Accuracy of dual-source computed tomography coronary angiography: evaluation with a standardised protocol for cardiac surgeons

被引:9
作者
Plass, Andre [1 ]
Azemaj, Naim [1 ]
Scheffel, Hans [2 ]
Desbiolles, Lotus [2 ]
Alkadhi, Hatem [2 ]
Genoni, Michele [1 ]
Falk, Volkmar [1 ]
Grunenfelder, Jurg [1 ]
机构
[1] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
关键词
Coronary artery imaging; Dual-source computed tomography; Cardiac surgery; MULTISLICE SPIRAL CT; ARTERY-DISEASE; TEMPORAL RESOLUTION; DIAGNOSTIC-ACCURACY; 1ST EXPERIENCE; HEART; RECONSTRUCTION; QUANTIFICATION; CARDIOLOGY;
D O I
10.1016/j.ejcts.2009.06.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study assesses the accuracy of the new dual-source computed tomography (DSCT) for detection of coronary artery disease (CAD) compared with invasive coronary angiography (ICA) with a specifically designed data presentation protocol for cardiac surgeons. Methods: Forty patients (30 males/10 females) underwent ICA and DSCT. Best-quality images were prepared by radiologists. Evaluation of 12 segments of significant coronary stenosis was done by two cardiac surgeons with a data presentation protocol including different coronary views in two-/three-dimensional (2D/3D) images. No beta-blockers were administered prior to DSCT. Results: ICA revealed CAD in 21 patients and valvular disease but no CAD in 19 patients. In DSCT, 20/21 patients were diagnosed with CAD (at least one significant stenosis per patient). In 11/21 patients, all 12 segments were assessed correctly; in 7/21 patients one segment and in 3/21 patients two segments were evaluated incorrectly. Of all 21 patients with CAD, 239/252 segments (95%) were correctly evaluated. In 18/19 patients without CAD, DSCT correctly ruled-out the ICA results in 226/228 segments (99%). In total, 465/480 segments were correctly assessed (97%). Of 480 segments, only six were considered not assessable. DSCT assessments of the segments showed a sensitivity of 91%, specificity of 99%, a positive predictive value of 92% and a negative predictive value of 99%. Conclusions: The accuracy of DSCT coronary angiography especially for exclusion of CAD is promising. The introduced data presentation protocol allows for the independent evaluation by cardiac surgeons after pre-arrangement from the radiologists. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1011 / 1017
页数:7
相关论文
共 50 条
  • [21] Preoperative evaluation of coronary artery fistula using dual-source computed tomography
    Jiang, Yaowen
    Liu, Peng
    Cao, Yu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 234 : 117 - 117
  • [22] Preoperative evaluation of coronary artery fistula using dual-source computed tomography
    Shi, Ke
    Gao, Hong-ling
    Yang, Zhi-gang
    Zhang, Qin
    Liu, Xi
    Guo, Ying-kun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 228 : 80 - 85
  • [23] Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography
    Kirchhoff, S.
    Herzog, P.
    Johnson, T.
    Boehm, H.
    Nikolaou, K.
    Reiser, M. F.
    Becker, C. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) : E182 - E186
  • [24] Image Quality and Dose Reduction by Dual Source Computed Tomography Coronary Angiography: Protocol Comparison
    Forte, Ernesto
    Monti, Serena
    Parente, Chiara Anna
    Beyer, Lukas
    De Rosa, Roberto
    Infante, Teresa
    Cavaliere, Carlo
    Cademartiri, Filippo
    Salvatore, Marco
    Stroszczynski, Christian
    Tedeschi, Carlo
    DOSE-RESPONSE, 2018, 16 (04):
  • [25] Cardiac dual-source computed tomography - Effect of body mass index on image quality and diagnostic accuracy
    Brodoefel, Harald
    Tsiflikas, Ilias
    Burgstahler, Christof
    Reimann, Anja
    Thomas, Christoph
    Schroeder, Stephen
    Kopp, Andreas F.
    Claussen, Claus D.
    Heuschmid, Martin
    INVESTIGATIVE RADIOLOGY, 2008, 43 (10) : 712 - 718
  • [26] Visualization of anomalous coronary arteries on dual-source computed tomography
    G. J. de Jonge
    P. M. A. van Ooijen
    L. H. Piers
    R. Dikkers
    R. A. Tio
    T. P. Willems
    A. F. M. van den Heuvel
    F. Zijlstra
    M. Oudkerk
    European Radiology, 2008, 18 : 2425 - 2432
  • [27] Visualization of anomalous coronary arteries on dual-source computed tomography
    de Jonge, G. J.
    van Ooijen, P. M. A.
    Piers, L. H.
    Dikkers, R.
    Tio, R. A.
    Willems, T. P.
    van den Heuvel, A. F. M.
    Zijlstra, F.
    Oudkerk, M.
    EUROPEAN RADIOLOGY, 2008, 18 (11) : 2425 - 2432
  • [28] Predictors of disagreement between prospectively ECG-triggered dual-source coronary computed tomography angiography and conventional coronary angiography
    Muzzarelli, Stefano
    Suerder, Daniel
    Murzilli, Romina
    Donato, Lucia
    Pedrazzini, Giovanni
    Pasotti, Elena
    Moccetti, Tiziano
    Klersy, Catherine
    Faletra, Francesco Fulvio
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (06) : 1138 - 1146
  • [29] Direct costs and cost-effectiveness of dual-source computed tomography and invasive coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
    Dorenkamp, Marc
    Bonaventura, Klaus
    Sohns, Christian
    Becker, Christoph R.
    Leber, Alexander W.
    HEART, 2012, 98 (06) : 460 - 467
  • [30] Noninvasive Assessment of Coronary In-Stent Restenosis by Dual-Source Computed Tomography
    Pflederer, Tobias
    Marwan, Mohamed
    Renz, Alexandra
    Bachmann, Sven
    Ropers, Dieter
    Kuettner, Axel
    Anders, Katharina
    Bamberg, Fabian
    Daniel, Werner G.
    Achenbach, Stephan
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (06) : 812 - 817