Optimization and validation of a LC-HRMS method for aflatoxins determination in urine samples

被引:12
作者
Debegnach, Francesca [1 ]
Brera, Carlo [1 ]
Mazzilli, Gianmarco [1 ]
Sonego, Elisa [1 ]
Buiarelli, Francesca [2 ]
Ferri, Fulvio [3 ]
Rossi, Paolo Giorgi [4 ]
Collini, Giorgia [4 ]
De Santis, Barbara [1 ]
机构
[1] Ist Super Sanita, Reparto Sicurezza Chim Alimenti, Viale Regina Elena 299, I-00161 Rome, Italy
[2] Sapienza Univ Roma, Dipartimento Chim, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[3] SPSAL AUSL, Serv Prevenz Sicurezza Ambienti Lavoro, Via Giovanni Amendola 2, I-42122 Reggio Emilia, Italy
[4] AUSL IRCCS, Serv Epidemiol, Via Giovanni Amendola 2, I-42122 Reggio Emilia, Italy
关键词
Biomonitoring; Biomarker; Mycotoxin; Aflatoxin; Metabolites; LC-Orbitrap; LC-HRMS; OCCUPATIONAL-EXPOSURE; BIOMARKERS; MYCOTOXINS; WORKERS; CANCER; WHEAT;
D O I
10.1007/s12550-020-00389-6
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Mycotoxins' exposure by inhalation and/or dermal contact can occur in different branches of industry especially where heavily dusty settings are present and the handling of dusty commodities is performed. This study aims to explore the possible contribution of the occupational exposure to aflatoxins by analysing urine samples for the presence of aflatoxins B-1 and M-1 and aflatoxin B-1-N-7-guanine adduct. The study was conducted in 2017 on two groups of volunteers, the workers group, composed by personnel employed in an Italian feed plant (n = 32), and a control group (n = 29), composed by the administrative employees of the same feed plant; a total of 120 urine samples were collected and analysed. A screening method and a quantitative method with high-resolution mass spectrometry determination were developed and fully validated. Limits of detections were 0.8 and 1.5 pg/mL(urine) for aflatoxin B-1 and M-1, respectively. No quantitative determination was possible for the adduct aflatoxin B-1-N-7-guanine. Aflatoxin B-1 and its adduct were not detected in the analysed samples, and aflatoxin M-1, instead, was found in 14 samples (12%) within the range 1.9-10.5 pg/mL(urine). Only one sample showed a value above the limit of quantification (10.5 pg/mL(urine)). The absence of a statistical difference between the mean values for workers and the control group which were compared suggests that in this specific setting, no professional exposure occurs. Furthermore, considering the very low level of aflatoxin M-1 in the collected urine samples, the contribution from the diet to the overall exposure is to be considered negligible.
引用
收藏
页码:257 / 266
页数:10
相关论文
共 50 条
[31]   Development and validation of a LC-MS/MS method for the simultaneous determination of aflatoxins, dyes and pesticides in spices [J].
Ferrer Amate, C. ;
Unterluggauer, H. ;
Fischer, R. J. ;
Fernandez-Alba, A. R. ;
Masselter, S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (01) :93-107
[32]   Validation of a dual LC-HRMS platform for clinical metabolic diagnosis in serum, bridging quantitative analysis and untargeted metabolomics [J].
Gertsman, Ilya ;
Gangoiti, Jon A. ;
Barshop, Bruce A. .
METABOLOMICS, 2014, 10 (02) :312-323
[33]   Predictive Methodology for Selecting the "Fit-for-Purpose" LC-HRMS Method for Quality Assessment in Peptide Synthesis [J].
Ingle, Pavan ;
Chandrasekar, Naveen ;
Kumar, Sumit ;
Apparao, Cherukuri Venkata ;
Sahu, Bichismita ;
Shah, Ravi P. .
ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2024, 29 (01) :137-145
[34]   Antibody-free LC-HRMS/MS method for simultaneous quantification of NGAL, CRP and SAA in serum from sepsis patients [J].
Derbez-Morin, Maxence ;
Delatour, Vincent ;
Fenaille, Francois ;
Perrot, Catherine ;
Dupuy, Anne-Marie ;
Boeuf, Amandine ;
Becher, Francois .
JOURNAL OF PROTEOMICS, 2025, 314
[35]   Development of an analytical method to assess the occupational health risk of therapeutic monoclonal antibodies using LC-HRMS [J].
Lars M. H. Reinders ;
Martin D. Klassen ;
Martin Jaeger ;
Thorsten Teutenberg ;
Jochen Tuerk .
Analytical and Bioanalytical Chemistry, 2018, 410 :2829-2836
[36]   Optimization of LC method for the determination of testosterone and epitestosterone in urine samples in view of biomedical studies and anti-doping research studies [J].
Konieczna, Lucyna ;
Plenis, Alina ;
Oledzka, Ilona ;
Kowalski, Piotr ;
Baczek, Tomasz .
TALANTA, 2011, 83 (03) :804-814
[37]   Development of an analytical method to assess the occupational health risk of therapeutic monoclonal antibodies using LC-HRMS [J].
Reinders, Lars M. H. ;
Klassen, Martin D. ;
Jaeger, Martin ;
Teutenberg, Thorsten ;
Tuerk, Jochen .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (11) :2829-2836
[38]   Per- and polyfluoroalkyl substances in food and beverages: determination by LC-HRMS and occurrence in products from the Belgian market [J].
Van Leeuw, Virginie ;
Malysheva, Svetlana V. ;
Fosseprez, Guillaume ;
Murphy, Adrien ;
El Amraoui Aarab, Chaymae ;
Andjelkovic, Mirjana ;
Waegeneers, Nadia ;
Van Hoeck, Els ;
Joly, Laure .
Chemosphere, 2024, 366
[39]   Development of an LC-MS/MS method for the determination of multiple mycotoxins in human urine [J].
Chen, Mobing ;
Liu, Wei ;
Xiang, Ping ;
Xu, Linhao ;
Tang, Yiling ;
Kong, Ran ;
Yang, Shuo ;
Yan, Hui ;
Di, Bin .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2023, 40 (07) :917-927
[40]   Polyphenols of white lupin ( Lupinus albus L.) seeds cultivated in Southern Italy by a LC-HRMS method [J].
Cammilleri, Gaetano ;
Calabrese, Vittorio ;
Pantano, Licia ;
Brunone, Mariagrazia ;
Galluzzo, Francesco Giuseppe ;
Pulvirenti, Andrea ;
Fritsch, Tilman ;
Bongiorno, Carmelo ;
Macaluso, Andrea ;
Ferrantelli, Vincenzo .
NATURAL PRODUCT RESEARCH, 2024, 38 (16) :2864-2868