<bold>Wireless Real-Time Gamma Radiation Dosimetry System Using MgO and CeO2 Thick Film Capacitors</bold>

被引:1
作者
Arshak, K. [1 ]
Kaneswaran, K. [1 ]
Korostynska, O. [1 ]
Morris, D. [2 ]
Arshak, A. [2 ]
机构
[1] Univ Limerick, Dept Elect & Comp Engn, Limerick, Ireland
[2] Univ Limerick, Dept Phys, Limerick, Ireland
来源
PROCEEDINGS OF THE 2006 IEEE SENSORS APPLICATIONS SYMPOSIUM | 2006年
关键词
gamma-radiation; thick film; real-time dosimetry; circuit; interdigitated capacitor; assembly code; capacitance to digital converter;
D O I
10.1109/SAS.2006.1634237
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In aggressive industrial processes, power plants and radioactive waste storage places it is important to monitor the level of radiation. To minimise personnel exposure a wireless system is presented, where thick film MgO and CeO2 capacitors with Ag interdigitated electrodes were used as prototype radiation sensors. MgO and CeO2 thick films were monitored during radiation exposure using a capacitance to digital converter system. A monotonic increase in the values of capacitance from 1.493 pF to 1.537 pF was recorded for MgO as a result of 32.55 mGy gamma-dose of A(137) CS gamma-source. Counterpart CeO2 films were shown to be less susceptible to radiation. Moreover, the response of MgO sensor was monotonic over the whole range.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 10 条
[1]   Thin and thick films of metal oxides and metal phthalocyanines as gamma radiation dosimeters [J].
Arshak, K ;
Arshak, A ;
Zleetni, S ;
Korostynska, O .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2250-2255
[2]   γ-radiation sensing properties of cerium oxide based thick film structures [J].
Arshak, K ;
Korostynska, O .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 115 (2-3) :196-201
[3]  
HOLMESSIEDLE AG, 1993, HDB RADIAT EFFECTS
[4]   Analytical evaluation of the interdigital electrodes capacitance for a multi-layered structure [J].
Igreja, R ;
Dias, CJ .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 112 (2-3) :291-301
[5]  
Kaczmarek SM, 1999, CRYST RES TECHNOL, V34, P719, DOI 10.1002/(SICI)1521-4079(199906)34:5/6<719::AID-CRAT719>3.0.CO
[6]  
2-T
[7]   Interdigital sensors and transducers [J].
Mamishev, AV ;
Sundara-Rajan, K ;
Yang, F ;
Du, YQ ;
Zahn, M .
PROCEEDINGS OF THE IEEE, 2004, 92 (05) :808-845
[8]  
Prudenziati M., 1994, HDB SENSORS ACTUATOR
[9]  
SCHINTKE S, 2001, PHYS REV LETT, V87
[10]   Radiation damage in scintillating crystals [J].
Zhu, RY .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 413 (2-3) :297-311