A review of lung cancer screening and the role of computer-aided detection

被引:91
作者
Al Mohammad, B. [1 ]
Brennan, P. C. [1 ]
Mello-Thoms, C. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, 75 East St, Lidcombe, NSW 2141, Australia
关键词
PULMONARY NODULES; AUTOMATED DETECTION; CHEST CT; DETECTION CAD; RADIOLOGIST PERFORMANCE; DIAGNOSTIC ERRORS; DETECTION SYSTEM; HELICAL CT; SPIRAL CT; DOSE CT;
D O I
10.1016/j.crad.2017.01.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Lung cancer is the leading cause of cancer-related death worldwide; however, early diagnosis of lung cancer leads to higher survival rates. The National Lung Screening Trial (NLST) demonstrated that scanning with low-dose computed tomography (LDCT) led to a 20% reduction in mortality rate in a high-risk population. This paper covers new developments in screening eligibility criteria and the possible benefits and the harm of screening with CT. To make the screening process more feasible and help reduce the rate of missed lung nodules, computer-aided detection (CAD) has been introduced to assist radiologists in lung nodule detection. The aim of this paper is to review how CAD works, its performance in lung nodule detection, and the factors that influence its performance. This paper also aims to investigate the effect of different types of CAD on CT in lung nodule detection and the effect of CAD on radiologists' decision outcomes. (C) 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:433 / 442
页数:10
相关论文
共 95 条
[41]  
Henschke CI, 2006, NEW ENGL J MED, V355, P1763, DOI 10.1056/NEJMoa060476
[42]   A Randomized Study of Lung Cancer Screening with Spiral Computed Tomography Three-year Results from the DANTE Trial [J].
Infante, Maurizio ;
Cavuto, Silvio ;
Lutman, Fabio Romano ;
Brambilla, Giorgio ;
Chiesa, Giuseppe ;
Ceresoli, Giovanni ;
Passera, Eliseo ;
Angeli, Enzo ;
Chiarenza, Maurizio ;
Aranzulla, Giuseppe ;
Cariboni, Umberto ;
Errico, Valentina ;
Inzirillo, Francesco ;
Bottoni, Edoardo ;
Voulaz, Emanuele ;
Alloisio, Marco ;
Destro, Anna ;
Roncalli, Massimo ;
Santoro, Armando ;
Ravasi, Gianluigi .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 180 (05) :445-453
[43]   A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT [J].
Iwasawa, Tae ;
Matsumoto, Sumiaki ;
Aoki, Takatoshi ;
Okada, Fumito ;
Nishimura, Yoshihiro ;
Yamagata, Hitoshi ;
Ohno, Yoshiharu .
JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) :76-83
[44]   Healthcare costs and resource utilization of asthma in Germany: a claims data analysis [J].
Jacob, Christian ;
Bechtel, Benno ;
Engel, Susanne ;
Kardos, Peter ;
Linder, Roland ;
Braun, Sebastian ;
Greiner, Wolfgang .
EUROPEAN JOURNAL OF HEALTH ECONOMICS, 2016, 17 (02) :195-201
[45]   Computer-Aided Nodule Detection and Volumetry to Reduce Variability Between Radiologists in the Interpretation of Lung Nodules at Low-Dose Screening Computed Tomography [J].
Jeon, Kyung Nyeo ;
Goo, Jin Mo ;
Lee, Chang Hyun ;
Lee, Youkyung ;
Choo, Ji Yung ;
Lee, Nyoung Keun ;
Shim, Mi-Suk ;
Lee, In Sun ;
Kim, Kwang Gi ;
Gierada, David S. ;
Bae, Kyongtae T. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (08) :457-461
[46]   Detection failures in spiral CT screening for lung cancer: Analysis of CT findings [J].
Kakinuma, R ;
Ohmatsu, H ;
Kaneko, M ;
Eguchi, K ;
Naruke, T ;
Nagai, K ;
Nishiwaki, Y ;
Suzuki, A ;
Moriyama, N .
RADIOLOGY, 1999, 212 (01) :61-66
[47]   Automated detection of pulmonary nodules on CT images: Effect of section thickness and reconstruction interval - Initial results [J].
Kim, JS ;
Kim, JH ;
Cho, GS ;
Bae, KT .
RADIOLOGY, 2005, 236 (01) :295-299
[48]   Chest CT: Automated nodule detection and assessment of change over time - Preliminary experience [J].
Ko, JP ;
Betke, M .
RADIOLOGY, 2001, 218 (01) :267-273
[49]  
KUBIK A, 1986, CANCER-AM CANCER SOC, V57, P2427, DOI 10.1002/1097-0142(19860615)57:12<2427::AID-CNCR2820571230>3.0.CO
[50]  
2-M