Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem

被引:70
作者
Froimson, Mark I.
Garino, Jonathan
Machenaud, Alan
Vidalain, J. P.
机构
[1] Cleveland Clin Fdn, Dept Orthopaed Surg, Cleveland, OH 44195 USA
[2] Univ Penn, Dept Orthopaed Surg, Philadelphia, PA 19104 USA
[3] Clin Du Lac, Annecy, France
关键词
hip; arthroplasty; hydroxyapatite; follow-up;
D O I
10.1016/j.arth.2006.03.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The performance of, and periprosthetic bone response to, a tapered, titanium (Ti6Al4V), hydroxyapatite-coated femoral hip prosthesis was evaluated at minimum of 10 years of follow-up. Data were prospectively collected on 147 consecutive primary hip arthroplasties performed in 133 patients by a single surgeon during a 2-year interval. Clinical and radiographic analyses of 96 hips in 86 patients were independently performed by 2 surgeons who were not involved in the care of these patients. There were no cases of aseptic loosening of the femoral component. Subsidence and stress shielding occurred in 5% and 2% of cases, respectively, and was not clinically significant. In all 15 hips that required revision of the acetabular component, the femoral component was found to be well fixed, without any occurrence of distal osteolysis. This femoral design provided reliable osseointegration that was durable at a mean of 11.5 years of follow-up.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 33 条
  • [1] Charnley total hip arthroplasty with cement - Minimum twenty-five-year follow-up
    Callaghan, JJ
    Albright, JC
    Goetz, DD
    Olejniczak, JP
    Johnston, RC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) : 487 - 497
  • [2] Hydroxyapatite in total hip arthroplasty -: Clinical results and critical issues
    Capello, WN
    D 'Antonio, JA
    Manley, MT
    Feinberg, JR
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) : 200 - 211
  • [3] D'Antonio JA, 2001, CLIN ORTHOP RELAT R, P101
  • [4] THE EFFECT OF OPERATIVE FIT AND HYDROXYAPATITE COATING ON THE MECHANICAL AND BIOLOGICAL RESPONSE TO POROUS IMPLANTS
    DALTON, JE
    COOK, SD
    THOMAS, KA
    KAY, JF
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (01) : 97 - 110
  • [5] FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS
    DAUBIGNE, RM
    POSTEL, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) : 451 - 475
  • [6] Radiological and survival comparison of four methods of fixation of a proximal femoral stem
    Donnelly, WJ
    Kobayashi, A
    Freeman, MAR
    Chin, TW
    Yeo, H
    West, M
    Scott, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03): : 351 - 360
  • [7] THE CEMENT MANTLE IN TOTAL HIP-ARTHROPLASTY - ANALYSIS OF LONG-TERM RADIOGRAPHIC RESULTS
    EBRAMZADEH, E
    SARMIENTO, A
    MCKELLOP, HA
    LLINAS, A
    GOGAN, W
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (01) : 77 - 87
  • [8] Long-term radiographic changes in cemented total hip arthroplasty with six designs of femoral components
    Ebramzadeh, E
    Normand, PL
    Sangiorgio, SN
    Llinás, A
    Gruen, TA
    McKellop, HA
    Sarmiento, A
    [J]. BIOMATERIALS, 2003, 24 (19) : 3351 - 3363
  • [9] GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17
  • [10] The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups -: From the Norwegian Arthroplasty Register
    Havelin, LI
    Espehaug, B
    Engesæter, LB
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (06): : 839 - 845