Quantifying Step Count and Oxygen Consumption with Portable Technology during the 2-Min Walk Test in People with Lower Limb Amputation

被引:7
作者
Smith, John D. [1 ]
Guerra, Gary [2 ]
机构
[1] Texas A&M Univ, Dept Counseling Hlth & Kinesiol, 1 Univ Way, San Antonio, TX 78224 USA
[2] Mahidol Univ, Sirindhorn Sch Prosthet & Orthot, Siriraj Hosp, Fac Med, Bangkok 10700, Thailand
关键词
lower-limb prosthesis; wearable activity monitors; metabolic cost; 2MWT; oxygen consumption; actigraphy; accelerometer; PERIPHERAL VASCULAR-DISEASE; ENERGY-EXPENDITURE; PROSTHETIC LINERS; ACTIVITY MONITORS; UNITED-STATES; CAPACITY; AMPUTEES; REHABILITATION; PERFORMANCE; AMBULATION;
D O I
10.3390/s21062080
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Step counts and oxygen consumption have yet to be reported during the 2-min walk test (2MWT) test in persons with lower-limb amputations (LLA). The purpose of this study was to determine step counts and oxygen consumption during the 2MWT in LLA. Thirty-five men and women walked for two minutes as quickly as possible while wearing activity monitors (ActiGraph Link on the wrist (LW) and ankle (LA), Garmin vivofit(R)3 on the wrist (VW) and ankle (VA), and a modus StepWatch on the ankle (SA), and a portable oxygen analyzer. The StepWatch on the ankle (SA) and the vivofit3 on the wrist (VW) had the least error and best accuracy of the activity monitors studied. While there were no significant differences in distance walked, oxygen consumption (VO2) or heart rate (HR) between sexes or level of amputation (p > 0.05), females took significantly more steps than males (p = 0.034), and those with unilateral transfemoral amputations took significantly fewer steps than those with unilateral transtibial amputations (p = 0.023). The VW and SA provided the most accurate step counts among the activity monitors and were not significantly different than hand counts. Oxygen consumption for all participants during the 2MWT was 8.9 +/- 2.9 mL/kg/min, which is lower than moderate-intensity activity. While some may argue that steady-state activity has not yet been reached in the 2MWT, it may also be possible participants are not walking as fast as they can, thereby misclassifying their performance to a lower standard.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 7 条
  • [1] The Utility of the 2-Minute Walk Test as a Measure of Mobility in People With Lower Limb Amputation
    Gaunaurd, Ignacio
    Kristal, Anat
    Horn, Amber
    Krueger, Chloe
    Muro, Olivia
    Rosenberg, Alyssa
    Gruben, Kurt
    Kirk-Sanchez, Neva
    Pasquina, Paul
    Gailey, Robert
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2020, 101 (07): : 1183 - 1189
  • [2] The use of the 6-min walk test as a proxy for the assessment of energy expenditure during gait in individuals with lower-limb amputation
    Kark, Lauren
    McIntosh, Andrew S.
    Simmons, Anne
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2011, 34 (03) : 227 - 234
  • [3] The 2-minute walk test as a measure of functional improvement in persons with lower limb amputation
    Brooks, D
    Parsons, J
    Hunter, JP
    Devlin, M
    Walker, J
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (10): : 1478 - 1483
  • [4] Validation of Body-Worn Sensors for Gait Analysis During a 2-min Walk Test in Children
    Shieh, Vincent
    Zampieri, Cris
    Sansare, Ashwini
    Collins, John
    Bulea, Thomas C.
    Jain, Minal
    JOURNAL FOR THE MEASUREMENT OF PHYSICAL BEHAVIOUR, 2022, 5 (02) : 111 - 119
  • [5] Temporal-Spatial Values During a 180° Step Turn in People with Unilateral Lower Limb Amputation
    Clemens, Sheila M.
    Klute, Glenn K.
    Kirk-Sanchez, Neva J.
    Raya, Michele A.
    Kim, Kyoung Jae
    Gaunaurd, Ignacio A.
    Gailey, Robert S.
    GAIT & POSTURE, 2018, 63 : 276 - 281
  • [6] Clinical Walking Tests and Gait Pattern Characterization During 6-Minute Walk Test Using Inertial Sensors: Follow-Up in Individuals With Lower Limb Amputation
    Younesian, Hananeh
    Legrand, Thomas
    Miramand, Ludovic
    Beausoleil, Sarah
    Turcot, Katia
    JOURNAL OF APPLIED BIOMECHANICS, 2021, 37 (05) : 440 - 449
  • [7] LATE-BREAKING ABSTRACT: Maximum oxygen uptake (maxVO2) during a 6-minute step test (6-MST) in healthy people: Validation of a low cost exercise test
    Chrisoherakis, Georgios
    Karabinos, Ilias
    Papanikolaou, Nikolaos
    Papagoras, Charalambos
    Kostaki, Panagiota
    Papadopoulos, Anastasios
    Zachariadis, Emmanouil
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46