Corneal Power Measurement With the Dual Scheimpflug-Placido Topographer After Myopic Excimer Laser Surgery

被引:9
作者
Pan, Chao [1 ]
Hua, Yanjun [2 ]
Huang, Jinhai [3 ,4 ]
Tan, Weina [1 ]
Lu, Weicong [3 ,4 ]
Wang, Qinmei [3 ,4 ]
机构
[1] Wuhan Aier Eye Hosp, Wuhan, Hubei Province, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Ophthalmol, Affiliated Peoples Hosp 6, Shanghai 200030, Peoples R China
[3] Wenzhou Med Univ, Key Lab Vis Sci, Minist Hlth Peoples Republ China, Sch Optometry & Ophthalmol, Wenzhou, Zhejiang, Peoples R China
[4] Wenzhou Med Univ, Key Lab Vis Sci, Minist Hlth Peoples Republ China, Hosp Eye, Wenzhou, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; PHOTOREFRACTIVE KERATECTOMY; REFRACTIVE SURGERY; SIMULATED KERATOMETRY; CATARACT-SURGERY; CAMERA; EYES; PENTACAM;
D O I
10.3928/1081597X-20160106-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the ability of the Sirius Scheimpflug-Placido Topographer (Costruzione Strumenti Oftalmici, Florence, Italy) in predicting corneal power in eyes with previous myopic corneal refractive surgery. METHODS: The following corneal refractive power measurements were obtained with Sirius in 38 eyes with prior myopic excimer laser surgery: simulated keratometry (SimK), true net power based on the Gaussian optical formula (TNP), and the mean pupil power (MPP) calculated by ray tracing within the diameter of the entrance pupil range from 2.5 to 6 mm. These values, along with the corresponding keratometric value, which was based on the equation that converted the MPP within 4.5-mm entrance pupil diameter to a keratometric reading in 75 myopic eyes, were compared using the clinical history method. RESULTS: SimK significantly overestimated corneal power by 0.67 +/- 0.52 diopters (D), whereas TNP significantly underestimated corneal power by -1.05 +/- 0.48 D. The only measurements that showed no statistically significant difference by the clinical history method were the 5 mm MPP, 5.5 mm MPP, and K-MPP4.5POST, and the 95% limits of agreement (LOA) were -1.10 to 0.62, -0.91 to 0.89, and -0.67 to 1.05 D, respectively. CONCLUSIONS: The Sirius Scheimpflug-Placido Topographer is an alternative method of measuring corneal power in eyes with previous corneal refractive surgery for myopia when preoperative data are not available. The best options seem to be the 5 mm MPP, 5.5 mm MPP, and the keratometric reading calculated from the regression formula.
引用
收藏
页码:182 / +
页数:6
相关论文
共 20 条
[1]   Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula [J].
Borasio, Edmondo ;
Stevens, Julian ;
Smith, Guy T. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2004-2014
[2]  
Buzard KA, 1989, J Refract Surg, V5, P202
[3]   Determining corneal power using Pentacam after myopic photorefractive keratectomy [J].
Falavarjani, Khalil Ghasemi ;
Hashemi, Masih ;
Joshaghani, Mahmoud ;
Azadi, Pejvak ;
Ghaempanah, Mohammad J. ;
Aghai, Gholam H. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (04) :341-345
[4]   Assessing the corneal power change after refractive surgery using Scheimpflug imaging [J].
Gyldenkerne, Anders ;
Ivarsen, Anders ;
Hjortdal, Jesper O. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2015, 35 (03) :299-307
[5]  
HOFFER KJ, 1995, J REFRACT SURG, V11, P490
[6]   New Scheimpflug camera device in measuring corneal power changes after myopic laser refractive surgery [J].
Lanza, Michele ;
Iaccarino, Stefania ;
Cennamo, Michela ;
Lanza, Alessandro ;
Coen, Giovanni .
CONTACT LENS & ANTERIOR EYE, 2015, 38 (02) :115-119
[7]   Comparison of Keratometric Changes After Myopic Ablation: Ray Tracing Versus Simulated Keratometry [J].
Mello, Glauco Reggiani ;
Roberts, Cynthia J. ;
Smadja, David ;
Serpe, Crislaine C. ;
Krueger, Ronald R. ;
Santhiago, Marcony R. .
JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (09) :604-610
[8]   Evaluation of the Pentacam Ray Tracing Method for the Measurement of Central Corneal Power After Myopic Photorefractive Keratectomy [J].
Oh, Jong-Hyun ;
Kim, Sung Hyun ;
Chuck, Roy S. ;
Park, Choul Yong .
CORNEA, 2014, 33 (03) :261-265
[9]   Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery [J].
Savini, Giacomo ;
Barboni, Piero ;
Profazio, Vincenzo ;
Zanini, Maurizio ;
Hoffer, Kenneth J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05) :809-813
[10]   Corneal ray tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery [J].
Savini, Giacomo ;
Calossi, Antonio ;
Camellin, Massimo ;
Carones, Francesco ;
Fantozzi, Marco ;
Hoffer, Kenneth J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07) :1109-1115