evaporator model was developed, taking into account the distribution of refrigerant on the tube bundle, as well as the change in operation from a partially dry to an overflowing evaporator. A linear model is derived to calculate the wetted area. The influence of these effects on cooling capacity and coefficient of performance (COP) is calculated for three different combinations of hot and cooling water temperature. The comparison to experimental data shows a good agreement in the various operational modes of the evaporator. The model is able to predict the transition from partially dry to an overflowing evaporator quite well. The present deviations in the domain with high refrigerant overflow can be attributed to the simple absorber model and the linear wetted area model. Nevertheless, the results of this investigation can be used to improve control strategies for new and existing solar cooling systems.
引用
收藏
页码:0110161 / 0110168
页数:8
相关论文
共 14 条
[1]  
ALBERS J, 2003, P 21 INT C REFR IIR
[2]  
Albers J., 2005, P INT SORPT HEAT PUM
[3]  
[Anonymous], 1970, ACADEMIC
[4]   Experimental evaluation of the performances of a H2O-LiBr absorption refrigerator under different service conditions [J].
Asdrubali, F ;
Grignaffini, S .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (04) :489-497
[5]   Validation of a model for the absorption process of H2O(vap) by a LiBr(aq) in a horizontal tube bundle, using a multi-factorial analysis [J].
Francés, VMS ;
Ojer, JMP .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (17) :3299-3312
[6]  
Grossman G., 1985, ASHRAE Transactions, V91, P1808
[7]  
Hellmann H.M., 1998, P EUROTHERM SEMINAR, V59, P219
[8]  
HU X, 1996, ASME, V118, P616, DOI DOI 10.1115/1.2822676
[9]   The effect of micro-scale surface treatment on heat and mass transfer performance for a falling film H2O/LiBr absorber [J].
Kim, JK ;
Park, CW ;
Kang, YT .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (05) :575-585
[10]  
KLEIN SA, 1990, EES ENG EQUATION SOL