Accuracy of dual-source computed tomography coronary angiography: evaluation with a standardised protocol for cardiac surgeons

被引:9
|
作者
Plass, Andre [1 ]
Azemaj, Naim [1 ]
Scheffel, Hans [2 ]
Desbiolles, Lotus [2 ]
Alkadhi, Hatem [2 ]
Genoni, Michele [1 ]
Falk, Volkmar [1 ]
Grunenfelder, Jurg [1 ]
机构
[1] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
关键词
Coronary artery imaging; Dual-source computed tomography; Cardiac surgery; MULTISLICE SPIRAL CT; ARTERY-DISEASE; TEMPORAL RESOLUTION; DIAGNOSTIC-ACCURACY; 1ST EXPERIENCE; HEART; RECONSTRUCTION; QUANTIFICATION; CARDIOLOGY;
D O I
10.1016/j.ejcts.2009.06.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study assesses the accuracy of the new dual-source computed tomography (DSCT) for detection of coronary artery disease (CAD) compared with invasive coronary angiography (ICA) with a specifically designed data presentation protocol for cardiac surgeons. Methods: Forty patients (30 males/10 females) underwent ICA and DSCT. Best-quality images were prepared by radiologists. Evaluation of 12 segments of significant coronary stenosis was done by two cardiac surgeons with a data presentation protocol including different coronary views in two-/three-dimensional (2D/3D) images. No beta-blockers were administered prior to DSCT. Results: ICA revealed CAD in 21 patients and valvular disease but no CAD in 19 patients. In DSCT, 20/21 patients were diagnosed with CAD (at least one significant stenosis per patient). In 11/21 patients, all 12 segments were assessed correctly; in 7/21 patients one segment and in 3/21 patients two segments were evaluated incorrectly. Of all 21 patients with CAD, 239/252 segments (95%) were correctly evaluated. In 18/19 patients without CAD, DSCT correctly ruled-out the ICA results in 226/228 segments (99%). In total, 465/480 segments were correctly assessed (97%). Of 480 segments, only six were considered not assessable. DSCT assessments of the segments showed a sensitivity of 91%, specificity of 99%, a positive predictive value of 92% and a negative predictive value of 99%. Conclusions: The accuracy of DSCT coronary angiography especially for exclusion of CAD is promising. The introduced data presentation protocol allows for the independent evaluation by cardiac surgeons after pre-arrangement from the radiologists. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1011 / 1017
页数:7
相关论文
共 50 条
  • [31] Diagnostic accuracy of dual-source CT angiography and coronary risk stratification
    Yang, Xia
    Gai, Lu-yue
    Li, Ping
    Chen, Yun-dai
    Li, Tao
    Yang, Li
    VASCULAR HEALTH AND RISK MANAGEMENT, 2010, 6 : 935 - 941
  • [32] Multiphase Evaluation of Myocardial Bridging with Dual-Source Computed Tomography
    Zhang, Long Jiang
    Yang, Gui Fen
    Zhou, Chang Sheng
    Huang, Wei
    Lu, Guang Ming
    Shiroishi, M. S.
    ACTA RADIOLOGICA, 2009, 50 (07) : 775 - 780
  • [33] Dual-Source Computed Tomography for Chronic Total Occlusion of Coronary Arteries
    Singh, Sandeep
    Singh, Navreet
    Gulati, Gurpreet S.
    Ramakrishnan, Sivasubramanian
    Kumar, Guresh
    Sharma, Sanjiv
    Bahl, Vinay K.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (04) : E117 - E125
  • [34] Dual-source cardiac computed tomography: image quality and dose considerations
    Achenbach, Stephan
    Anders, Katharina
    Kalender, Willi A.
    EUROPEAN RADIOLOGY, 2008, 18 (06) : 1188 - 1198
  • [35] Coronary vasodilation by the use of sublingual nitroglycerin using 64-slice dual-source coronary computed tomography angiography
    Okada, Munemasa
    Nakashima, Yoshiteru
    Nomura, Takafumi
    Miura, Toshiro
    Nao, Tomoko
    Yoshimura, Masayuki
    Sano, Yuichi
    Matsunaga, Naofumi
    JOURNAL OF CARDIOLOGY, 2015, 65 (3-4) : 230 - 236
  • [36] Dual-source computed tomography for assessing cardiac function -: A phantom study
    Mahnken, Andreas H.
    Bruder, Herbert
    Suess, Christoph
    Muelenbruch, Georg
    Bruners, Philipp
    Hohl, Christian
    Guenther, Ro F. W.
    Wildberger, Joachim E.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (07) : 491 - 498
  • [37] The reliability of automatic measurement of left ventricular function with dual-source computed tomography datasets
    de Jonge, G. J.
    van Ooijen, P. M. A.
    van der Vleuten, P. A.
    Lubbers, D. D.
    Kasemier, J. H.
    de Bock, G. H.
    Oudkerk, M.
    EUROPEAN RADIOLOGY, 2009, 19 (12) : 2919 - 2930
  • [38] Dual-source cardiac computed tomography: image quality and dose considerations
    Stephan Achenbach
    Katharina Anders
    Willi A. Kalender
    European Radiology, 2008, 18 : 1188 - 1198
  • [39] Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography
    Karaarslan, Ercan
    Ulus, Sila
    Bavbek, Cengiz
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 407 - 414
  • [40] Adenosine triphosphate stress dual-source computed tomography to identify myocardial ischemia: comparison with invasive coronary angiography
    Kido, Teruhito
    Watanabe, Kouki
    Saeki, Hideyuki
    Shigemi, Susumu
    Matsuda, Takeshi
    Yamamoto, Masaya
    Kurata, Akira
    Kanza, Rene Epunza
    Itoh, Toshihide
    Mochizuki, Teruhito
    SPRINGERPLUS, 2014, 3 : 1 - 6