Determination of europium isotope ratios in natural waters by MC-ICP-MS

被引:0
作者
Arantes de Carvalho, Gabriel Gustinelli [1 ,2 ]
Oliveira, Pedro Vitoriano [2 ]
Yang, Lu [1 ]
机构
[1] Natl Res Council Canada, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
[2] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, Av Prof Lineu Prestes 748, BR-05513970 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
RARE-EARTH-ELEMENTS; MASS-SPECTROMETRY; ACCURATE DETERMINATION; SILICATE ROCKS; CHROMATOGRAPHY; SAMPLES; EXTRACTION; PRECISE; SEPARATION; ND-143/ND-144;
D O I
10.1039/c7ja00020k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical protocol for the accurate and precise determination of the europium isotope ratio in low level natural waters is presented for the first time by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Parameters affecting the separation of Eu from the matrix by employing a single-step column separation with di(2-ethylhexyl) orthophosphoric acid (HDEHP) resin were investigated in detail. Matrix elements (e.g., alkali, alkali-earth and transition metals) were efficiently removed and Eu was quantitatively separated from other rare earth elements (REEs) by sequential elution using gradient HCl concentrations (from 0.25 to 0.75 mol L-1). Fractionation of Eu isotopes in the column was not observed, since quantitative europium recovery (101.2 +/- 0.5% mean and 1 SD, n = 3) was obtained (data based on 150 mL SLRS-6 river water CRM test portions spiked with 1.0 ng mL(-1) Eu standard solution). A combined standard-sample bracketing with internal normalization method was employed for the mass bias correction, wherein Gd was added to both the sample and standard as an internal standard. The developed method was validated by processing 0.02 ng mL(-1) Eu spiked river water CRM SLRS-6 (wherein Eu was removed first by using the above-mentioned column separation method) using the proposed method, and satisfying results (delta Eu-151/153 value of 0.01 +/- 0.02 parts per thousand; 1 SD) relative to Eu standard solution were obtained. No significant differences were found in the delta Eu-151/153 values in river water SLRS-6, drinking water AQUA-1 and collected groundwater samples from Brazil, which ranged from -0.07 +/- 0.02 to 0.12 +/- 0.24 (mean +/- 1 SD, n = 5).
引用
收藏
页码:987 / 995
页数:9
相关论文
共 50 条
  • [21] Uranium Isotope Ratios of Twenty-nine Geological Rock Reference Materials Measured by MC-ICP-MS
    Wang, Xuefeng
    Wang, Xiangli
    Wang, Lisheng
    Wu, Shitou
    Xue, Dingshuai
    Duan, Wuhui
    Ma, Zhibang
    Xiao, Jule
    Li, Xianhua
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (04) : 945 - 955
  • [22] Accurate and precise determination of stable Cr isotope compositions in carbonates by double spike MC-ICP-MS
    Bonnand, Pierre
    Parkinson, Ian J.
    James, Rachael H.
    Karjalainen, Anne-Mari
    Fehr, Manuela A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 528 - 535
  • [23] Calcium isotope measurements using a collision cell (CC)-MC-ICP-MS
    Dai, Wei
    Moynier, Frederic
    Paquet, Marine
    Moureau, Julien
    Debret, Baptiste
    Siebert, Julien
    Gerard, Yvan
    Zhao, Ye
    CHEMICAL GEOLOGY, 2022, 590
  • [24] Precise determination of lithium isotope ratios at the sub-nanogram level by QQQ-ICP-MS: application to natural waters and carbonates
    Juzer, Shaikh
    Tanwar, Neha
    Misra, Sambuddha
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (07) : 1541 - 1553
  • [25] Solution and laser ablation MC-ICP-MS lead isotope analysis of gold
    Standish, Christopher
    Dhuime, Bruno
    Chapman, Robert
    Coath, Christopher
    Hawkesworth, Chris
    Pike, Alistair
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (02) : 217 - 225
  • [26] Gd matrix effects on Eu isotope fractionation using MC-ICP-MS: Optimizing europium isotope ratio measurements in geological rock samples
    Lee, Seung-Gu
    Tanaka, Tsuyoshi
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 469
  • [27] Precise determination of lithium isotopes in seawater using MC-ICP-MS
    Choi, Min Seok
    Shin, Hyung Seon
    Kil, Young Woo
    MICROCHEMICAL JOURNAL, 2010, 95 (02) : 274 - 278
  • [28] Precise Determination of Stable Strontium Isotopic Compositions by MC-ICP-MS
    Xu, Juan
    Yang, Shouye
    Yang, Yueheng
    Liu, Yongsheng
    Xie, Xiaolei
    ATOMIC SPECTROSCOPY, 2020, 41 (02) : 64 - 73
  • [29] A simplified instrumental protocol for trace Nd and Hf isotope measurements (<10 ng) using a MC-ICP-MS and an Apex Omega de-solvating system
    Zhou, Ting
    Qi, Liang
    Liu, Sheng-hua
    Zhou, Bo
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (11) : 2694 - 2702
  • [30] Accurate determination of Cu isotope compositions in Cu-bearing minerals using microdrilling and MC-ICP-MS
    Lv, Nan
    Bao, Zhian
    Chen, Lu
    Chen, Kaiyun
    Zhang, Yan
    Yuan, Honglin
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 457